概要
The VIOX VM7LE Series is a compact 4-pole (3P+N) electronic residual-current operated circuit breaker combining earth-leakage protection, overcurrent protection, prepaid/cost-control switching, electrical metering, and remote communication in one space-saving frame. Covering 250 A, 400/630 A, and 800 A frames (50 A–800 A, AC 400 V, Ui 1000 V), VM7LE delivers 50–65 kA Icu breaking capacity for utility distribution boxes, commercial sub-metering, and smart-grid feeders.
特徴
- Compact 4P (3P+N) electronic residual-current operated MCCB with front status display and test controls.
- Integrated cost-control function, electrical metering, and remote communication interface.
- High breaking capacity: 50/35 kA (250 A), 50/50 kA (400/630 A), and 65/50 kA (800 A) at AC 400 V.
- Covers 50 A to 800 A across three standardized 4P frames (250 A, 400/630 A, 800 A).
- Up to 7,000 mechanical operations (OFF) and 1,000 electrical operations (ON) on 250 A.
- AC 1000 V rated insulation voltage with electronic automatic release device.
モデル
| モデル | Rated Current In (A) | ポール | Icu / Ics (400 V) | Dimensions b×a×ca (mm) |
|---|---|---|---|---|
| VM7LE-250 | 50–125 A · 100–250 A | 4P (3P+N) | 50 kA / 35 kA | 165 × 140 × 131 |
| VM7LE-400/630 | 160–400 A · 252–630 A | 4P (3P+N) | 50 kA / 50 kA | 257 × 184 × 173 |
| VM7LE-800 | 252–630 A · 320–800 A | 4P (3P+N) | 65 kA / 50 kA | 275.5 × 280 × 169 |
仕様
Electrical & Endurance Data
| パラメータ | VM7LE-250 | VM7LE-400/630 | VM7LE-800 |
|---|---|---|---|
| Rated voltage / Ui | AC 400 V / AC 1000 V | AC 400 V / AC 1000 V | AC 400 V / AC 1000 V |
| Operation cycles (ON / OFF) | 1,000 / 7,000 | 1,000 / 4,000 | 500 / 2,500 |
| Automatic release device | 電子式 | 電子式 | 電子式 |
| Smart functions | Cost control, metering, comm | Cost control, metering, comm | Cost control, metering, comm |
セレクションガイド
| コード位置 | 意味 | Catalog Value or Options |
|---|---|---|
| VM7LE | シリーズ | Electronic residual-current operated circuit breaker with cost control |
| 250 / 400 / 630 / 800 | フレーム電流 | 250 A, 400/630 A, or 800 A |
| 4P (3P+N) | ポール | Four-pole residual-current architecture |
1. Unify Metering & RCD
Replace separate RCCB + MCCB + smart-meter stacks with one compact VM7LE unit.
2. Enable Cost Control
Connect prepaid/utility billing controllers for automated remote connect/disconnect.
3. Match Fault Level
Select 50 kA (250–630 A) or 65 kA (800 A) Icu at AC 400 V.
4. Check Depth Clearance
Allow 131–173 mm cabinet depth for the integrated front controller module.
インストール
よくあるご質問
What functions are integrated inside VM7LE?
VM7LE integrates electronic overcurrent protection, residual-current (earth-leakage) protection, prepaid/cost-control switching, electrical metering, and remote communication.
What current range does VM7LE cover?
From 50 A to 800 A across three 4P (3P+N) frames: VM7LE-250, VM7LE-400/630, and VM7LE-800.
What is the short-circuit breaking capacity of VM7LE?
At AC 400 V: 50/35 kA on 250 A, 50/50 kA on 400/630 A, and 65/50 kA (Icu/Ics) on 800 A.
How compact is VM7LE compared to separate assemblies?
VM7LE-250 measures just 165 × 140 × 131 mm while packing breaker, RCD, metering, and cost-control electronics in one body.
Is VM7LE suitable for utility smart-grid distribution cabinets?
Yes. It is specifically designed for smart transformer feeders, commercial sub-metering, and utility cost-control cabinets.
What is the rated insulation voltage of VM7LE?
AC 1000 V across all three frames.




