VIOX ELECTRIC
언어

VIOX CJX2s 접촉기 액세서리

Select compatible accessories for VIOX CJX2s and CJX2s-M
contactors.

  • KAT/KAS auxiliary contact blocks
  • KTD pneumatic delay heads and KMI interlocks
  • FS coil suppression modules and KDC dust covers
  • JR28s thermal overload relays with discrete adjustment ranges

개요

VIOX CJX2s contactor accessories support auxiliary signalling,
time-delay control, interlocking, coil transient suppression and motor
overload protection. Select each accessory by its function and the exact
contactor frame; the items shown are individually selected components,
not a bundled kit.

보조 접점 블록

KAT blocks mount on the front/top of the contactor. KAS blocks are
side-mounted. NO and NC quantities refer to auxiliary contacts.

Miniature model Standard model NO NC
KAT-M20 KAT-20 2 0
KAT-M11 KAT-11 1 1
KAT-M02 KAT-02 0 2
KAT-M40 KAT-40 4 0
KAT-M31 KAT-31 3 1
KAT-M22 KAT-22 2 2
KAT-M13 KAT-13 1 3
KAT-M04 KAT-04 0 4
  • KAT-M: CJX2s-M06–M16 miniature contactors.
  • Standard KAT: CJX2s-09–630, according to the supplied compatibility
    table.
  • KAS-20: 2NO; KAS-11: 1NO + 1NC; KAS-02: 2NC. Listed for
    CJX2s-09–630.

Pneumatic Time-Delay Heads

모델 Delay function 조정 범위
KTD-C1 온 지연 0.1–3 s
KTD-C2 온 지연 0.1–30 s
KTD-C3 온 지연 10–180 s
KTD-D1 오프 지연 0.1–3 s
KTD-D2 오프 지연 0.1–30 s
KTD-D3 오프 지연 10–180 s

The KTD heads provide pneumatic time delay with 1NO + 1NC auxiliary
contacts. The catalogue lists CJX2s-09–630 compatibility.

Interlocks and Dust Covers

액세서리 Catalogue compatibility
KMI mechanical interlock CJX2s-09–38
KMI electrical interlock CJX2s-09–95
KDC-1 front dust cover CJX2s-09–38
KDC-2 front dust cover CJX2s-40–95

Select interlocks for the actual paired-contactor arrangement. A
front dust cover does not establish a new enclosure IP rating.

Coil Surge Suppression
모듈

모듈 Contactor frame
FS-M CJX2s-M06–M16
FS-18 CJX2s-09–18
FS-32 CJX2s-25–32
FS-65 CJX2s-40–65
FS-95 CJX2s-80–95

The catalogue lists AC/DC voltage bands of 24–48 V, 100–250 V and
380–440 V. Select the module voltage version to match the coil supply as
well as the contactor frame. These coil suppression accessories are not
distribution-panel surge protective devices.

열 과부하 릴레이

릴레이 Available adjustment ranges (A) Listed contactor frames
JR28s-25 0.1–0.16; 0.16–0.25; 0.25–0.4; 0.4–0.63; 0.63–1; 1–1.6; 1.25–2;
1.6–2.5; 2.5–4; 4–6; 5.5–8; 7–10; 9–13; 12–18; 17–25
CJX2s-09, 12, 18, 25
JR28s-36 23–32; 28–36 CJX2s-32, 38
JR28s-93 23–32; 30–40; 37–50; 48–65; 55–70; 63–80; 80–93 CJX2s-40, 50, 65, 80, 95

Each adjustment range is a separate selection. Choose a relay range
that includes the motor nameplate current and coordinate it with the
contactor and short-circuit protective device.

주문 정보

Provide the exact contactor model, accessory model, required NO/NC
arrangement, delay range or relay current range, coil supply voltage
where applicable, and quantity. Confirm mounting compatibility for the
supplied contactor version before ordering.

제품 견적이 필요하신가요?
함께 만들어 갑시다.

제품 모델, 기술 정격, 수량 및 OEM 요구 사항을 보내주십시오. 당사 팀에서 귀하의 애플리케이션을 검토한 후 영업일 기준 1일 이내에 답변해 드리겠습니다.

견적 요청하기