The VIOX VOE3-63 miniature circuit breaker provides overload and short-circuit protection for AC 50/60 Hz circuits. It covers rated currents from 6 A to 63 A, C and D tripping curves, and 1P to 4P configurations. Designed for DIN-rail mounting, it supports residential, commercial and industrial power distribution systems and infrequent circuit switching.

Rated Current
6-63 A
Pole Configuration
1P, 2P, 3P, 4P
Tripping Curves
C, D
Rated Voltage
230 V AC (1P); 400 V AC (2P-4P)

Overview

The VOE3-63 is a miniature circuit breaker for overload and short-circuit protection in AC 50/60 Hz electrical circuits. It is available with rated currents from 6 A to 63 A, C or D tripping curves, and 1P, 2P, 3P or 4P configurations. Single-pole versions are rated at 230 V AC, while 2P, 3P and 4P versions are rated at 400 V AC. Designed for DIN-rail mounting, the breaker is intended for residential, commercial and industrial power distribution systems. It can also provide infrequent circuit switching under normal operating conditions.

Features

  • Compliant with IEC 60898.
  • Rated-current options from 6 A to 63 A.
  • C (5-10 In) and D (10-20 In) tripping characteristics.
  • Available in 1P, 2P, 3P and 4P configurations.
  • Ambient operating-temperature range from -5°C to +40°C.
  • Applicable nominal conductor cross-sections from 1 mm² to 16 mm², according to rated current.

Models

Catalog designation Pole configuration Rated voltage
VOE3-63 1P 1P 230 V AC
VOE3-63 2P 2P 400 V AC
VOE3-63 3P 3P 400 V AC
VOE3-63 4P 4P 400 V AC

Specifications

Electrical Data

Parameter Specification
Rated frame current 63 A
Rated current 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Rated frequency 50/60 Hz

Protection Data

Parameter Specification
Protection function Overload and short-circuit protection
C tripping curve 5-10 In
D tripping curve 10-20 In
C curve breaking capacity, 6-32 A 6 kA
C curve breaking capacity, 50-63 A 4 kA
D curve breaking capacity 4 kA

Installation Data

Parameter Specification
Installation DIN-rail mounting
Additional function Infrequent circuit switching

Applicable Conductors

Rated current Nominal conductor cross-section
6 A 1 mm²
10 A 1.5 mm²
16-20 A 2.5 mm²
25 A 4 mm²
32 A 6 mm²
40-50 A 10 mm²
63 A 16 mm²

Environmental and Standards Data

Parameter Specification
Ambient operating temperature -5°C to +40°C
Compliant standard IEC 60898

Selection Guide

Code position Meaning Catalog value or options
VO Enterprise identification VO
E MCB Eco Model E
3 Design serial number 3
60 Shell frame current 60
C / D Tripping curve C or D
Rated-current code Rated current 6 A, 10 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A or 63 A
1P / 2P / 3P / 4P Number of poles 1P, 2P, 3P or 4P

Rated Current

Select one of the listed ratings from 6 A to 63 A according to the circuit rating and protection requirements.

Tripping Curve

Choose the C curve for a 5-10 In instantaneous range or the D curve for a 10-20 In instantaneous range.

Poles and Voltage

Use the 230 V AC 1P configuration or a 400 V AC 2P, 3P or 4P configuration as required by the circuit.

Conductor Size

Match the nominal conductor cross-section to the selected rated current using the applicable-conductor table.

Trip Curves

Ambient temperature Initial condition Test current Operating time Expected result Remarks
30 ± 2°C Cold state 1.13 In t ≥ 1 h No tripping
30 ± 2°C Immediately after the previous test 1.45 In t < 1 h Tripping
30 ± 2°C Cold state 2.55 In 1 s < t < 60 s Tripping In ≤ 32 A; current increased smoothly to the specified value within 5 s
30 ± 2°C Cold state 2.55 In 1 s < t < 120 s Tripping In > 32 A; current increased smoothly to the specified value within 5 s
-5°C to +40°C Cold state 5 In t ≥ 0.1 s No tripping C curve
-5°C to +40°C Cold state 10 In t < 0.1 s Tripping C curve
-5°C to +40°C Cold state 10 In t ≥ 0.1 s No tripping D curve
-5°C to +40°C Cold state 20 In t < 0.1 s Tripping D curve

Applications

  • Residential power distribution systems.
  • Commercial power distribution systems.
  • Industrial power distribution systems.
  • Infrequent switching of electrical circuits under normal operating conditions.

Installation

  • Mount the selected configuration on a DIN rail.
  • Confirm that the pole configuration and rated voltage match the circuit.
  • Use the nominal conductor cross-section specified for the selected rated current.
  • Confirm that the installation environment remains within the listed -5°C to +40°C ambient operating range.

FAQ

What protection does the VOE3-63 provide?

It provides overload and short-circuit protection for AC 50/60 Hz electrical circuits.

Which rated currents and tripping curves are available?

The catalog lists 6, 10, 16, 20, 25, 32, 40, 50 and 63 A ratings with C and D tripping curves.

Which voltage applies to each pole configuration?

The 1P configuration is rated at 230 V AC. The 2P, 3P and 4P configurations are rated at 400 V AC.

How should the nominal conductor cross-section be selected?

Use the catalog conductor table to match the nominal conductor cross-section to the selected rated current.

Can the VOE3-63 be used for circuit switching?

Yes. The catalog states that it can be used for infrequent switching of electrical circuits under normal operating conditions.

Which standard is listed for the VOE3-63?

The catalog lists IEC 60898 as the compliant standard.

Need a Product Quote?
Let’s Build It Together.

Send us the product model, technical ratings, quantity, and OEM requirements. Our team will review your application and respond within one business day.

Request a Quote