VAF3-40M Magnetic Arc Fault Detection Device

The VIOX VAF3-40M magnetic arc fault detection device combines arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for 240 V AC, 50 Hz final circuits, it is available in 6-40 A ratings, B or C tripping characteristics and 10 or 30 mA sensitivities for residential and commercial installations.

Rated Current
6-40 A
Residual Current
10, 30 mA
Tripping Characteristic
B, C
Short-Circuit Current
6 kA

Overview

The VAF3-40M is a magnetic arc fault detection device combining arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for AC 50 Hz final circuits, it has a rated voltage of 240 V AC and is available in rated currents from 6 A to 40 A. The 1P+N device offers B or C overcurrent tripping characteristics and 10 mA or 30 mA residual-current sensitivities. It is intended for residential and commercial final circuits requiring combined protection against arc faults, electric shock, overload and short circuits.

Features

  • Magnetic version with integrated arc-fault, Type A residual-current, overload and short-circuit protection.
  • Compliant with IEC/EN 61009-1 and IEC/EN 62606.
  • Rated-current options from 6 A to 40 A.
  • B and C overcurrent tripping characteristics.
  • 10 mA and 30 mA residual-current sensitivities.
  • Load-disconnect contact with 6 kA rated short-circuit current.

Specifications

Electrical Data

Parameter Specification
Rated current (In) 6, 10, 13, 16, 20, 25, 32, 40 A
Rated voltage (Ue) 240 V AC
Operating frequency 50 Hz
Minimum test-circuit operating voltage 196 V
Maximum test-circuit operating voltage 253 V
Rated insulation voltage (Ui) 250 V
Rated impulse withstand voltage (Uimp) 4 kV
Rated short-circuit current 6 kA
Maximum total rated switching capacity 6 kA
Surge-current withstand strength 0.25 kA
Power loss per current path 3 W
Short-circuit back-up fuse (SCPD) 100 A
Back-up fuse type gG
Overvoltage category III

Protection Data

Parameter Specification
Product configuration AFDD with integrated Type A residual-current, overload and short-circuit protection
Number of poles 1P+N
Residual-current type Type A
Rated residual operating current (IΔn) 10, 30 mA
Overcurrent tripping characteristic B, C
Load-circuit specification Load-disconnect contact

Installation Data

Parameter Specification
Terminal type Screw-type terminals; top or bottom connection on the load circuit
Neutral conductor position Left or right
Maximum connected cable length 70 m between the distribution board and the furthest socket outlet
Terminal clamping capacity 1-25 mm²
Terminal tightening torque 2-2.4 N·m

Standards Data

Parameter Specification
Applicable standards IEC/EN 61009-1; IEC/EN 62606

Selection Guide

Code position Meaning Catalog reference
V VIOX identification V
AF Arc-fault protection product family AF
3 Design series 3
40 Maximum frame current 40
M Magnetic version M
C16 C tripping characteristic and rated current 16 A
A30 Type A residual-current protection 30 mA

Rated Current

Select a listed rating from 6 A to 40 A to match the final-circuit rating.

Tripping Characteristic

Select a B or C overcurrent tripping characteristic according to the circuit requirements.

Residual Sensitivity

Select a Type A residual operating-current sensitivity of 10 mA or 30 mA.

Applications

  • Residential final circuits.
  • Commercial final circuits.
  • Circuits requiring combined arc-fault and electric-shock protection.
  • Circuits requiring combined overload and short-circuit protection.

Installation

  • Use screw-type terminals with top or bottom connection on the load circuit.
  • Confirm whether the selected configuration places the neutral conductor on the left or right.
  • Use conductors within the listed terminal clamping capacity of 1-25 mm².
  • Apply the listed terminal tightening torque of 2-2.4 N·m.
  • Keep the connected cable length within 70 m between the distribution board and the furthest socket outlet.
  • Use the listed 100 A gG short-circuit back-up fuse.

FAQ

What distinguishes the VAF3-40M?

The catalog identifies the VAF3-40M as the magnetic version of the arc fault detection device.

Which protection functions are integrated?

It combines arc-fault detection with Type A residual-current, overload and short-circuit protection.

Which rated currents and tripping characteristics are available?

The catalog lists 6, 10, 13, 16, 20, 25, 32 and 40 A ratings with B or C overcurrent tripping characteristics.

Which residual-current sensitivities are offered?

The VAF3-40M provides Type A residual-current protection with 10 mA or 30 mA sensitivity.

What is the rated short-circuit current?

The rated short-circuit current is 6 kA.

Which standards are listed for the VAF3-40M?

The applicable standards are IEC/EN 61009-1 and IEC/EN 62606.