MCB Comb Busbars (Pin & Fork · 1P–4P) Insulated Copper Phase Distribution Busbars for IEC DIN-Rail MCBs, RCBOs & RCCBs
Cut distribution board wiring time by 70% while eliminating messy jumper loops. VIOX manufactures 18 precision copper comb busbar configurations across Pin-Type, Fork-Type (M5/M6), C45, and Closed-Shroud profiles—in 1P, 1P+N, 2P, 3P, 3P+N, and 4P ratings from 63A to 125A+.
Browse VIOX Fork-Type, Pin-Type, C45 & Closed-Shroud Comb Busbars
Filter by terminal geometry below to inspect exact pole configurations, copper cross-sections, and datasheets.
VIOX Fork-Type 1-Phase Busbar (M6)
Fork-Type · 1P · M6 Screw- Poles
- 1P (Single Phase)
- Ampacity
- 63A – 100A (10/16 mm²)
- Pitch / Len
- 17.8 mm · 1m Cuttable
- Material
- 99.9% T2 Copper + PVC/PA66
VIOX Fork-Type 2-Phase Busbar (M6)
Fork-Type · 2P · M6 Screw- Poles
- 2P (L1 + L2 / L+N)
- Ampacity
- 63A – 100A (10/16 mm²)
- Pitch / Len
- 17.8 mm · 1m Cuttable
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Fork-Type 3-Phase Busbar (M6)
Fork-Type · 3P · M6 Heavy- Poles
- 3P (L1 + L2 + L3)
- Ampacity
- 63A – 100A (10/16 mm²)
- Pitch / Len
- 17.8 mm · 1m Cuttable
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Fork-Type 3-Phase Busbar (M5)
Fork-Type · 3P · M5 Screw- Poles
- 3P (L1 + L2 + L3)
- Ampacity
- 63A – 80A (10 mm²)
- Pitch / Len
- 17.8 mm · M5 Fork Slot
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Fork-Type 3P+N Busbar (M6)
Fork-Type · 3P+N · M6 Screw- Poles
- 3P+N (4-Conductor)
- Ampacity
- 63A – 100A (10/16 mm²)
- Pitch / Len
- 17.8 mm · 1m Cuttable
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Fork-Type 4-Pole Busbar (M6)
Fork-Type · 4P · M6 Screw- Poles
- 4P (L1+L2+L3+N)
- Ampacity
- 63A – 100A (10/16 mm²)
- Pitch / Len
- 17.8 mm · 1m Cuttable
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Pin-Type 1-Phase Busbar
Pin-Type · 1P · Universal IEC- Poles
- 1P (Single Phase)
- Ampacity
- 63A – 100A (10/16 mm²)
- Pitch / Len
- 17.8 mm · 56–57 Pins/m
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Pin-Type 2-Phase Busbar
Pin-Type · 2P · Universal IEC- Poles
- 2P (L1 + L2 / L+N)
- Ampacity
- 63A – 100A (10/16 mm²)
- Pitch / Len
- 17.8 mm · 1m Cuttable
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Pin-Type 3-Phase Busbar
Pin-Type · 3P · Universal IEC- Poles
- 3P (L1 + L2 + L3)
- Ampacity
- 63A – 100A (10/16 mm²)
- Pitch / Len
- 17.8 mm · 1m Cuttable
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Pin-Type 4-Phase Busbar
Pin-Type · 4P · Universal IEC- Poles
- 4P (L1+L2+L3+N)
- Ampacity
- 63A – 100A (10/16 mm²)
- Pitch / Len
- 17.8 mm · 1m Cuttable
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Pin-Type 1P+N Busbar
Pin-Type · 1P+N · RCBO / DPN- Poles
- 1P+N (Compact 18 mm)
- Ampacity
- 63A – 80A
- Pitch / Len
- 9 mm / 17.8 mm RCBO Fit
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Pin-Type 1P+N Busbar (Long End)
Pin-Type · 1P+N · Extended Pin- Poles
- 1P+N + Long Feed Pin
- Ampacity
- 63A – 80A
- Pitch / Len
- Direct RCCB-to-MCB Bridge
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Pin-Type 1-Phase Busbar (C45)
C45 Series · 1P · Heavy Copper- Poles
- 1P (C45 / DZ47 Fit)
- Ampacity
- 63A – 100A
- Pitch / Len
- 17.8 mm Standard
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Pin-Type 2-Phase Busbar (C45)
C45 Series · 2P · Heavy Copper- Poles
- 2P (C45 / DZ47 Fit)
- Ampacity
- 63A – 100A
- Pitch / Len
- 17.8 mm Standard
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Pin-Type 3-Phase Busbar (C45)
C45 Series · 3P · Heavy Copper- Poles
- 3P (C45 / DZ47 Fit)
- Ampacity
- 63A – 100A
- Pitch / Len
- 17.8 mm Standard
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Pin-Type 4-Phase Busbar (C45)
C45 Series · 4P · Heavy Copper- Poles
- 4P (C45 / DZ47 Fit)
- Ampacity
- 63A – 100A
- Pitch / Len
- 17.8 mm Standard
- Material
- 99.9% T2 Copper + UL94 V-0
VIOX Pin-Type 2-Phase Closed Busbar
Closed Shroud · 2P · Enhanced IP20- Poles
- 2P Fully Enclosed Back
- Ampacity
- 63A – 100A
- Pitch / Len
- 17.8 mm · Pre-Cut / 1m
- Material
- 99.9% T2 Copper + Closed PA66
VIOX Pin-Type 3-Phase Closed Busbar
Closed Shroud · 3P · Enhanced IP20- Poles
- 3P Fully Enclosed Back
- Ampacity
- 63A – 100A
- Pitch / Len
- 17.8 mm · Pre-Cut / 1m
- Material
- 99.9% T2 Copper + Closed PA66
| Busbar Profile | Poles Available | Copper Section & Ampacity | Pitch & Length | Best-Fit Circuit Breakers |
|---|---|---|---|---|
| Pin-Type Universal | 1P, 1P+N, 2P, 3P, 4P | 10 / 16 mm² · 63A–100A (130A Center-Feed) | 17.8 mm · 1 m (54–57 mod) | Universal IEC box-clamp MCBs & RCBOs |
| Fork-Type (M5 / M6) | 1P, 2P, 3P, 3P+N, 4P | 10 / 16 mm² · 63A–100A (160A Center-Feed) | 17.8 mm · M5/M6 Fork Slot | Dual-terminal MCBs (leaves wire cage free) |
| C45 Pin Series | 1P, 2P, 3P, 4P | 10 / 16 mm² · 63A–100A | 17.8 mm · 1 m Cuttable | C45 / DZ47 modular circuit breakers |
| Closed-Shroud Pin | 2P, 3P | 10 / 16 mm² · 63A–100A | 17.8 mm · Enclosed Rear | Compact metal consumer units (high IP20) |
Match VIOX Busbar Profile, Cross-Section & Feed-In Connector
Choose your breaker clamp style, phase configuration, and total bank current to size the exact comb busbar and determine whether end-feed or center-feed is required.
