MCB Bus Bar Connectors (TB25 / TB50) 25 mm² – 50 mm² Insulated Incoming Power Feed Terminals for Pin & Fork Busbars
Eliminate overcrowded breaker clamps and incoming feeder hotspots. VIOX manufactures TB25 (6–25 mm², 100A) و TB50 (10–50 mm², 160A) insulated MCB busbar connectors with pure electrolytic copper blades and UL94 V-0 PA66 housings—delivering fast, touch-safe power feed-in for 1P–4P distribution boards.
Compare VIOX TB25 (25 mm²) & TB50 (50 mm²) MCB Bus Bar Connectors
Filter by wire capacity below to inspect individual terminal geometries (straight, side-entry, angled, offset, and fork-fit) and dimensional specs.
موصل عمود التوصيل الناقل MCB TB25-1
25 mm² · Straight Pin-Type Feed-In- نطاق الكابلات
- 6 – 25 mm² Incoming Cable
- التقييم
- Up to 100 A · 500V AC
- التوافق
- Pin-Type MCB & Comb Busbar
- العزل
- Flame-Retardant PA66 UL94 V-0
موصل عمود التوصيل الناقل MCB TB25-2
25 mm² · Side-Entry Insulated Terminal- نطاق الكابلات
- 6 – 25 mm² Incoming Cable
- التقييم
- Up to 100 A · 500V AC
- التوافق
- Pin & Fork MCB Comb Busbars
- العزل
- Insulated PA66 + Tinned Copper
موصل عمود التوصيل الناقل MCB TB25-3
25 mm² · Angled Compact Feed-In- نطاق الكابلات
- 6 – 25 mm² Incoming Cable
- التقييم
- Up to 100 A · 500V AC
- التوافق
- Tight-Depth Consumer Units
- العزل
- UL94 V-0 PA66 · Touch-Safe IP20
موصل عمود التوصيل الناقل MCB TB25-4
25 mm² · Offset Pin Feed-In- نطاق الكابلات
- 6 – 25 mm² Incoming Cable
- التقييم
- Up to 100 A · 500V AC
- التوافق
- 1P / 2P / 3P / 4P MCB Banks
- العزل
- PA66 UL94 V-0 + Electrolytic Cu
موصل عمود ناقل MCB TB50-5
50 mm² Heavy-Duty · Up to 160 A- نطاق الكابلات
- 10 – 50 mm² Heavy Feeder Cable
- التقييم
- Up to 160 A · 500V AC
- التوافق
- High-Current 3P / 4P Busbars
- العزل
- Heavy-Wall PA66 + Thick Copper
موصل عمود التوصيل الناقل MCB TB25-6
25 mm² · Fork / Dual-Fit Feed-In- نطاق الكابلات
- 6 – 25 mm² Incoming Cable
- التقييم
- Up to 100 A · 500V AC
- التوافق
- Fork-Type & Standard MCBs
- العزل
- PA66 UL94 V-0 · Blue / Grey
| الطراز | Incoming Cable | الحد الأقصى للتيار | Entry Geometry | Best-Fit Panel Scenario |
|---|---|---|---|---|
| TB25-1 | 6 – 25 mm² | 100 أمبير | Straight Pin Blade | Standard top/bottom MCB comb busbar feed-in |
| TB25-2 | 6 – 25 mm² | 100 أمبير | Side-Entry Insulated | Side cable routing with limited vertical clearance |
| TB25-3 | 6 – 25 mm² | 100 أمبير | Compact Angled Pin | Shallow residential consumer units & flush boxes |
| TB25-4 | 6 – 25 mm² | 100 أمبير | Offset Pin Blade | Multi-row 3P / 4P MCB banks needing offset alignment |
| TB25-6 | 6 – 25 mm² | 100 أمبير | Fork / Dual-Fit | Fork-type comb busbars & screw-clamp MCBs |
| TB50-5 | 10 – 50 mm² | 160 A | Heavy-Duty Pin Blade | Main commercial switchboard feeders & center-feed banks |
Match the Exact TB25 / TB50 Connector to Your MCB & Cable
Select incoming feeder cable size, comb busbar profile, and panel wiring clearance to pick the right VIOX busbar connector and feed-in position.
How to Install VIOX TB25 / TB50 Busbar Connectors Safely on MCB Banks
Review the factory mounting sequence below—and see why dedicated insulated feed-in connectors prevent loose clamps and thermal burnout.
Stops Double-Clamp Hotspots
Prevents jamming a 25–50 mm² feeder cable beside a comb busbar pin inside one MCB cage—eliminating uneven torque and terminal charring.
Doubles Busbar Capacity via Center-Feed
Mounting a TB25 or TB50 connector in the middle of a 3P/4P comb busbar splits load current evenly left and right, reducing I²R heating.
