VIOX ELECTRIC
اللغة

VIOX VM6LY Series Thermomagnetic Earth-Leakage MCCB / ELCB (125A–1250A)

VIOX VM6LY Series Thermomagnetic Leakage MCCB (ELCB) integrates overload, short-circuit (up to 65 kA Icu), and electronic residual-current protection (50–1000 mA adjustable, AC type) across 7 frames from 125 A to 1250 A (2P/3P/4P, AC 230/400 V), with optional leakage-alarm-without-trip and Modbus protocol.

Frame Range
125–1250 A (7 Frames)
حساسية التيار المتبقي
50–1000 mA (4-Gear Adjustable)
Max Breaking (400V)
Up to 65 kA Icu / 50 kA Ics
Smart Options
Alarm w/o Trip · Modbus RTU

نظرة عامة

The VIOX VM6LY Series combines thermomagnetic overload/short-circuit protection with an integrated electronic residual-current (earth-leakage) release in one compact molded case. Spanning 7 frames from 125 A to 1250 A (16 A–1250 A rated current, 2P/3P/4P, AC 230/400 V, Ui 1000 V, Uimp 8 kV), VM6LY protects commercial sub-distribution panels, construction sites, and industrial feeders against electric shock and earth-fault fire hazards—with optional 4-gear adjustable IΔn (50–1000 mA), leakage alarm without trip (Code II), and Modbus communication (Code T).

الميزات

  • Integrated thermomagnetic overcurrent + electronic earth-leakage protection in a standard VM6 footprint.
  • 7 frames: VM6LY-125, 160, 250, 400, 630, 800, and 1250 A (2P/3P/4P on 125–160 A; 3P/4P on 250–1250 A).
  • Field-selectable 4-gear residual operating current: 50, 100, 200, 300, 500, 800, and 1000 mA (AC type).
  • High breaking capacity up to 65 kA Icu / 50 kA Ics (400–1250 A H) with IΔm up to 16.25 kA.
  • Optional additional functions: Leakage alarm with trip (Code I), Leakage alarm without trip (Code II), and Modbus communication (Code T).
  • Compatible with electric motor operators, rotary handles, plug-in/draw-out bases, and internal codes 00–78.

النماذج

Frame SeriesRated Current In (A)Breaking TiersالقطبينMax Icu / Ics (400 V AC)
VM6LY-12516–125 AC, S, M, H2P، 3P، 4P35 kA / 35 kA
VM6LY-16016–160 AC, S, M, H2P، 3P، 4P35 kA / 35 kA
VM6LY-250100–250 AC, S, M, H3P, 4P50 kA / 35 kA
VM6LY-400250, 315, 350, 400 AM, H3P, 4P65 kA / 42 kA
VM6LY-630400, 500, 630 AM, H3P, 4P65 kA / 50 kA
VM6LY-800500, 630, 700, 800 AM, H3P, 4P65 kA / 50 kA
VM6LY-1250900, 1000, 1250 AM, H3P, 4P65 kA / 50 kA

المواصفات

Electrical & Residual-Current Data

Frame & TiersIcs / Icu (400 V)IΔmIΔn (mA) & Type
VM6LY-125 C/S/M/H3–35 kA / 5–35 kA12.5 kA50–1000 mA · AC type
VM6LY-160 C/S/M/H10–35 kA / 15–35 kA12.5 kA50–1000 mA · AC type
VM6LY-250 C/S/M/H10–35 kA / 15–50 kA12.5 kA50–1000 mA · AC type
VM6LY-400 M/H35–42 kA / 50–65 kA16.25 kA50–1000 mA (4 adjustable gears) · AC
VM6LY-630 / 800 / 1250 M/H35–50 kA / 50–65 kA16.25 kA50–1000 mA (4 adjustable gears) · AC

Outline Dimensions (mm)

