VIOX ELECTRIC
اللغة
Direct Factory · IP68 ePTFE Pressure Equalization Valve Manufacturer

Breather Vent Plugs (Metal & Nylon) IP68 ePTFE Enclosure Pressure Equalization & Anti-Condensation Valves

Protect outdoor electrical cabinets, LED luminaires, EV chargers, and solar inverters from vacuum moisture ingress. VIOX manufactures screw-in 304/316L Stainless Steel, Nickel-Plated Brass, Anodized Aluminum, Black Metal, and PA66 Nylon breather vent plugs delivering up to 2,200 ml/min @ 70 mbar airflow across M6–M40, PG, G, and NPT threads.

2,200 ml/minHigh Airflow @ 70 mbar
IP67 / IP68>10 kPa – 5 bar Water Entry
-40°C to +250°CPA66, Alu, Brass & 316L
VIOX Full Range of Metal, Aluminum, Stainless Steel and PA66 Nylon Breather Vent Plugs
01 · Complete Breather Vent Plug Lineup (10 Real Factory Models)

Compare VIOX Stainless Steel, Brass, Aluminum & PA66 Breather Vent Plugs

Filter our full screw-in breather vent plug catalog by housing material, then compare operating temperature, airflow rate, and salt-spray ratings in the engineering matrix.

Engineering material comparison: VIOX IP68 ePTFE Breather Vent Plugs across 6 housing options
مواد الإسكان نطاق درجة الحرارة Airflow (@ 70 mbar) Water Entry / IP Salt Spray (IEC 68-2-11) Best-Fit Applications
304 / 316L Stainless Steel-40 درجة مئوية إلى +125 درجة مئوية2,200 ml/minIP65–IP68 (>10 kPa)96h+ Marine GradeOffshore wind, marine cabinets, food & chemical washdown
High-Temp Nickel Brass-40°C to +250°C0.2 ml – 12 L/h @ 7 kPaIP67–IP68 (5 بار)Nickel corrosion shieldHigh-wattage LED floodlights, motor housings, hot machinery
نحاس مطلي بالنيكل-40 درجة مئوية إلى +125 درجة مئوية2,200 ml/minIP65–IP68 (>10 kPa)96 hoursEV chargers, steel control cabinets, railway & outdoor switchgear
Anodized Aluminum Alloy-40 درجة مئوية إلى +125 درجة مئوية2,200 ml/minIP65–IP68 (>10 kPa)96 hoursDie-cast LED street lights, 5G telecom radios, solar inverters
Black Coated Metal-40 درجة مئوية إلى +125 درجة مئوية2,200 ml/minIP65–IP68 (>10 kPa)96 hoursArchitectural black luminaires, EV pedestals, outdoor CCTV
PA66 UV Nylon-40 درجة مئوية إلى +100 درجة مئويةUp to 1,500 ml/minIP67–IP68 (2m / 60 min)Zero rust / non-metallicPolycarbonate junction boxes, PV combiner boxes, IoT sensors
02 · Interactive Airflow, Quantity & Material Sizer

Match Breather Vent Plug Count, Material & Thread to Your Enclosure

Set your sealed cabinet internal volume, environmental exposure, and thread standard to size the right VIOX breather vent plug configuration.

20 L
2. Operating Environment & Housing Duty
3. Panel Knockout Thread Standard
03 · Section A-A CAD Cutaway & Thermal-Cycle Simulator

How a Screw-In ePTFE Breather Vent Plug Stops Enclosure Condensation

Based directly on VIOX factory Section A-A engineering drawings: inspect the internal waterproof breathable ePTFE membrane seated behind the slotted hex head, then toggle field conditions below.

SECTION A-A CADScrew-In Breather Vent Plug — Internal Cutaway Schematic
Slotted Hex Cap + Flat ePTFE Membrane + Threaded Through-Bore
OUTSIDE (RAIN · WASHDOWN · DUST) INSIDE ENCLOSURE (DRY PCB · ΔP ≈ 0) Cabinet Wall Rain, Washdown & Oil Mist Blocked Outside (IP68) Balanced Pressure ΔP ≈ 0 mbar Air & Vapor Equalize (⇄) Zero PCB Condensation Side Vent Slots ePTFE Waterproof Membrane صامولة القفل Central Through-Bore M6–M40 / PG / NPT Silicone / EPDM O-Ring
LAB 01Enclosure Pressure & Condensation Simulator (ΔT = 40°C Rain Quench)

Unvented Sealed Enclosure (No Plug)

CONDENSATION RISK

    VIOX ePTFE Breather Vent Plug

    DRY · IP68 PROTECTED

      Up to 2,200 ml/min High Airflow

      Rapidly equalizes large enclosures (25 L–150 L+) during sudden rain storms or rapid LED/inverter cool-down—where small cable-gland vents alone cannot keep up.

      Hydrophobic & Oleophobic ePTFE

      Sub-micron membrane pores pass air and water vapor continuously while repelling liquid rain, high-pressure washdown spray, oil mist, and coastal salt fog.

