Power Distribution Blocks (UKK 80A–500A, K-Series & Modular) IP20 Finger-Safe AC & DC Electrical Power Blocks · 1-In 6-Out & 1-In 11-Out DIN-Rail / Panel Mount
VIOX Electric manufactures heavy-duty كتل توزيع الطاقة engineered to split a single high-current feeder (up to 240 mm² / 500 kcmil) cleanly into 6 to 11 branch circuits inside switchgear cabinets, OEM control panels, and 1000V DC solar combiner boxes—spanning UKK 80A, 125A, 160A, 250A, 400A, and 500A (Blue, Red, Green, Yellow), plus K-Series و UTJ5 modular distribution blocks.
What Is a Power Distribution Block? (AC & DC Electrical Power Blocks)
A كتلة توزيع الطاقة (يُسمى أيضًا electrical power block or UKK junction terminal block) is an insulated, high-current splicing and branching assembly that splits one large incoming primary feeder cable into multiple smaller secondary branch circuits. Built around a solid tin-plated brass or electrolytic copper conductor bar inside an IP20 flame-retardant PA66 housing, it safely distributes both 690 فولت تيار متردد industrial power and 1000 فولت تيار مستمر solar or battery power without loose multi-wire lugs.
In industrial switchgear, HVAC motor control centers (MCCs), and renewable-energy combiner cabinets, terminating three or more conductors under a single breaker lug violates electrical codes and creates high-resistance thermal hot spots. A dedicated AC/DC power distribution block replaces improvised jumper bridges with individually torqued hex-socket screw ports, a hinged transparent polycarbonate inspection cover, and snap-on 35 mm DIN-rail or backplate screw mounting—cutting panel wiring labor by up to 50% while maintaining clean, traceable branch circuits.
Solid Tin-Plated Brass Conductor Core
Low-resistance solid brass bus blocks prevent oxidation and galvanic heating under continuous 80A–500A industrial loads, maintaining stable millivolt drop across all 6 or 11 branch taps.
IP20 Finger-Safe Hinged PC Cover
Every VIOX UKK electrical power block includes a transparent, hinged polycarbonate lid that protects technicians from accidental live-bus contact while allowing instant visual wire inspection.
Interlocking Multi-Pole Color System
Side dovetail slots snap single-pole blocks into rigid 2P, 3P, or 3P+N assemblies using color-coded Blue (Neutral), Red/Yellow (Phases), and Green (PE Earth) PA66 UL94 V-0 housings.
UKK Series Power Distribution Blocks (80A–500A · 1-in-6 & 1-in-11 Out)
Explore all 6 current frames of the VIOX UKK power distribution block lineup below. Each current rating is stocked in Blue, Red, Green, and Yellow housings for rapid multi-phase switchgear assembly.
VIOX UKK 80A 1-In 6-Out Distribution Block
UKK-80A · 1-In 6-Out- Main Input
- 1 × 16 mm² (6 AWG)
- Branch Outputs
- 4×6 mm² + 2×16 mm²
- الجهد المقنن
- 690V AC / 1000V DC
- Stock Colors
- Blue · Red · Green · Yellow
VIOX UKK 125A 1-In 6-Out Distribution Block
UKK-125A · 1-In 6-Out- Main Input
- 1 × 35 mm² (2 AWG)
- Branch Outputs
- 6 × 16 mm² (6 AWG)
- الجهد المقنن
- 690V AC / 1000V DC
- Stock Colors
- Blue · Red · Green · Yellow
VIOX UKK 160A 1-In 6-Out Distribution Block
UKK-160A · 1-In 6-Out- Main Input
- 1 × 70 mm² (2/0 AWG)
- Branch Outputs
- 6 × 16 mm² (6 AWG)
- الجهد المقنن
- 690V AC / 1000V DC
- Stock Colors
- Blue · Red · Green · Yellow
