Panoramica
The VIOX VM6LY Series combines thermomagnetic overload/short-circuit protection with an integrated electronic residual-current (earth-leakage) release in one compact molded case. Spanning 7 frames from 125 A to 1250 A (16 A–1250 A rated current, 2P/3P/4P, AC 230/400 V, Ui 1000 V, Uimp 8 kV), VM6LY protects commercial sub-distribution panels, construction sites, and industrial feeders against electric shock and earth-fault fire hazards—with optional 4-gear adjustable IΔn (50–1000 mA), leakage alarm without trip (Code II), and Modbus communication (Code T).
Caratteristiche
- Integrated thermomagnetic overcurrent + electronic earth-leakage protection in a standard VM6 footprint.
- 7 frames: VM6LY-125, 160, 250, 400, 630, 800, and 1250 A (2P/3P/4P on 125–160 A; 3P/4P on 250–1250 A).
- Field-selectable 4-gear residual operating current: 50, 100, 200, 300, 500, 800, and 1000 mA (AC type).
- High breaking capacity up to 65 kA Icu / 50 kA Ics (400–1250 A H) with IΔm up to 16.25 kA.
- Optional additional functions: Leakage alarm with trip (Code I), Leakage alarm without trip (Code II), and Modbus communication (Code T).
- Compatible with electric motor operators, rotary handles, plug-in/draw-out bases, and internal codes 00–78.
Modelli
| Frame Series | Rated Current In (A) | Breaking Tiers | Poli | Max Icu / Ics (400 V AC) |
|---|---|---|---|---|
| VM6LY-125 | 16–125 A | C, S, M, H | 2P, 3P, 4P | 35 kA / 35 kA |
| VM6LY-160 | 16–160 A | C, S, M, H | 2P, 3P, 4P | 35 kA / 35 kA |
| VM6LY-250 | 100–250 A | C, S, M, H | 3P, 4P | 50 kA / 35 kA |
| VM6LY-400 | 250, 315, 350, 400 A | M, H | 3P, 4P | 65 kA / 42 kA |
| VM6LY-630 | 400, 500, 630 A | M, H | 3P, 4P | 65 kA / 50 kA |
| VM6LY-800 | 500, 630, 700, 800 A | M, H | 3P, 4P | 65 kA / 50 kA |
| VM6LY-1250 | 900, 1000, 1250 A | M, H | 3P, 4P | 65 kA / 50 kA |
Specifiche tecniche
Electrical & Residual-Current Data
| Frame & Tiers | Ics / Icu (400 V) | IΔm | IΔn (mA) & Type |
|---|---|---|---|
| VM6LY-125 C/S/M/H | 3–35 kA / 5–35 kA | 12.5 kA | 50–1000 mA · AC type |
| VM6LY-160 C/S/M/H | 10–35 kA / 15–35 kA | 12.5 kA | 50–1000 mA · AC type |
| VM6LY-250 C/S/M/H | 10–35 kA / 15–50 kA | 12.5 kA | 50–1000 mA · AC type |
| VM6LY-400 M/H | 35–42 kA / 50–65 kA | 16.25 kA | 50–1000 mA (4 adjustable gears) · AC |
| VM6LY-630 / 800 / 1250 M/H | 35–50 kA / 50–65 kA | 16.25 kA | 50–1000 mA (4 adjustable gears) · AC |
Outline Dimensions (mm)
| Telaio | Poli | Width W (mm) | Length L (mm) | Height Cover / Handle (mm) |
|---|---|---|---|---|
| VM6LY-125 | 2P / 3P / 4P | 50 / 75 / 100 | 130 | 68 / 94.5 |
| VM6LY-160 | 2P / 3P / 4P | 60 / 90 / 120 | 155 | 68 / 94 |
| VM6LY-250 | 3P / 4P | 105 / 140 | 165 | 68 / 96 |
| VM6LY-400 / 630 | 3P / 4P | 140 / 184 | 257 | 103 / 152 |
| VM6LY-800 / 1250 | 3P / 4P | 210 / 280 | 275.5 | 103 / 152 |
External Accessories Compatibility
| Accessorio | Supported Frames & Poles |
|---|---|
| Electric Motor Operation | 3P, 4P |
| Manual Rotary Handle (ZY1/ZF1/ZY2/ZF2/Z3) | 3P, 4P |
