VIOX VM6LY Series Thermomagnetic Earth-Leakage MCCB / ELCB (125A–1250A)

VIOX VM6LY Series Thermomagnetic Leakage MCCB (ELCB) integrates overload, short-circuit (up to 65 kA Icu), and electronic residual-current protection (50–1000 mA adjustable, AC type) across 7 frames from 125 A to 1250 A (2P/3P/4P, AC 230/400 V), with optional leakage-alarm-without-trip and Modbus protocol.

Frame Range
125–1250 A (7 Frames)
残留感度
50–1000 mA (4-Gear Adjustable)
Max Breaking (400V)
Up to 65 kA Icu / 50 kA Ics
Smart Options
Alarm w/o Trip · Modbus RTU

概要

The VIOX VM6LY Series combines thermomagnetic overload/short-circuit protection with an integrated electronic residual-current (earth-leakage) release in one compact molded case. Spanning 7 frames from 125 A to 1250 A (16 A–1250 A rated current, 2P/3P/4P, AC 230/400 V, Ui 1000 V, Uimp 8 kV), VM6LY protects commercial sub-distribution panels, construction sites, and industrial feeders against electric shock and earth-fault fire hazards—with optional 4-gear adjustable IΔn (50–1000 mA), leakage alarm without trip (Code II), and Modbus communication (Code T).

特徴

  • Integrated thermomagnetic overcurrent + electronic earth-leakage protection in a standard VM6 footprint.
  • 7 frames: VM6LY-125, 160, 250, 400, 630, 800, and 1250 A (2P/3P/4P on 125–160 A; 3P/4P on 250–1250 A).
  • Field-selectable 4-gear residual operating current: 50, 100, 200, 300, 500, 800, and 1000 mA (AC type).
  • High breaking capacity up to 65 kA Icu / 50 kA Ics (400–1250 A H) with IΔm up to 16.25 kA.
  • Optional additional functions: Leakage alarm with trip (Code I), Leakage alarm without trip (Code II), and Modbus communication (Code T).
  • Compatible with electric motor operators, rotary handles, plug-in/draw-out bases, and internal codes 00–78.

モデル

Frame SeriesRated Current In (A)Breaking TiersポールMax Icu / Ics (400 V AC)
VM6LY-12516–125 AC, S, M, H2P、3P、4P35 kA / 35 kA
VM6LY-16016–160 AC, S, M, H2P、3P、4P35 kA / 35 kA
VM6LY-250100–250 AC, S, M, H3P, 4P50 kA / 35 kA
VM6LY-400250, 315, 350, 400 AM, H3P, 4P65 kA / 42 kA
VM6LY-630400, 500, 630 AM, H3P, 4P65 kA / 50 kA
VM6LY-800500, 630, 700, 800 AM, H3P, 4P65 kA / 50 kA
VM6LY-1250900, 1000, 1250 AM, H3P, 4P65 kA / 50 kA

仕様

Electrical & Residual-Current Data

Frame & TiersIcs / Icu (400 V)IΔmIΔn (mA) & Type
VM6LY-125 C/S/M/H3–35 kA / 5–35 kA12.5 kA50–1000 mA · AC type
VM6LY-160 C/S/M/H10–35 kA / 15–35 kA12.5 kA50–1000 mA · AC type
VM6LY-250 C/S/M/H10–35 kA / 15–50 kA12.5 kA50–1000 mA · AC type
VM6LY-400 M/H35–42 kA / 50–65 kA16.25 kA50–1000 mA (4 adjustable gears) · AC
VM6LY-630 / 800 / 1250 M/H35–50 kA / 50–65 kA16.25 kA50–1000 mA (4 adjustable gears) · AC

Outline Dimensions (mm)

フレームポールWidth W (mm)Length L (mm)Height Cover / Handle (mm)
VM6LY-1252P / 3P / 4P50 / 75 / 10013068 / 94.5
VM6LY-1602P / 3P / 4P60 / 90 / 12015568 / 94
VM6LY-2503P / 4P105 / 14016568 / 96
VM6LY-400 / 6303P / 4P140 / 184257103 / 152
VM6LY-800 / 12503P / 4P210 / 280275.5103 / 152