VIOX UKK 250A 1-In 11-Out Distribution Block
UKK-250A · 1-In 11-Out- Main Input
- 1 × 120 mm² (4/0 AWG)
- Branch Outputs
- 2×35 + 5×16 + 4×10 mm²
- الجهد المقنن
- 690V AC / 1000V DC
- Stock Colors
- Blue · Red · Green · Yellow
VIOX UKK 400A 1-In 11-Out Distribution Block
UKK-400A · 1-In 11-Out- Main Input
- 1 × 185 mm² (350 kcmil)
- Branch Outputs
- 2×35 + 5×16 + 4×10 mm²
- الجهد المقنن
- 690V AC / 1000V DC
- Stock Colors
- Blue · Red · Green · Yellow
VIOX UKK 500A 1-In 11-Out Distribution Block
UKK-500A · 1-In 11-Out- Main Input
- 1 × 240 mm² (500 kcmil)
- Branch Outputs
- 2×35 + 5×16 + 4×10 mm²
- الجهد المقنن
- 690V AC / 1000V DC
- Stock Colors
- Blue · Red · Green · Yellow
| Model / Rating | Main Input (mm² / AWG) | Output Ports & Wire Range | جهد العزل (Ui) | Mounting & IP | Product Datasheet |
|---|---|---|---|---|---|
| UKK-80A | 1 × 16 mm² (6 AWG) | 1-in-6 out: 4 × 6 mm² + 2 × 16 mm² | 690V AC / 1000V DC | 35mm DIN-Rail / Screw · IP20 | UKK-80A Blue → |
| UKK-125A | 1 × 35 mm² (2 AWG) | 1-in-6 out: 6 × 16 mm² (6 AWG) | 690V AC / 1000V DC | 35mm DIN-Rail / Screw · IP20 | UKK-125A Blue → |
| UKK-160A | 1 × 70 mm² (2/0 AWG) | 1-in-6 out: 6 × 16 mm² (6 AWG) | 690V AC / 1000V DC | 35mm DIN-Rail / Screw · IP20 | UKK-160A Blue → |
| UKK-250A | 1 × 120 mm² (4/0 AWG) | 1-in-11 out: 2×35 + 5×16 + 4×10 mm² | 690V AC / 1000V DC | 35mm DIN-Rail / Screw · IP20 | UKK-250A Blue → |
| UKK-400A | 1 × 185 mm² (350 kcmil) | 1-in-11 out: 2×35 + 5×16 + 4×10 mm² | 690V AC / 1000V DC | 35mm DIN-Rail / Screw · IP20 | UKK-400A Blue → |
| UKK-500A | 1 × 240 mm² (500 kcmil) | 1-in-11 out: 2×35 + 5×16 + 4×10 mm² | 690V AC / 1000V DC | 35mm DIN-Rail / Screw · IP20 | UKK-500A Blue → |
K-Series & Modular Power Distribution Blocks
Alongside our flagship single-pole UKK 80A–500A blocks, VIOX manufactures complete multi-pole K-Series neutral/phase distribution blocks and high-current UTJ5 rail-type junction blocks for space-constrained sub-distribution enclosures.
UKK Power Distribution Block Family (80A–500A)
UKK Series · Complete Range- التكوين
- 80A · 125A · 160A · 250A · 400A · 500A
- التركيب
- 35 mm DIN Rail or Screw Mount
- الحماية
- IP20 Hinged Clear PC Cover
- الأنسب لـ
- IEC 60947-7-1 · UL 1059
K-Series DIN Rail Neutral & Power Distribution Block
K-Series · Multi-Pole Modular- التكوين
- 2P / 4P Multi-Bar Configurations
- التركيب
- 35 mm DIN Rail Snap-On
- الحماية
- Color-Coded Phase & Neutral Bars
- الأنسب لـ
- Compact Sub-Panels & Control Cabinets
UTJ5 High-Current DIN Rail Distribution Block
UTJ5 Series · High-Current Rail- التكوين
- High-Current Multi-Branch Tap
- التركيب
- 35 mm DIN Rail & Panel Base
- الحماية
- Heavy-Duty Tin-Plated Brass Core
- الأنسب لـ
- Switchgear Feeders & Industrial MCCs
When panel builders assemble compact 2-pole or 4-pole lighting and commercial distribution boards where horizontal DIN-rail space is tighter than vertical depth, the K-Series modular distribution block stacks 2 or 4 stepped brass bars inside a single insulated enclosure with color-coded phase barriers. For industrial feeder branches that require high mechanical pull-out retention directly on TS35 rail, the UTJ5 rail-type junction block series delivers oversized screw clamping and clear terminal numbering for rapid maintenance sign-off.
