概要
Clear HRC VIOX 690VAC 100A Australia Type Clear HRC Cutout Fuse is designed to ensure a secure connection and low contact resistance throughout and is typically used to protect the supply to a flat or a dwelling and used as a service head. Glass-reinforced Polyester (DMC) material provides strength, durability, and excellent tracking resistance.
690VAC 100A Australia Type Clear HRC Cutout Fuse
特徴
- High strength
- 高い耐久性
- Excellent tracking resistance
- 100A ampere ratings
- Two wiring options
- CB approved
- Service cutout, household use. Normally used to protect the supply to a flat or a dwelling. Used as a service head
- Secure connection and low contact resistance throughout
仕様
Clear Technical Specifications
| Model / Size | 定格電圧 (V) | 定格電流 (A) | Recommended Fuse Link Model/Size | 全体寸法 | 注 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YR:FG22FW | 415V/500V/690V | 100A | 22×58mm | Refer to Fig.1 | FW: both sides wiring WB: bottom wiring | ||||||||
| YR:FG22WB | |||||||||||||
| YR:FG30FW | 30×57mm | ||||||||||||
| YR:FG30WB | |||||||||||||
Selection & Installation Notes
- Verify system maximum voltage (690VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
- Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
- Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
- Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.
よくあるご質問
What voltage and current ratings does the VIOX 690VAC 100A Australia Type Clear HRC Cutout Fuse support?
This VIOX Clear series is rated for 690VAC with a current rating of 100A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.
Which international standards apply to VIOX 690VAC 100A Australia Type Clear HRC Cutout Fuse?
The Clear series is designed and verified to BS88 / IEC60269 requirements for safe overcurrent and short-circuit protection.
Where is the VIOX 690VAC 100A Australia Type Clear HRC Cutout Fuse typically installed?
It is engineered for low-voltage hrc industrial fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.
Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?
Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.