      Extends Enclosure Gasket Life

      Eliminating daily ±120 mbar pressure cycles stops cabinet door seals from ballooning and fatiguing—preventing premature IP68 field failures.

      04 · Direct Factory Proof · 100% Membrane & Salt-Spray QC

      Quotation Variables, ePTFE Membrane Testing & OEM Supply

      In-house CNC turning (316L stainless, brass, aluminum), PA66 injection molding, and ultrasonic ePTFE membrane welding with full batch traceability.

      1. Airflow & WEP Verification

      Every production lot is audited for 2,200 ml/min @ 70 mbar airflow consistency and IP68 water-entry pressure (>10 kPa to 5 bar).

      2. 96h Salt Spray (IEC 68-2-11)

      Metal, anodized aluminum, and 304/316L stainless steel housings undergo salt-fog corrosion verification for coastal and marine deployment.

      3. Custom Threads & O-Rings

      Standard Metric (M6–M40), PG, G (PF), and NPT threads stocked with EPDM, Viton, or +250°C high-temperature silicone O-rings.

      05 · Interactive B2B Tool · 5-Step Breather Vent Plug RFQ Builder

      Generate Your Breather Vent Plug RFQ in 30 Seconds

      Select housing material, thread size, ePTFE membrane grade, and order quantity, then copy or attach directly to the VIOX sales form.

      1. Housing Material
      2. Thread Standard & Size
      3. ePTFE Membrane & O-Ring Grade
      4. Order / Sample Volume
      5. Supply & Branding
      06 · Enclosure Venting & Condensation Knowledge Hub

      Breather Vent Plug & Condensation Prevention Guides

      Engineering articles authored by VIOX enclosure protection specialists covering ePTFE physics, airflow sizing, and breather plug selection.

      07 · Technical & Sourcing FAQ

      Breather Vent Plug Selection & Installation Questions

      مبدأ العمل How does an IP68 breather vent plug equalize pressure while blocking rain and dust?

      A VIOX breather vent plug seats a hydrophobic and oleophobic expanded PTFE (ePTFE) microporous membrane flat across the internal airway bore behind a slotted protective hex head. Its sub-micron pores allow air and water vapor molecules to flow freely (up to 2,200 ml/min @ 70 mbar) to equalize pressure, while blocking liquid water droplets, dust, and salt mist at IP67/IP68 ratings.

      Airflow Sizing How do I size breather vent plug quantity and thread for my enclosure volume?

      Compact housings under 5 L (LED luminaires, sensors, IoT boxes) typically use one M6×1 or M12×1.5 vent plug. Medium boxes from 5–25 L (PV combiners, EV chargers) perform best with one high-flow M12/M16 vent rated at 2,200 ml/min @ 70 mbar. Cabinets over 25–100 L should install two vents (low inlet + upper exhaust) for rapid thermal-cycle equalization.

      Vent vs. Gland When should I use a breather vent plug instead of a breathable cable gland?

      Specify a standalone breather vent plug when enclosure volume exceeds 25 L, when maximum airflow (2,200 ml/min @ 70 mbar) is needed, or when retrofitting an already-wired cabinet. Choose a VIOX breathable cable gland on compact boxes under 15–20 L when saving a second knockout hole is the priority.

      المواد How do I choose between PA66 nylon, aluminum alloy, nickel-plated brass, and 316L stainless steel?

      Use PA66 nylon for polycarbonate boxes, UV outdoor LEDs, and cost-sensitive solar housings (-40°C to +100°C). Use anodized aluminum for lightweight die-cast luminaires and 5G telecom enclosures. Specify nickel-plated brass for rugged steel cabinets (or up to +250°C with our high-temp silicone series), and 304/316L stainless steel for coastal salt-spray, offshore, and chemical washdown environments.

      التركيب Where should a breather vent plug be mounted on an outdoor electrical cabinet?

      Mount the breather vent plug on a sheltered vertical sidewall—never face-up on a flat roof where standing water, mud, or ice can pool over the vent slots. Compress the silicone or EPDM O-ring evenly against a clean, burr-free panel surface using the supplied locknut.

      Membrane Grade What is the difference between hydrophobic and oleophobic ePTFE membranes?

      Hydrophobic ePTFE repels liquid water and rain. Oleophobic ePTFE adds a low-surface-energy treatment that also repels low-surface-tension fluids such as hydraulic oil mist, cutting fluids, cleaning detergents, and automotive fuels—preventing membrane pore wetting in factory automation, EV chargers, and marine environments.

      Direct Engineering & OEM Support

      Need Breather Vent Plug CAD Drawings or Sample Kits?

      Share your enclosure volume, operating temperature, thread size, and salt-spray or oil exposure. VIOX engineers will reply with 2D/3D CAD files, airflow curves, and factory pricing within 24 hours.

      10 Metal, Alu & PA66 Models Stocked 2,200 ml/min @ 70 mbar Airflow M6–M40 · PG · G · NPT Threads