How to Select a Power Distribution Block from Your Conductor Schedule
Follow these five engineering checks to size an AC or DC electrical power block accurately from your panel’s single-line diagram and cable schedule.
1. Main Current & 125% Derating
Size the block’s rated current at least 1.25× above continuous feeder current (e.g., use UKK-160A for a 120A continuous feeder) to keep brass temperature rise well below IEC 60947-7-1 limits inside sealed enclosures.
2. Input / Output mm² & AWG
Match both the largest incoming cable cross-section (16 to 240 mm²) and every outgoing branch wire size. Always crimp ferrules on fine-stranded flexible conductors before torquing hex screws.
3. Pole Count & Color Coding
Snap single-pole UKK units into 2P (DC +/-), 3P (L1/L2/L3), or 3P+N+PE banks using Blue, Red, Yellow, and Green housings—or select a compact 4P K-Series multi-bar modular block.
4. AC/DC Voltage & Standards
تحقق Ui = 690V AC / 1000V DC insulation clearance for solar PV and BESS cabinets, and confirm IEC 60947-7-1, UL 1059, or feeder-side UL 1953 compliance with your local inspector.
كتلة توزيع الطاقة مقابل كتلة الأطراف مقابل قضيب التوصيل
Compare UKK single-pole blocks, modular multi-pole blocks, standard كتل طرفية DIN السكك الحديدية DINو قضبان التوصيل المشطية النحاسية to pick the lowest-cost, cleanest panel architecture.
| Engineering Criterion | UKK Power Distribution Block (80A–500A) | K-Series / UTJ5 Modular Block | Standard DIN Terminal Block (UK / ST / PT) | Insulated Copper Busbar |
|---|---|---|---|---|
| التصنيف الحالي النموذجي | 80A to 500A per pole | 63A to 250A multi-bar / rail | 24A to 125A (1-to-1 feed-through) | 63A to 125A (MCB comb) · 400A+ bar |
| Branching Density | 1-in-6 or 1-in-11 out in one body | 2P / 4P grouped phase + neutral taps | Requires external jumper combs | Fixed 18 mm pitch for MCB rows |
| Incoming Cable Size | 16 mm² up to 240 mm² (6 AWG–500 kcmil) | 10 mm² to 70 mm² | 0.5 mm² to 35 mm² | Feed-in terminal or crimped cable lug |
| IP20 Finger-Safe Cover | Built-in hinged transparent PC lid | Snap-on transparent barrier cover | Touch-safe recessed screw channels | Exposed without end caps / shrouds |
| Best Panel Role | Main feeder splitting in switchgear, MCCs & 1000V DC solar boxes | Compact sub-panels & neutral/phase grouped distribution | Control I/O, PLC marshalling & individual load terminations | Linking adjacent 1P–4P MCBs & RCBOs on one DIN rail |
| VIOX Hub Link | Explore UKK 80A–500A ↑ | Explore K-Series & UTJ5 ↑ | DIN Terminal Blocks → | قضبان توصيل مشطية لـ MCB → |
Complete Your Feeder Termination Hardware
When wiring 35–240 mm² incoming cables into UKK-125A through UKK-500A blocks or main MCCB lugs, pair your distribution blocks with VIOX DT/DTL copper & bimetallic cable lugs, route downstream breaker rows with insulated MCB comb busbars, and organize control-circuit branches with UK/ST/PT DIN rail terminal blocks on one consolidated OEM factory shipment.
Industrial, Switchgear & Solar DC Applications
Where electrical engineers, panel builders, and EPC contractors deploy VIOX UKK and modular power distribution blocks worldwide.
Switchgear & Main Incoming Feeders
Split a 185–240 mm² incoming MCCB feeder via UKK-400A / UKK-500A (1-in-11-out) cleanly across motor starter rows, VFD drives, and auxiliary transformer branches without custom copper bar fabrication.
1000V DC Solar PV & BESS Combiners
Combine parallel DC string fuses or split battery rack feeders using 1000V DC rated UKK power distribution blocks in Red (+) and Blue/Black (−) housings inside outdoor IP65 combiner boxes.
OEM Control Panels & HVAC Chiller Skids
Use compact UKK-80A / 125A / 160A و K-Series blocks on 35 mm DIN rail to feed compressors, condenser fans, and control transformers with full IP20 maintenance safety.