إطارالقطبينWidth W (mm)Length L (mm)Height Cover / Handle (mm)
VM6LY-1252P / 3P / 4P50 / 75 / 10013068 / 94.5
VM6LY-1602P / 3P / 4P60 / 90 / 12015568 / 94
VM6LY-2503P / 4P105 / 14016568 / 96
VM6LY-400 / 6303P / 4P140 / 184257103 / 152
VM6LY-800 / 12503P / 4P210 / 280275.5103 / 152

External Accessories Compatibility

ملحقSupported Frames & Poles
Electric Motor Operation3P, 4P
Manual Rotary Handle (ZY1/ZF1/ZY2/ZF2/Z3)3P, 4P
Extension Copper Bar (P)3P, 4P
التشابك الميكانيكي3P, 4P (up to 800 A)
Plug-in Front / Back Panel (Z2Q/Z2H/Z3Q/Z3H)3P, 4P (up to 800 A)
Draw-out Back-Panel (DR)400 / 630 / 800 A (3P only)

دليل الاختيار

موقع الكودالمعنىCatalog Value or Options
VM6LYالسلسلةThermomagnetic earth-leakage MCCB (ELCB)
125–1250تيار الإطار125, 160, 250, 400, 630, 800, 1250 A
C / S / M / HBreaking tierC/S/M/H (125–250 A); M/H (400–1250 A)
I / II / Tوظيفة إضافيةI: Leakage alarm w/ trip · II: Leakage alarm w/o trip · T: Modbus communication
2 / 3 / 4القطبين2P (125/160 A), 3P, 4P (Neutral Types A, B, C, D)
00–78Internal accessory code00 None · 08 Alarm · 10 Shunt · 18 Shunt+Alarm · 20/27 Aux · 28/29 Aux+Alarm · 30 UVT · 38 UVT+Alarm · 40/41/48 Shunt+Aux · 50 Shunt+UVT · 60–69 Multi-Aux · 70–78 UVT+Aux (DC 24/110/220 V, AC 230/400 V)

1. Select IΔn Sensitivity

Choose 50–100 mA for enhanced shock protection or 300–1000 mA for upstream fire protection and selectivity.

2. Trip vs Alarm Mode

Pick standard trip, Code I (alarm + trip), or Code II (alarm without trip) for critical feeders.

3. Match Upstream Selectivity

Coordinate VM6LY (100–500 mA) upstream of downstream 30 mA RCBOs or RCCBs.

4. Add Remote Telemetry

Specify Code T (Modbus RTU) to report leakage status to BMS or SCADA systems.

التركيب

الأسئلة الشائعة

What residual-current settings does VM6LY support?

VM6LY offers 4-gear field-adjustable sensitivity across 50, 100, 200, 300, 500, 800, and 1000 mA (AC type) so one breaker coordinates cleanly with downstream 30 mA devices.

Can VM6LY alarm on earth leakage without tripping the feeder?

Yes. Specify additional function code II (leakage alarm without trip) for critical feeders where immediate alarm notification is required without power interruption.

Does VM6LY support Modbus communication?

Yes. Specify code T to integrate Modbus RTU monitoring into panel SCADA or building management systems.

What is the maximum frame size and breaking capacity of VM6LY?

VM6LY scales up to 1250 A with 65 kA Icu / 50 kA Ics and 16.25 kA IΔm at AC 400 V.

Is VM6LY available in 2P, 3P, and 4P?

2P is available on VM6LY-125 and VM6LY-160; 3P and 4P (Neutral Types A–D) are available across all 7 frames up to 1250 A.

What is the difference between VM6LY and VM6ELY?

VM6LY uses a thermomagnetic overcurrent release (Class A) with electronic leakage detection, whereas VM6ELY uses a full electronic Class B trip unit with LCD display and Icw 10–20 kA/1s.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

هل تحتاج إلى عرض سعر للمنتج؟
لنبنيها معاً.

أرسل لنا طراز المنتج، والتقييمات الفنية، والكمية، ومتطلبات الشركة المصنعة للمعدات الأصلية (OEM). سيقوم فريقنا بمراجعة طلبك والرد في غضون يوم عمل واحد.

طلب عرض أسعار