Breather Vent Plugs (Metal & Nylon) IP68 ePTFE Enclosure Pressure Equalization & Anti-Condensation Valves
Protect outdoor electrical cabinets, LED luminaires, EV chargers, and solar inverters from vacuum moisture ingress. VIOX manufactures screw-in 304/316L Stainless Steel, Nickel-Plated Brass, Anodized Aluminum, Black Metal, and PA66 Nylon breather vent plugs delivering up to 2,200 ml/min @ 70 mbar airflow across M6–M40, PG, G, and NPT threads.
Compare VIOX Stainless Steel, Brass, Aluminum & PA66 Breather Vent Plugs
Filter our full screw-in breather vent plug catalog by housing material, then compare operating temperature, airflow rate, and salt-spray ratings in the engineering matrix.
Вентиляционная пробка из нержавеющей стали
304/316L Marine & Washdown- Материал
- 304 / 316L Stainless Steel
- Threads
- Metric, PG, G (PF), NPT
- Диапазон температур
- от -40°C до +125°C
- Защита
- IP65–IP68 · 2,200 ml/min
High-Temp Metal Breather Vent Plug
Nickel-Plated Brass · +250°C- Материал
- Nickel-Plated Brass + Silicone
- Threads
- Metric, PG, G (PF), NPT
- Диапазон температур
- -40°C to +250°C
- Защита
- IP67–IP68 · 5 bar WEP
PA66 Nylon Breather Vent Plug
UV-Stabilized PA66 + ePTFE- Материал
- PA66 Nylon + ePTFE
- Threads
- M6–M32, PG, G, NPT
- Диапазон температур
- -40°C to +100°C (120°C peak)
- Защита
- IP67–IP68 (2m / 60 min)
Вентиляционная пробка из алюминиевого сплава
Lightweight LED & Telecom- Материал
- Anodized Aluminum Alloy
- Threads
- Metric, PG, G (PF), NPT
- Диапазон температур
- от -40°C до +125°C
- Защита
- IP65–IP68 · 2,200 ml/min
Nickel-Plated Brass Breather Vent Plug
Heavy Industrial Control Cabinet- Материал
- Nickel-Plated Copper / Brass
- Threads
- Metric, PG, G (PF), NPT
- Диапазон температур
- от -40°C до +125°C
- Защита
- IP65–IP68 · 2,200 ml/min
Черная металлическая заглушка вентиляционного отверстия
Matte Black Architectural / EV- Материал
- Black Coated Metal + ePTFE
- Threads
- Metric, PG, G (PF), NPT
- Диапазон температур
- от -40°C до +125°C
- Защита
- IP65–IP68 · 2,200 ml/min
Nylon Breather Vent Plug (V1)
Low-Profile Compact PA66- Материал
- PA66 Nylon + ePTFE
- Threads
- M6–M12, PG7–PG13.5, NPT
- Диапазон температур
- от -40°C до +100°C
- Защита
- IP67–IP68 (2m / 60 min)
Nickel-Plated Brass Vent Plug (V1)
Compact Hex Metal Housing- Материал
- Никелированная латунь
- Threads
- Metric, PG, G (PF), NPT
- Диапазон температур
- от -40°C до +125°C
- Защита
- IP65–IP68 · 2,200 ml/min
Aluminum Alloy Vent Plug (V1)
Low-Profile Anodized Aluminum- Материал
- Anodized Aluminum Alloy
- Threads
- Metric, PG, G (PF), NPT
- Диапазон температур
- от -40°C до +125°C
- Защита
- IP65–IP68 · 2,200 ml/min
Aluminum Alloy Vent Plug (Series 2)
High-Flow Enclosure Vent- Материал
- Anodized Aluminum Alloy
- Threads
- Metric, PG, G (PF), NPT
- Диапазон температур
- от -40°C до +125°C
- Защита
- IP65–IP68 · 2,200 ml/min
| Материал корпуса | Диапазон температур | Airflow (@ 70 mbar) | Water Entry / IP | Salt Spray (IEC 68-2-11) | Best-Fit Applications |
|---|---|---|---|---|---|
| 304 / 316L Stainless Steel | от -40°C до +125°C | 2,200 ml/min | IP65–IP68 (>10 kPa) | 96h+ Marine Grade | Offshore wind, marine cabinets, food & chemical washdown |
