VIOX Electric
Language

VIOX CJX2s Contactor Accessories

Select compatible accessories for VIOX CJX2s and CJX2s-M
contactors.

  • KAT/KAS auxiliary contact blocks
  • KTD pneumatic delay heads and KMI interlocks
  • FS coil suppression modules and KDC dust covers
  • JR28s thermal overload relays with discrete adjustment ranges

Overview

VIOX CJX2s contactor accessories support auxiliary signalling,
time-delay control, interlocking, coil transient suppression and motor
overload protection. Select each accessory by its function and the exact
contactor frame; the items shown are individually selected components,
not a bundled kit.

Auxiliary Contact Blocks

KAT blocks mount on the front/top of the contactor. KAS blocks are
side-mounted. NO and NC quantities refer to auxiliary contacts.

Miniature model Standard model NO NC
KAT-M20 KAT-20 2 0
KAT-M11 KAT-11 1 1
KAT-M02 KAT-02 0 2
KAT-M40 KAT-40 4 0
KAT-M31 KAT-31 3 1
KAT-M22 KAT-22 2 2
KAT-M13 KAT-13 1 3
KAT-M04 KAT-04 0 4
  • KAT-M: CJX2s-M06–M16 miniature contactors.
  • Standard KAT: CJX2s-09–630, according to the supplied compatibility
    table.
  • KAS-20: 2NO; KAS-11: 1NO + 1NC; KAS-02: 2NC. Listed for
    CJX2s-09–630.

Pneumatic Time-Delay Heads

Model Delay function Adjustment range
KTD-C1 On-delay 0.1–3 s
KTD-C2 On-delay 0.1–30 s
KTD-C3 On-delay 10–180 s
KTD-D1 Off-delay 0.1–3 s
KTD-D2 Off-delay 0.1–30 s
KTD-D3 Off-delay 10–180 s

The KTD heads provide pneumatic time delay with 1NO + 1NC auxiliary
contacts. The catalogue lists CJX2s-09–630 compatibility.

Interlocks and Dust Covers

Accessory Catalogue compatibility
KMI mechanical interlock CJX2s-09–38
KMI electrical interlock CJX2s-09–95
KDC-1 front dust cover CJX2s-09–38
KDC-2 front dust cover CJX2s-40–95

Select interlocks for the actual paired-contactor arrangement. A
front dust cover does not establish a new enclosure IP rating.

Coil Surge Suppression
Modules

Module Contactor frame
FS-M CJX2s-M06–M16
FS-18 CJX2s-09–18
FS-32 CJX2s-25–32
FS-65 CJX2s-40–65
FS-95 CJX2s-80–95

The catalogue lists AC/DC voltage bands of 24–48 V, 100–250 V and
380–440 V. Select the module voltage version to match the coil supply as
well as the contactor frame. These coil suppression accessories are not
distribution-panel surge protective devices.

Thermal Overload Relays

Relay Available adjustment ranges (A) Listed contactor frames
JR28s-25 0.1–0.16; 0.16–0.25; 0.25–0.4; 0.4–0.63; 0.63–1; 1–1.6; 1.25–2;
1.6–2.5; 2.5–4; 4–6; 5.5–8; 7–10; 9–13; 12–18; 17–25
CJX2s-09, 12, 18, 25
JR28s-36 23–32; 28–36 CJX2s-32, 38
JR28s-93 23–32; 30–40; 37–50; 48–65; 55–70; 63–80; 80–93 CJX2s-40, 50, 65, 80, 95

Each adjustment range is a separate selection. Choose a relay range
that includes the motor nameplate current and coordinate it with the
contactor and short-circuit protective device.

Ordering Information

Provide the exact contactor model, accessory model, required NO/NC
arrangement, delay range or relay current range, coil supply voltage
where applicable, and quantity. Confirm mounting compatibility for the
supplied contactor version before ordering.

Need a Product Quote?
Let’s Build It Together.

Send us the product model, technical ratings, quantity, and OEM requirements. Our team will review your application and respond within one business day.

Request a Quote