Complete IP20 Touch-Safe Housing
Self-extinguishing UL94 V-0 PA66 shroud shields all live copper conductors against accidental screwdriver or finger contact during O&M.
Generate Your MCB Busbar Connector RFQ in 30 Seconds
Choose your TB25/TB50 model, color coding, comb busbar bundle, and packaging—then copy or send directly to VIOX sales.
MCB Busbar Connector & Comb Busbar Technical Guides
Practical engineering guides on Pin vs. Fork compatibility, avoiding overheating, and safe busbar feed-in wiring.
Pin Type Busbar vs. Fork Type Busbar: Compatibility Guide
Match Pin and Fork comb busbar profiles with the right TB25/TB50 feed-in connector and MCB terminal.
Explore Guide →5 أخطاء في تركيب قضبان التوزيع (Busbar) الخاصة بـ MCB—وكيفية تجنبها
Avoid double-wire stuffing, missed torque checks, and exposed end cuts inside distribution boards.
Explore Guide →دليل اختيار قضبان التوزيع (Busbar) لقواطع الدائرة MCB: نوع Pin، نوع Fork، أحادي/ثلاثي الأقطاب (1P/3P) والتصنيفات
How to size busbar cross-section, center-feed vs. end-feed ampacity, and incoming feed terminals.
Explore Guide →Why Is Your MCB Busbar Overheating? Causes & Fixes
Eliminate incoming feeder hotspots by upgrading to dedicated TB25/TB50 insulated feed-in connectors.
Explore Guide →VIOX Pin & Fork Comb Busbars (1P / 2P / 3P / 4P)
Browse all 21 VIOX Pin-type and Fork-type insulated copper comb busbars for DIN rail MCBs.
Explore Guide →VIOX Miniature Circuit Breakers (MCB · 6A–125A)
Pair TB25/TB50 busbar connectors with VIOX IEC 60898-1 / 60947-2 DIN rail MCBs.
Explore Guide →MCB Bus Bar Connector Selection & Installation Questions
Why Needed Why should I use an MCB busbar feed-in connector (TB25/TB50) instead of stuffing a thick wire into the breaker terminal?
Forcing a 25 mm² or 50 mm² incoming feeder cable into the same MCB cage clamp that already holds a comb busbar pin causes uneven clamping pressure, splayed strands, and dangerous terminal hotspots. A VIOX TB25 or TB50 feed-in connector clamps onto the MCB/busbar independently with a dedicated heavy screw tunnel—delivering full IP20 touch-safe insulation and uniform torque.
TB25 vs. TB50 What is the difference between TB25 (25 mm²) and TB50 (50 mm²) busbar connectors?
The TB25 series (TB25-1, TB25-2, TB25-3, TB25-4, TB25-6) accepts incoming cables from 6 to 25 mm² (rated up to 100 A), making it ideal for standard residential and light commercial distribution boards. The TB50-5 accepts heavy feeder cables up to 50 mm² (rated up to 160 A) for main commercial switchboards and high-load 3-phase MCB banks.
Center vs. End Feed Should I mount the busbar feed-in connector at the end or the center of the MCB comb busbar?
For total loads below the comb busbar single-end rating (typically ≤ 63A–80A), end-feeding is standard. For higher total busbar currents (80A–130A+), center-feeding with a TB25 or TB50 connector splits the current equally to the left and right halves of the comb busbar—effectively doubling safe current capacity and cutting busbar temperature rise.
التوافق Are VIOX TB25 and TB50 busbar connectors compatible with Pin-type and Fork-type MCBs?
Yes. VIOX offers dedicated pin-blade models (TB25-1, TB25-3, TB25-4, TB50-5) and fork/dual-fit geometries (TB25-2, TB25-6) that fit standard IEC 60898-1 18 mm modular MCBs, RCBOs, and RCCBs alongside VIOX Pin and Fork comb busbars.
Safety & Insulation Are VIOX MCB busbar connectors finger-safe (IP20) and flame-retardant?
Yes. Every TB25 and TB50 connector is molded from self-extinguishing UL94 V-0 PA66 polyamide that encloses the live copper blade and clamping screw to IP20 finger-safe protection, eliminating exposed live metal inside distribution boards.
الإكسسوارات Can I order TB25/TB50 feed-in connectors bundled with VIOX Pin/Fork comb busbars and end caps?
Yes. Most panel builders and distributors consolidate TB25/TB50 feed-in terminals, 1P/2P/3P/4P comb busbars (1-meter bars or cut lengths), insulated end caps, and tooth covers on a single factory shipment.
Need TB25 / TB50 Busbar Connectors & Matched Comb Busbars?
Consolidate MCB busbar feed-in connectors, 1P–4P Pin/Fork comb busbars, end caps, and DIN rail MCBs on one factory PO with 24-hour engineering quotation.