VIOX ELECTRIC
Ngôn ngữ

VIOX VM7LE Series Electronic Residual-Current MCCB with Cost Control (250A–800A)

VIOX VM7LE Series 4P (3P+N) Residual-Current Operated Circuit Breaker (250 A, 400/630 A, and 800 A frames; 50 A–800 A; AC 400 V; Ui 1000 V; up to 65 kA Icu / 50 kA Ics) combines electronic residual-current and overcurrent protection with compact cost-control, metering, and remote communication.

Frame Range
250 / 400 / 630 / 800 A (3P+N)
Breaking (400V)
50–65 kA Icu · 35–50 kA Ics
Chức năng tích hợp
Cost Control · Metering · Comm
Release Type
Electronic Residual + Overcurrent

Tổng quan

The VIOX VM7LE Series is a compact 4-pole (3P+N) electronic residual-current operated circuit breaker combining earth-leakage protection, overcurrent protection, prepaid/cost-control switching, electrical metering, and remote communication in one space-saving frame. Covering 250 A, 400/630 A, and 800 A frames (50 A–800 A, AC 400 V, Ui 1000 V), VM7LE delivers 50–65 kA Icu breaking capacity for utility distribution boxes, commercial sub-metering, and smart-grid feeders.

Đặc trưng

  • Compact 4P (3P+N) electronic residual-current operated MCCB with front status display and test controls.
  • Integrated cost-control function, electrical metering, and remote communication interface.
  • High breaking capacity: 50/35 kA (250 A), 50/50 kA (400/630 A), and 65/50 kA (800 A) at AC 400 V.
  • Covers 50 A to 800 A across three standardized 4P frames (250 A, 400/630 A, 800 A).
  • Up to 7,000 mechanical operations (OFF) and 1,000 electrical operations (ON) on 250 A.
  • AC 1000 V rated insulation voltage with electronic automatic release device.

Mô hình

Người mẫuRated Current In (A)CựcIcu / Ics (400 V)Dimensions b×a×ca (mm)
VM7LE-25050–125 A · 100–250 A4P (3P+N)50 kA / 35 kA165 × 140 × 131
VM7LE-400/630160–400 A · 252–630 A4P (3P+N)50 kA / 50 kA257 × 184 × 173
VM7LE-800252–630 A · 320–800 A4P (3P+N)65 kA / 50 kA275.5 × 280 × 169

Thông số kỹ thuật

Electrical & Endurance Data

Tham sốVM7LE-250VM7LE-400/630VM7LE-800
Rated voltage / UiAC 400 V / AC 1000 VAC 400 V / AC 1000 VAC 400 V / AC 1000 V
Operation cycles (ON / OFF)1,000 / 7,0001,000 / 4,000500 / 2,500
Automatic release deviceElectronic typeElectronic typeElectronic type
Smart functionsCost control, metering, commCost control, metering, commCost control, metering, comm

Hướng dẫn lựa chọn

Code PositionÝ nghĩaCatalog Value or Options
VM7LELoạtElectronic residual-current operated circuit breaker with cost control
250 / 400 / 630 / 800Dòng điện khung250 A, 400/630 A, or 800 A
4P (3P+N)CựcFour-pole residual-current architecture

1. Unify Metering & RCD

Replace separate RCCB + MCCB + smart-meter stacks with one compact VM7LE unit.

2. Enable Cost Control

Connect prepaid/utility billing controllers for automated remote connect/disconnect.

3. Match Fault Level

Select 50 kA (250–630 A) or 65 kA (800 A) Icu at AC 400 V.

4. Check Depth Clearance

Allow 131–173 mm cabinet depth for the integrated front controller module.

Cài đặt

  • Route all 3 phases + Neutral (3P+N) through the VM7LE power terminals.
  • Verify remote cost-control and communication wiring prior to energizing.
  • Press the front TEST button after installation to confirm residual-current tripping.
  • Compare with VM6LE và VM6ELY.

Câu hỏi thường gặp

What functions are integrated inside VM7LE?

VM7LE integrates electronic overcurrent protection, residual-current (earth-leakage) protection, prepaid/cost-control switching, electrical metering, and remote communication.

What current range does VM7LE cover?

From 50 A to 800 A across three 4P (3P+N) frames: VM7LE-250, VM7LE-400/630, and VM7LE-800.

What is the short-circuit breaking capacity of VM7LE?

At AC 400 V: 50/35 kA on 250 A, 50/50 kA on 400/630 A, and 65/50 kA (Icu/Ics) on 800 A.

How compact is VM7LE compared to separate assemblies?

VM7LE-250 measures just 165 × 140 × 131 mm while packing breaker, RCD, metering, and cost-control electronics in one body.

Is VM7LE suitable for utility smart-grid distribution cabinets?

Yes. It is specifically designed for smart transformer feeders, commercial sub-metering, and utility cost-control cabinets.

What is the rated insulation voltage of VM7LE?

AC 1000 V across all three frames.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Cần báo giá sản phẩm?
Hãy cùng chúng tôi thực hiện dự án này.

Gửi cho chúng tôi mã sản phẩm, các định mức kỹ thuật, số lượng và yêu cầu OEM. Đội ngũ của chúng tôi sẽ xem xét ứng dụng của bạn và phản hồi trong vòng một ngày làm việc.

Yêu cầu báo giá