VIOX ELECTRIC
اللغة
Direct Factory · IEC 60947-7-1 & UL 1059 Power Distribution Block Manufacturer

Power Distribution Blocks (UKK 80A–500A, K-Series & Modular) IP20 Finger-Safe AC & DC Electrical Power Blocks · 1-In 6-Out & 1-In 11-Out DIN-Rail / Panel Mount

VIOX Electric manufactures heavy-duty كتل توزيع الطاقة engineered to split a single high-current feeder (up to 240 mm² / 500 kcmil) cleanly into 6 to 11 branch circuits inside switchgear cabinets, OEM control panels, and 1000V DC solar combiner boxes—spanning UKK 80A, 125A, 160A, 250A, 400A, and 500A (Blue, Red, Green, Yellow), plus K-Series و UTJ5 modular distribution blocks.

80A – 500A6 UKK Frames · 25+ Stock SKUs
690V AC / 1000V DCIEC 60947-7-1 · PA66 UL94 V-0
1-In 6 / 11 Out35mm DIN Rail & Screw Mount
VIOX UKK 80A to 500A Power Distribution Blocks for DIN-Rail and Panel Mounting
01 · Fundamentals · AC & DC Electrical Power Blocks

What Is a Power Distribution Block? (AC & DC Electrical Power Blocks)

A كتلة توزيع الطاقة (يُسمى أيضًا electrical power block or UKK junction terminal block) is an insulated, high-current splicing and branching assembly that splits one large incoming primary feeder cable into multiple smaller secondary branch circuits. Built around a solid tin-plated brass or electrolytic copper conductor bar inside an IP20 flame-retardant PA66 housing, it safely distributes both 690 فولت تيار متردد industrial power and 1000 فولت تيار مستمر solar or battery power without loose multi-wire lugs.

In industrial switchgear, HVAC motor control centers (MCCs), and renewable-energy combiner cabinets, terminating three or more conductors under a single breaker lug violates electrical codes and creates high-resistance thermal hot spots. A dedicated AC/DC power distribution block replaces improvised jumper bridges with individually torqued hex-socket screw ports, a hinged transparent polycarbonate inspection cover, and snap-on 35 mm DIN-rail or backplate screw mounting—cutting panel wiring labor by up to 50% while maintaining clean, traceable branch circuits.

Solid Tin-Plated Brass Conductor Core

Low-resistance solid brass bus blocks prevent oxidation and galvanic heating under continuous 80A–500A industrial loads, maintaining stable millivolt drop across all 6 or 11 branch taps.

IP20 Finger-Safe Hinged PC Cover

Every VIOX UKK electrical power block includes a transparent, hinged polycarbonate lid that protects technicians from accidental live-bus contact while allowing instant visual wire inspection.

Interlocking Multi-Pole Color System

Side dovetail slots snap single-pole blocks into rigid 2P, 3P, or 3P+N assemblies using color-coded Blue (Neutral), Red/Yellow (Phases), and Green (PE Earth) PA66 UL94 V-0 housings.

02 · Complete UKK Catalog (80A–500A · 25 Stocked SKUs)

UKK Series Power Distribution Blocks (80A–500A · 1-in-6 & 1-in-11 Out)

Explore all 6 current frames of the VIOX UKK power distribution block lineup below. Each current rating is stocked in Blue, Red, Green, and Yellow housings for rapid multi-phase switchgear assembly.

UKK Series Full Selection Matrix (80A / 125A / 160A / 250A / 400A / 500A) — IEC 60947-7-1
Model / Rating Main Input (mm² / AWG) Output Ports & Wire Range جهد العزل (Ui) Mounting & IP Product Datasheet
UKK-80A 1 × 16 mm² (6 AWG) 1-in-6 out: 4 × 6 mm² + 2 × 16 mm² 690V AC / 1000V DC 35mm DIN-Rail / Screw · IP20 UKK-80A Blue →
UKK-125A 1 × 35 mm² (2 AWG) 1-in-6 out: 6 × 16 mm² (6 AWG) 690V AC / 1000V DC 35mm DIN-Rail / Screw · IP20 UKK-125A Blue →
UKK-160A 1 × 70 mm² (2/0 AWG) 1-in-6 out: 6 × 16 mm² (6 AWG) 690V AC / 1000V DC 35mm DIN-Rail / Screw · IP20 UKK-160A Blue →
UKK-250A 1 × 120 mm² (4/0 AWG) 1-in-11 out: 2×35 + 5×16 + 4×10 mm² 690V AC / 1000V DC 35mm DIN-Rail / Screw · IP20 UKK-250A Blue →
UKK-400A 1 × 185 mm² (350 kcmil) 1-in-11 out: 2×35 + 5×16 + 4×10 mm² 690V AC / 1000V DC 35mm DIN-Rail / Screw · IP20 UKK-400A Blue →
UKK-500A 1 × 240 mm² (500 kcmil) 1-in-11 out: 2×35 + 5×16 + 4×10 mm² 690V AC / 1000V DC 35mm DIN-Rail / Screw · IP20 UKK-500A Blue →
1. Main Feeder Current (with 125% Continuous Margin)
2. Outgoing Branch Circuits Needed per Pole
3. Electrical System Type
03 · Beyond Single-Pole UKK · Multi-Pole & Rail-Type Series

K-Series & Modular Power Distribution Blocks

Alongside our flagship single-pole UKK 80A–500A blocks, VIOX manufactures complete multi-pole K-Series neutral/phase distribution blocks and high-current UTJ5 rail-type junction blocks for space-constrained sub-distribution enclosures.

