VIOX Electric
Language

Perangkat Deteksi Busur Api Magnetik VAF3-40M

The VIOX VAF3-40M magnetic arc fault detection device combines arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for 240 V AC, 50 Hz final circuits, it is available in 6-40 A ratings, B or C tripping characteristics and 10 or 30 mA sensitivities for residential and commercial installations.

Nilai Saat Ini
6-40 A
Arus Sisa
10, 30 mA
Karakteristik pemutusan
B, C
Arus Hubung Singkat
6 kA

Ikhtisar

The VAF3-40M is a magnetic arc fault detection device combining arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for AC 50 Hz final circuits, it has a rated voltage of 240 V AC and is available in rated currents from 6 A to 40 A. The 1P+N device offers B or C overcurrent tripping characteristics and 10 mA or 30 mA residual-current sensitivities. It is intended for residential and commercial final circuits requiring combined protection against arc faults, electric shock, overload and short circuits.

Fitur

  • Magnetic version with integrated arc-fault, Type A residual-current, overload and short-circuit protection.
  • Sesuai dengan IEC/EN 61009-1 dan IEC/EN 62606.
  • Pilihan arus pengenal dari 6 A hingga 40 A.
  • Karakteristik pemutusan arus lebih B dan C.
  • Sensitivitas arus sisa 10 mA dan 30 mA.
  • Kontak pemutus beban dengan arus hubung singkat terukur 6 kA.

Spesifikasi

Data Kelistrikan

Parameter Spesifikasi
Arus nominal (In) 6, 10, 13, 16, 20, 25, 32, 40 A
Tegangan pengenal (Ue) 240 V AC
Frekuensi operasi 50 Hz
Tegangan operasi sirkuit uji minimum 196 V
Tegangan operasi sirkuit uji maksimum 253 V
Tegangan isolasi terukur (Ui) 250 V
Nilai tegangan tahan impuls (Uimp) : 4 kV
Arus hubung singkat terukur 6 kA
Kapasitas sakelar terukur total maksimum 6 kA
Kekuatan ketahanan arus lonjakan 0.25 kA
Kehilangan daya per jalur arus 3 W
Sekering cadangan hubung singkat (SCPD) 100 A
Tipe sekering cadangan gG
Kategori tegangan lebih III

Data proteksi

Parameter Spesifikasi
Konfigurasi produk AFDD dengan proteksi arus sisa Tipe A, beban lebih, dan hubung singkat terintegrasi
Jumlah kutub 1P + N
Jenis arus sisa Tipe A
Arus operasi sisa terukur (IΔn) 10, 30 mA
Karakteristik pemutusan arus lebih B, C
Spesifikasi sirkuit beban Kontak pemutus beban

Data instalasi

Parameter Spesifikasi
Jenis terminal Terminal tipe sekrup; koneksi atas atau bawah pada sirkuit beban
Posisi konduktor netral Kiri atau kanan
Panjang kabel terhubung maksimum 70 m antara papan distribusi dan stopkontak terjauh
Kapasitas klem terminal 1-25 mm²
Torsi pengencangan terminal 2-2.4 N·m

Data standar

Parameter Spesifikasi
Standar yang berlaku IEC/EN 61009-1; IEC/EN 62606

Panduan Pemilihan

Posisi kode Arti Referensi katalog
V VIOX identification V
AF Keluarga produk proteksi gangguan busur AF
3 Design series 3
40 Arus rangka maksimum 40
M Magnetic version M
C16 Karakteristik pemutusan C dan arus pengenal 16 A
A30 Perlindungan arus sisa Tipe A 30 mA

Nilai Saat Ini

Pilih peringkat yang terdaftar dari 6 A hingga 40 A untuk menyesuaikan dengan peringkat sirkuit akhir.

Karakteristik pemutusan

Pilih karakteristik pemutusan arus lebih B atau C sesuai dengan kebutuhan sirkuit.

Sensitivitas Sisa

Pilih sensitivitas arus operasi sisa Tipe A sebesar 10 mA atau 30 mA.

Aplikasi

  • Sirkuit akhir residensial.
  • Sirkuit akhir komersial.
  • Circuits requiring combined arc-fault and electric-shock protection.
  • Circuits requiring combined overload and short-circuit protection.

Instalasi

  • Gunakan terminal tipe sekrup dengan koneksi atas atau bawah pada sirkuit beban.
  • Pastikan apakah konfigurasi yang dipilih menempatkan konduktor netral di sisi kiri atau kanan.
  • Gunakan konduktor dalam kapasitas jepit terminal yang tercantum sebesar 1-25 mm².
  • Terapkan torsi pengencangan terminal yang tercantum sebesar 2-2.4 N·m.
  • Jaga panjang kabel yang terhubung dalam jarak 70 m antara papan distribusi dan stopkontak terjauh.
  • Gunakan sekering cadangan hubung singkat 100 A gG yang terdaftar.

PERTANYAAN YANG SERING DIAJUKAN

What distinguishes the VAF3-40M?

The catalog identifies the VAF3-40M as the magnetic version of the arc fault detection device.

Which protection functions are integrated?

Ini menggabungkan deteksi gangguan busur dengan proteksi arus sisa Tipe A, beban lebih, dan hubung singkat.

Berapa arus pengenal dan karakteristik pemutusan yang tersedia?

Katalog tersebut mencantumkan rating 6, 10, 13, 16, 20, 25, 32, dan 40 A dengan karakteristik pemutusan arus lebih B atau C.

Berapa sensitivitas arus sisa yang ditawarkan?

The VAF3-40M provides Type A residual-current protection with 10 mA or 30 mA sensitivity.

What is the rated short-circuit current?

Arus hubung singkat terukur adalah 6 kA.

Which standards are listed for the VAF3-40M?

Standar yang berlaku adalah IEC/EN 61009-1 dan IEC/EN 62606.

Butuh Penawaran Produk?
Mari Kita Bangun Bersama.

Kirimkan model produk, peringkat teknis, kuantitas, dan persyaratan OEM kepada kami. Tim kami akan meninjau aplikasi Anda dan merespons dalam satu hari kerja.

Minta Penawaran