| High-Temp Nickel Brass | -40°C to +250°C | 0.2 ml – 12 L/h @ 7 kPa | IP67–IP68 (5 бар) | Nickel corrosion shield | High-wattage LED floodlights, motor housings, hot machinery |
| Никелированная латунь | от -40°C до +125°C | 2,200 ml/min | IP65–IP68 (>10 kPa) | 96 hours | EV chargers, steel control cabinets, railway & outdoor switchgear |
| Anodized Aluminum Alloy | от -40°C до +125°C | 2,200 ml/min | IP65–IP68 (>10 kPa) | 96 hours | Die-cast LED street lights, 5G telecom radios, solar inverters |
| Black Coated Metal | от -40°C до +125°C | 2,200 ml/min | IP65–IP68 (>10 kPa) | 96 hours | Architectural black luminaires, EV pedestals, outdoor CCTV |
| PA66 UV Nylon | от -40°C до +100°C | Up to 1,500 ml/min | IP67–IP68 (2m / 60 min) | Zero rust / non-metallic | Polycarbonate junction boxes, PV combiner boxes, IoT sensors |
Match Breather Vent Plug Count, Material & Thread to Your Enclosure
Set your sealed cabinet internal volume, environmental exposure, and thread standard to size the right VIOX breather vent plug configuration.
How a Screw-In ePTFE Breather Vent Plug Stops Enclosure Condensation
Based directly on VIOX factory Section A-A engineering drawings: inspect the internal waterproof breathable ePTFE membrane seated behind the slotted hex head, then toggle field conditions below.
Unvented Sealed Enclosure (No Plug)
CONDENSATION RISKVIOX ePTFE Breather Vent Plug
DRY · IP68 PROTECTEDUp to 2,200 ml/min High Airflow
Rapidly equalizes large enclosures (25 L–150 L+) during sudden rain storms or rapid LED/inverter cool-down—where small cable-gland vents alone cannot keep up.
Hydrophobic & Oleophobic ePTFE
Sub-micron membrane pores pass air and water vapor continuously while repelling liquid rain, high-pressure washdown spray, oil mist, and coastal salt fog.
Extends Enclosure Gasket Life
Eliminating daily ±120 mbar pressure cycles stops cabinet door seals from ballooning and fatiguing—preventing premature IP68 field failures.
Quotation Variables, ePTFE Membrane Testing & OEM Supply
In-house CNC turning (316L stainless, brass, aluminum), PA66 injection molding, and ultrasonic ePTFE membrane welding with full batch traceability.
1. Airflow & WEP Verification
Every production lot is audited for 2,200 ml/min @ 70 mbar airflow consistency and IP68 water-entry pressure (>10 kPa to 5 bar).
2. 96h Salt Spray (IEC 68-2-11)
Metal, anodized aluminum, and 304/316L stainless steel housings undergo salt-fog corrosion verification for coastal and marine deployment.
3. Custom Threads & O-Rings
Standard Metric (M6–M40), PG, G (PF), and NPT threads stocked with EPDM, Viton, or +250°C high-temperature silicone O-rings.
4. Consolidated Venting POs
Ship breather vent plugs together with Дышащие кабельные вводы и Industrial Cable Glands on one invoice.
Generate Your Breather Vent Plug RFQ in 30 Seconds
Select housing material, thread size, ePTFE membrane grade, and order quantity, then copy or attach directly to the VIOX sales form.
Breather Vent Plug & Condensation Prevention Guides
Engineering articles authored by VIOX enclosure protection specialists covering ePTFE physics, airflow sizing, and breather plug selection.