When panel builders assemble compact 2-pole or 4-pole lighting and commercial distribution boards where horizontal DIN-rail space is tighter than vertical depth, the K-Series modular distribution block stacks 2 or 4 stepped brass bars inside a single insulated enclosure with color-coded phase barriers. For industrial feeder branches that require high mechanical pull-out retention directly on TS35 rail, the UTJ5 rail-type junction block series delivers oversized screw clamping and clear terminal numbering for rapid maintenance sign-off.

04 · Engineering Sizing Checklist & Internal Busbar Topology

How to Select a Power Distribution Block from Your Conductor Schedule

Follow these five engineering checks to size an AC or DC electrical power block accurately from your panel’s single-line diagram and cable schedule.

UKK Bus Topology1-In 6-Out (80A–160A) vs. 1-In 11-Out (250A–500A) Solid Brass Splitting
IEC 60947-7-1 · UL 1059 · IP20 Cover
UKK 80A / 125A / 160A — 1-IN 6-OUT 1 × Main In 16 / 35 / 70 mm² مطلي بالقصدير شريط نحاسي 6 × Branch Out 6–16 mm² Feeds To MCBs / Relays Compact 1-Pole Width · Dovetail Snap into 3P / 3P+N UKK 250A / 400A / 500A — 1-IN 11-OUT 1 × Heavy In 120 / 185 / 240 mm² Heavy Brass Core (500A) 11 × Branch Out 2×35 + 5×16 + 4×10 MCC & Solar Feeds 690V AC / 1000V DC · Dual TS35 DIN + M6 Panel Screw

1. Main Current & 125% Derating

Size the block’s rated current at least 1.25× above continuous feeder current (e.g., use UKK-160A for a 120A continuous feeder) to keep brass temperature rise well below IEC 60947-7-1 limits inside sealed enclosures.

2. Input / Output mm² & AWG

Match both the largest incoming cable cross-section (16 to 240 mm²) and every outgoing branch wire size. Always crimp ferrules on fine-stranded flexible conductors before torquing hex screws.

3. Pole Count & Color Coding

Snap single-pole UKK units into 2P (DC +/-), 3P (L1/L2/L3), or 3P+N+PE banks using Blue, Red, Yellow, and Green housings—or select a compact 4P K-Series multi-bar modular block.

4. AC/DC Voltage & Standards

تحقق Ui = 690V AC / 1000V DC insulation clearance for solar PV and BESS cabinets, and confirm IEC 60947-7-1, UL 1059, or feeder-side UL 1953 compliance with your local inspector.

05 · Hardware Architecture Comparison & Sister Components

كتلة توزيع الطاقة مقابل كتلة الأطراف مقابل قضيب التوصيل

Compare UKK single-pole blocks, modular multi-pole blocks, standard كتل طرفية DIN السكك الحديدية DINو قضبان التوصيل المشطية النحاسية to pick the lowest-cost, cleanest panel architecture.

Engineering comparison: UKK Power Distribution Blocks vs. Modular Multi-Pole Blocks vs. Standard Terminal Blocks vs. Copper Busbars
Engineering Criterion UKK Power Distribution Block (80A–500A) K-Series / UTJ5 Modular Block Standard DIN Terminal Block (UK / ST / PT) Insulated Copper Busbar
التصنيف الحالي النموذجي 80A to 500A per pole 63A to 250A multi-bar / rail 24A to 125A (1-to-1 feed-through) 63A to 125A (MCB comb) · 400A+ bar
Branching Density 1-in-6 or 1-in-11 out in one body 2P / 4P grouped phase + neutral taps Requires external jumper combs Fixed 18 mm pitch for MCB rows
Incoming Cable Size 16 mm² up to 240 mm² (6 AWG–500 kcmil) 10 mm² to 70 mm² 0.5 mm² to 35 mm² Feed-in terminal or crimped cable lug
IP20 Finger-Safe Cover Built-in hinged transparent PC lid Snap-on transparent barrier cover Touch-safe recessed screw channels Exposed without end caps / shrouds
Best Panel Role Main feeder splitting in switchgear, MCCs & 1000V DC solar boxes Compact sub-panels & neutral/phase grouped distribution Control I/O, PLC marshalling & individual load terminations Linking adjacent 1P–4P MCBs & RCBOs on one DIN rail
VIOX Hub Link Explore UKK 80A–500A ↑ Explore K-Series & UTJ5 ↑ DIN Terminal Blocks → قضبان توصيل مشطية لـ MCB →

Complete Your Feeder Termination Hardware

When wiring 35–240 mm² incoming cables into UKK-125A through UKK-500A blocks or main MCCB lugs, pair your distribution blocks with VIOX DT/DTL copper & bimetallic cable lugs, route downstream breaker rows with insulated MCB comb busbars, and organize control-circuit branches with UK/ST/PT DIN rail terminal blocks on one consolidated OEM factory shipment.