What Is a Power Distribution Block? Complete Engineering Guide
How electrical power blocks split main feeders, compare UL 1953 vs. UL 1059, and save switchgear space.
Explore Guide →How to Select the Right UKK Terminal Block (80A–500A)
Step-by-step sizing of UKK input/output wire gauges, current derating, and multi-pole color coding.
Explore Guide →Busbars vs. Terminal Blocks: Choosing Power Distribution Hardware
When to deploy copper comb busbars, modular terminal blocks, or enclosed UKK distribution blocks.
Explore Guide →DIN Rail & Barrier Terminal Blocks (UK / ST / PT Series)
Modular screw, spring-cage, and push-in terminal blocks for control circuits and branch terminations.
Explore Guide →MCB Comb Busbars & Copper Distribution Bars (1P–4P)
Pin and fork insulated copper busbars for high-density MCB and RCBO feeder rows.
Explore Guide →Copper & Bimetallic Cable Lugs (DT / DTL / SC Series)
Heavy-duty crimp lugs and bootlace ferrules for secure 16–240 mm² UKK feeder terminations.
Explore Guide →Power Distribution Block & UKK Selection FAQ
DC & Solar Can UKK power distribution blocks be used for DC solar and battery systems?
Yes. VIOX UKK 80A–500A power distribution blocks are rated up to 1000V DC (690V AC) under IEC 60947-7-1 with PA66 UL94 V-0 flame-retardant housings and high creepage clearance. They are widely used inside 1000V DC solar PV combiner boxes, battery energy storage (BESS) cabinets, and DC EV charging distribution rails when sized with a 125% continuous-duty current margin.
UKK Sizing How do I choose between UKK 80A, 125A, 160A, 250A, 400A, and 500A?
Start with both your main feeder current (applying a 1.25× continuous-load factor) and your incoming cable cross-section. UKK-80A accepts up to 16 mm², UKK-125A accepts 35 mm², and UKK-160A accepts 70 mm² in a 1-in-6-out layout. When you need 7 to 11 outgoing branch circuits or heavy feeders up to 120 mm² (UKK-250A), 185 mm² (UKK-400A), or 240 mm² (UKK-500A), step up to the 1-in-11-out series.
DIN vs. Screw Do VIOX UKK power distribution blocks mount on 35mm DIN rail or panel backplates?
Every VIOX UKK power distribution block (80A through 500A) supports dual mounting: snap directly onto standard 35 mm TS35 DIN rail for fast cabinet assembly, or bolt directly to a steel backplate using the integrated M5/M6 mounting holes for high-vibration or heavy 120–240 mm² cable terminations.
Multi-Pole How do I build a 3-phase + neutral electrical power block assembly using UKK blocks?
Single-pole UKK blocks feature dovetail interlocking slots on the housing sides so you can snap 3 or 4 units together into a rigid 3P or 3P+N distribution assembly. VIOX stocks Blue (Neutral), Red/Yellow (Phases L1/L2/L3), and Green (PE Earth) housings across 80A–500A for instant visual circuit identification.
Copper & Aluminum Can UKK power distribution blocks terminate both fine-stranded flexible wire and rigid cables?
Yes. VIOX UKK brass conductor blocks accommodate solid, stranded, and fine-stranded copper conductors. For fine-stranded flexible cables (Class 5/6), always crimp insulated or uninsulated copper bootlace ferrules before tightening the hex socket screw to the specified torque to prevent strand splaying and hot spots.
المعايير What is the difference between IEC 60947-7-1, UL 1059, and UL 1953 for power distribution blocks?
IEC 60947-7-1 governs low-voltage terminal and distribution blocks globally, specifying temperature rise, short-time withstand current, and dielectric strength up to 1000V. In North America, UL 1059 covers industrial control-panel terminal blocks (typically on the load side of branch protection), while UL 1953 specifies feeder-circuit power distribution blocks with higher spacing and SCCR requirements.
Need UKK 80A–500A, K-Series or UTJ5 Blocks for Your Next Panel BOM?
Send your amp ratings, color quantities (Blue / Red / Green / Yellow), and OEM branding needs. VIOX factory engineering replies with CAD drawings and wholesale pricing within 24 hours.