VIOX ELECTRIC
اللغة

VIOX 690VAC 630A NH3 HRC Fuse

NH3 China fuse expert VIOX 690VAC 630A NH3 HRC Fuse is valid for general use protection to both overload and short circuit protection indicated as motors, transformers and other loads with high inrush current with different operating class such as gG/gL, aM and aR. This square body.

سلسلة VIOX
NH3
الجهد المقنن
690VAC
التيار المقنن
630أ
قياسي
IEC 60269

نظرة عامة

NH3 China fuse expert VIOX 690VAC 630A NH3 HRC Fuse is valid for general use protection to both overload and short circuit protection indicated as motors, transformers and other loads with high inrush current with different operating class such as gG/gL, aM and aR. This square body with blade terminals fuse was made in a standardized configuration for global acceptance. 690VAC 630A NH3 HRC Fuse is available in multiple ampere ratings from 315A up to 630A, which helps match specific requirements in various industrial applications, such as motors, transformers, low voltage distribution, control circuits and so on.

الميزات

  • Rated voltage 690VAC and current capacity 630A for low-voltage hrc industrial fuse applications.
  • High interrupting performance (High Breaking Capacity) with rapid current-limiting fault clearing.
  • Engineered and tested in accordance with IEC 60269 standards.
  • Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
  • Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.

المواصفات

NH3 Technical Specifications

Model/Size الجهد المقنن (فولت) التيار المقدر (أمبير) البُعد الكلي
A D E H H1 H2
NH3 500/690 315, 355, 400, 425, 500, 630 150 74 67 82 32 71

NH3 Ratings & Dimensions Table 2

Model/Size الجهد المقنن (فولت) التيار المقدر (أمبير) البُعد الكلي
A B F H
YR:Sist601 690 630 239 210 40 106

Selection & Installation Notes

  • Verify system maximum voltage (690VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

الأسئلة الشائعة

What voltage and current ratings does the VIOX 690VAC 630A NH3 HRC Fuse support?

This VIOX NH3 series is rated for 690VAC with a current rating of 630A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX 690VAC 630A NH3 HRC Fuse?

The NH3 series is designed and verified to IEC 60269 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX 690VAC 630A NH3 HRC Fuse typically installed?

It is engineered for low-voltage hrc industrial fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.

هل تحتاج إلى عرض سعر للمنتج؟
لنبنيها معاً.

أرسل لنا طراز المنتج، والتقييمات الفنية، والكمية، ومتطلبات الشركة المصنعة للمعدات الأصلية (OEM). سيقوم فريقنا بمراجعة طلبك والرد في غضون يوم عمل واحد.

طلب عرض أسعار