06 · Field Applications, 100% Factory QC & OEM Supply

Industrial, Switchgear & Solar DC Applications

Where electrical engineers, panel builders, and EPC contractors deploy VIOX UKK and modular power distribution blocks worldwide.

Switchgear & Main Incoming Feeders

Split a 185–240 mm² incoming MCCB feeder via UKK-400A / UKK-500A (1-in-11-out) cleanly across motor starter rows, VFD drives, and auxiliary transformer branches without custom copper bar fabrication.

1000V DC Solar PV & BESS Combiners

Combine parallel DC string fuses or split battery rack feeders using 1000V DC rated UKK power distribution blocks in Red (+) and Blue/Black (−) housings inside outdoor IP65 combiner boxes.

OEM Control Panels & HVAC Chiller Skids

Use compact UKK-80A / 125A / 160A و K-Series blocks on 35 mm DIN rail to feed compressors, condenser fans, and control transformers with full IP20 maintenance safety.

Evaluation Samples2–5 pcs/rating dispatched in 3–5 business days for torque, wire-fit & DIN-rail testing.
Mixed-Amp & Color MOQMix 80A–500A ratings and 4 colors from $1,000–$2,000 · Production lead time 10–18 days.
Export & WarrantyEXW / FOB Ningbo or Shanghai · 2–3 year factory replacement warranty · OEM laser print.
07 · Technical & OEM Sourcing FAQ

Power Distribution Block & UKK Selection FAQ

DC & Solar Can UKK power distribution blocks be used for DC solar and battery systems?

Yes. VIOX UKK 80A–500A power distribution blocks are rated up to 1000V DC (690V AC) under IEC 60947-7-1 with PA66 UL94 V-0 flame-retardant housings and high creepage clearance. They are widely used inside 1000V DC solar PV combiner boxes, battery energy storage (BESS) cabinets, and DC EV charging distribution rails when sized with a 125% continuous-duty current margin.

UKK Sizing How do I choose between UKK 80A, 125A, 160A, 250A, 400A, and 500A?

Start with both your main feeder current (applying a 1.25× continuous-load factor) and your incoming cable cross-section. UKK-80A accepts up to 16 mm², UKK-125A accepts 35 mm², and UKK-160A accepts 70 mm² in a 1-in-6-out layout. When you need 7 to 11 outgoing branch circuits or heavy feeders up to 120 mm² (UKK-250A), 185 mm² (UKK-400A), or 240 mm² (UKK-500A), step up to the 1-in-11-out series.

DIN vs. Screw Do VIOX UKK power distribution blocks mount on 35mm DIN rail or panel backplates?

Every VIOX UKK power distribution block (80A through 500A) supports dual mounting: snap directly onto standard 35 mm TS35 DIN rail for fast cabinet assembly, or bolt directly to a steel backplate using the integrated M5/M6 mounting holes for high-vibration or heavy 120–240 mm² cable terminations.

Multi-Pole How do I build a 3-phase + neutral electrical power block assembly using UKK blocks?

Single-pole UKK blocks feature dovetail interlocking slots on the housing sides so you can snap 3 or 4 units together into a rigid 3P or 3P+N distribution assembly. VIOX stocks Blue (Neutral), Red/Yellow (Phases L1/L2/L3), and Green (PE Earth) housings across 80A–500A for instant visual circuit identification.

Copper & Aluminum Can UKK power distribution blocks terminate both fine-stranded flexible wire and rigid cables?

Yes. VIOX UKK brass conductor blocks accommodate solid, stranded, and fine-stranded copper conductors. For fine-stranded flexible cables (Class 5/6), always crimp insulated or uninsulated copper bootlace ferrules before tightening the hex socket screw to the specified torque to prevent strand splaying and hot spots.

المعايير What is the difference between IEC 60947-7-1, UL 1059, and UL 1953 for power distribution blocks?

IEC 60947-7-1 governs low-voltage terminal and distribution blocks globally, specifying temperature rise, short-time withstand current, and dielectric strength up to 1000V. In North America, UL 1059 covers industrial control-panel terminal blocks (typically on the load side of branch protection), while UL 1953 specifies feeder-circuit power distribution blocks with higher spacing and SCCR requirements.

Direct Factory Power Distribution Block Supply

Need UKK 80A–500A, K-Series or UTJ5 Blocks for Your Next Panel BOM?

Send your amp ratings, color quantities (Blue / Red / Green / Yellow), and OEM branding needs. VIOX factory engineering replies with CAD drawings and wholesale pricing within 24 hours.

80A–500A Full 25-SKU Stock 690V AC / 1000V DC Rated Mixed-Color OEM Cartons Ready