What Is a Breather Vent Plug? ePTFE & IP68 Explained
How screw-in ePTFE pressure-equalization valves protect outdoor enclosures from vacuum leaks and condensation.
Explore Guide →Breather Plug vs. Breathable Cable Gland: Which Is Best?
Engineering comparison of dedicated breather vent plugs vs. 2-in-1 breathable cable glands by cabinet volume.
Explore Guide →Vented Electrical Enclosure Design & Placement Guide
Sidewall mounting orientation, airflow sizing, and thermal management for outdoor control cabinets.
Explore Guide →Stop Condensation Damage: Complete Selection Guide
Practical sizing rules for dew-point prevention, salt-spray exposure, and hydrophobic vs. oleophobic membranes.
Explore Guide →VIOX Breathable Cable Glands (Metal & Nylon IP68)
Combine IP68 cable strain relief and ePTFE venting in one single panel knockout for compact boxes.
Explore Guide →Complete Industrial & Ex d Cable Gland Lineup
Browse BDM armored flameproof glands, EMC 360° brass, 316L marine, and PA66 nylon cable glands.
Explore Guide →Breather Vent Plug Selection & Installation Questions
Принцип работы How does an IP68 breather vent plug equalize pressure while blocking rain and dust?
A VIOX breather vent plug seats a hydrophobic and oleophobic expanded PTFE (ePTFE) microporous membrane flat across the internal airway bore behind a slotted protective hex head. Its sub-micron pores allow air and water vapor molecules to flow freely (up to 2,200 ml/min @ 70 mbar) to equalize pressure, while blocking liquid water droplets, dust, and salt mist at IP67/IP68 ratings.
Airflow Sizing How do I size breather vent plug quantity and thread for my enclosure volume?
Compact housings under 5 L (LED luminaires, sensors, IoT boxes) typically use one M6×1 or M12×1.5 vent plug. Medium boxes from 5–25 L (PV combiners, EV chargers) perform best with one high-flow M12/M16 vent rated at 2,200 ml/min @ 70 mbar. Cabinets over 25–100 L should install two vents (low inlet + upper exhaust) for rapid thermal-cycle equalization.
Vent vs. Gland When should I use a breather vent plug instead of a breathable cable gland?
Specify a standalone breather vent plug when enclosure volume exceeds 25 L, when maximum airflow (2,200 ml/min @ 70 mbar) is needed, or when retrofitting an already-wired cabinet. Choose a VIOX breathable cable gland on compact boxes under 15–20 L when saving a second knockout hole is the priority.
Материалы How do I choose between PA66 nylon, aluminum alloy, nickel-plated brass, and 316L stainless steel?
Use PA66 nylon for polycarbonate boxes, UV outdoor LEDs, and cost-sensitive solar housings (-40°C to +100°C). Use anodized aluminum for lightweight die-cast luminaires and 5G telecom enclosures. Specify nickel-plated brass for rugged steel cabinets (or up to +250°C with our high-temp silicone series), and 304/316L stainless steel for coastal salt-spray, offshore, and chemical washdown environments.
Установка Where should a breather vent plug be mounted on an outdoor electrical cabinet?
Mount the breather vent plug on a sheltered vertical sidewall—never face-up on a flat roof where standing water, mud, or ice can pool over the vent slots. Compress the silicone or EPDM O-ring evenly against a clean, burr-free panel surface using the supplied locknut.
Membrane Grade What is the difference between hydrophobic and oleophobic ePTFE membranes?
Hydrophobic ePTFE repels liquid water and rain. Oleophobic ePTFE adds a low-surface-energy treatment that also repels low-surface-tension fluids such as hydraulic oil mist, cutting fluids, cleaning detergents, and automotive fuels—preventing membrane pore wetting in factory automation, EV chargers, and marine environments.
Need Breather Vent Plug CAD Drawings or Sample Kits?
Share your enclosure volume, operating temperature, thread size, and salt-spray or oil exposure. VIOX engineers will reply with 2D/3D CAD files, airflow curves, and factory pricing within 24 hours.