External Accessories Compatibility

アクセサリSupported Frames & Poles
Electric Motor Operation3P, 4P
Manual Rotary Handle (ZY1/ZF1/ZY2/ZF2/Z3)3P, 4P
Extension Copper Bar (P)3P, 4P
機械的連動3P, 4P (up to 800 A)
Plug-in Front / Back Panel (Z2Q/Z2H/Z3Q/Z3H)3P, 4P (up to 800 A)
Draw-out Back-Panel (DR)400 / 630 / 800 A (3P only)

セレクションガイド

コード位置意味Catalog Value or Options
VM6LYシリーズThermomagnetic earth-leakage MCCB (ELCB)
125–1250フレーム電流125, 160, 250, 400, 630, 800, 1250 A
C / S / M / HBreaking tierC/S/M/H (125–250 A); M/H (400–1250 A)
I / II / T付加機能I: Leakage alarm w/ trip · II: Leakage alarm w/o trip · T: Modbus communication
2 / 3 / 4ポール2P (125/160 A), 3P, 4P (Neutral Types A, B, C, D)
00–78Internal accessory code00 None · 08 Alarm · 10 Shunt · 18 Shunt+Alarm · 20/27 Aux · 28/29 Aux+Alarm · 30 UVT · 38 UVT+Alarm · 40/41/48 Shunt+Aux · 50 Shunt+UVT · 60–69 Multi-Aux · 70–78 UVT+Aux (DC 24/110/220 V, AC 230/400 V)

1. Select IΔn Sensitivity

Choose 50–100 mA for enhanced shock protection or 300–1000 mA for upstream fire protection and selectivity.

2. Trip vs Alarm Mode

Pick standard trip, Code I (alarm + trip), or Code II (alarm without trip) for critical feeders.

3. Match Upstream Selectivity

Coordinate VM6LY (100–500 mA) upstream of downstream 30 mA RCBOs or RCCBs.

4. Add Remote Telemetry

Specify Code T (Modbus RTU) to report leakage status to BMS or SCADA systems.

インストール

  • Press the front TEST button monthly after commissioning to verify electronic residual-current release operation.
  • Keep neutral conductors downstream of the VM6LY isolated from PE/ground to prevent nuisance leakage tripping.
  • Coordinate with downstream VIOX RCBO そして RCCB for selective earth-fault protection.
  • View the full VIOX MCCB lineup or compare with electronic LCD leakage VM6ELY.

よくあるご質問

What residual-current settings does VM6LY support?

VM6LY offers 4-gear field-adjustable sensitivity across 50, 100, 200, 300, 500, 800, and 1000 mA (AC type) so one breaker coordinates cleanly with downstream 30 mA devices.

Can VM6LY alarm on earth leakage without tripping the feeder?

Yes. Specify additional function code II (leakage alarm without trip) for critical feeders where immediate alarm notification is required without power interruption.

Does VM6LY support Modbus communication?

Yes. Specify code T to integrate Modbus RTU monitoring into panel SCADA or building management systems.

What is the maximum frame size and breaking capacity of VM6LY?

VM6LY scales up to 1250 A with 65 kA Icu / 50 kA Ics and 16.25 kA IΔm at AC 400 V.

Is VM6LY available in 2P, 3P, and 4P?

2P is available on VM6LY-125 and VM6LY-160; 3P and 4P (Neutral Types A–D) are available across all 7 frames up to 1250 A.

What is the difference between VM6LY and VM6ELY?

VM6LY uses a thermomagnetic overcurrent release (Class A) with electronic leakage detection, whereas VM6ELY uses a full electronic Class B trip unit with LCD display and Icw 10–20 kA/1s.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

製品の見積もりが必要ですか?
私たちと一緒に作り上げましょう。.

製品モデル、技術定格、数量、およびOEM要件をお送りください。当社のチームがお客様の用途を確認し、1営業日以内に回答いたします。.

見積依頼