| Extension Copper Bar (P) | 3P, 4P |
| Interblocco meccanico | 3P, 4P (up to 800 A) |
| Plug-in Front / Back Panel (Z2Q/Z2H/Z3Q/Z3H) | 3P, 4P (up to 800 A) |
| Draw-out Back-Panel (DR) | 400 / 630 / 800 A (3P only) |
Guida alla selezione
| Posizione codice | Significato | Catalog Value or Options |
|---|---|---|
| VM6LY | Serie | Thermomagnetic earth-leakage MCCB (ELCB) |
| 125–1250 | Corrente di telaio | 125, 160, 250, 400, 630, 800, 1250 A |
| C / S / M / H | Breaking tier | C/S/M/H (125–250 A); M/H (400–1250 A) |
| I / II / T | Funzione aggiuntiva | I: Leakage alarm w/ trip · II: Leakage alarm w/o trip · T: Modbus communication |
| 2 / 3 / 4 | Poli | 2P (125/160 A), 3P, 4P (Neutral Types A, B, C, D) |
| 00–78 | Internal accessory code | 00 None · 08 Alarm · 10 Shunt · 18 Shunt+Alarm · 20/27 Aux · 28/29 Aux+Alarm · 30 UVT · 38 UVT+Alarm · 40/41/48 Shunt+Aux · 50 Shunt+UVT · 60–69 Multi-Aux · 70–78 UVT+Aux (DC 24/110/220 V, AC 230/400 V) |
1. Select IΔn Sensitivity
Choose 50–100 mA for enhanced shock protection or 300–1000 mA for upstream fire protection and selectivity.
2. Trip vs Alarm Mode
Pick standard trip, Code I (alarm + trip), or Code II (alarm without trip) for critical feeders.
3. Match Upstream Selectivity
Coordinate VM6LY (100–500 mA) upstream of downstream 30 mA RCBOs or RCCBs.
4. Add Remote Telemetry
Specify Code T (Modbus RTU) to report leakage status to BMS or SCADA systems.
Installazione
- Press the front TEST button monthly after commissioning to verify electronic residual-current release operation.
- Keep neutral conductors downstream of the VM6LY isolated from PE/ground to prevent nuisance leakage tripping.
- Coordinate with downstream RCBO VIOX e RCCB for selective earth-fault protection.
- View the full VIOX MCCB lineup or compare with electronic LCD leakage VM6ELY.
FAQ
What residual-current settings does VM6LY support?
VM6LY offers 4-gear field-adjustable sensitivity across 50, 100, 200, 300, 500, 800, and 1000 mA (AC type) so one breaker coordinates cleanly with downstream 30 mA devices.
Can VM6LY alarm on earth leakage without tripping the feeder?
Yes. Specify additional function code II (leakage alarm without trip) for critical feeders where immediate alarm notification is required without power interruption.
Does VM6LY support Modbus communication?
Yes. Specify code T to integrate Modbus RTU monitoring into panel SCADA or building management systems.
What is the maximum frame size and breaking capacity of VM6LY?
VM6LY scales up to 1250 A with 65 kA Icu / 50 kA Ics and 16.25 kA IΔm at AC 400 V.
Is VM6LY available in 2P, 3P, and 4P?
2P is available on VM6LY-125 and VM6LY-160; 3P and 4P (Neutral Types A–D) are available across all 7 frames up to 1250 A.
What is the difference between VM6LY and VM6ELY?
VM6LY uses a thermomagnetic overcurrent release (Class A) with electronic leakage detection, whereas VM6ELY uses a full electronic Class B trip unit with LCD display and Icw 10–20 kA/1s.