Compare VIOX Pin-Type, Fork-Type & Closed-Shroud Comb Busbars
Inspect real VIOX copper busbar profiles side by side to confirm exact mechanical fit with your circuit breaker terminals.
Flat copper pins insert directly into universal MCB/RCBO cage clamps across 1P, 1P+N, 2P, 3P, and 4P layouts.
Inspect Pin-Type 3P →
U-shaped prongs seat cleanly under the MCB screw head so incoming feeder wires can use the full box clamp unobstructed.
Inspect Fork-Type M6 →
Fully enclosed rear insulation barrier maximizes creepage distance and touch safety inside tight metal enclosures.
Inspect Closed 3P →99.9% Pure T2 Electrolytic Copper
Low-resistance solid copper bars minimize continuous I²R heating compared to brass or copper-clad aluminum imitations.
70% Faster Distribution Board Wiring
Replaces dozens of hand-cut jumper wires with one rigid, vibration-proof comb busbar across up to 57 breaker poles.
Complete End-Cap & Feed-In System
Ships with matched insulated end caps, spare-tooth shock guards, and TB25 / TB50 feed-in connectors.
Generate Your Comb Busbar RFQ in 30 Seconds
Select Pin/Fork/Closed profile, pole count, copper cross-section, and cut length—copy or attach directly to VIOX sales.
Pin vs. Fork Busbar, Cutting & Panel Wiring Guides
In-depth technical guides authored by VIOX switchgear engineers.
Pin Type Busbar vs. Fork Type Busbar: Differences & Selection
Match Pin and Fork profiles to your breaker clamps and avoid installation interference.
Explore Guide →How to Cut and Insulate a Comb Busbar Correctly
Step-by-step copper recess trimming, deburring, and end-cap installation for 1-meter bars.
Explore Guide →Comb Busbar vs. Jumper Wire: Which Is Better for MCBs?
Compare panel assembly speed, thermal performance, and long-term contact reliability.
Explore Guide →MCB Busbar Compatibility Guide Across Circuit Breakers
17.8 mm module pitch, M5 vs. M6 fork slots, and 1P+N RCBO alignment rules.
Explore Guide →VIOX MCB Bus Bar Feed-In Connectors (TB25 / TB50)
Add touch-safe 25–50 mm² incoming power feed terminals for end-feed or center-feed banks.
Explore Guide →Why Is Your MCB Busbar Overheating? Causes & Fixes
Diagnose current bottlenecks, center-feed ampacity limits, and torque failures.
Explore Guide →MCB Comb Busbar Selection & Installation Questions
Pin vs. Fork How do I know whether my MCBs require a Pin-type or Fork-type comb busbar?
Check the bottom terminal of your circuit breaker: Pin-type busbars slide directly into standard rectangular box/cage clamps (universal for most IEC MCBs, RCBOs, and C45 breakers). Fork-type busbars (M5 or M6 U-shaped prongs) seat underneath the screw head of dual-terminal MCBs, leaving the main box clamp completely free for outgoing or incoming cables.
Ampacity & Center Feed What is the maximum current rating of a 10 mm² vs. 16 mm² MCB comb busbar?
With single-end feeding, a 10 mm² copper comb busbar typically carries up to 63 A and a 16 mm² bar carries 80 A–100 A. When center-fed using a VIOX TB25 or TB50 busbar feed-in connector, current splits equally left and right—allowing safe continuous capacity up to 100 A (10 mm²) or 130 A–160 A (16 mm²).
Cutting & End Caps Can 1-meter VIOX comb busbars be cut to length on site?
Yes. Standard 1-meter bars (54–57 modules at 17.8 mm pitch) can be cleanly cut to any pole count. Always trim the copper strip slightly recessed inside the insulation sheath, deburr the cut edge, and snap a VIOX insulated end cap onto every cut end to preserve full phase-to-phase creepage and IP20 finger safety.
Comb Busbar vs. Wire Why use an insulated copper comb busbar instead of daisy-chaining jumper wires?
Daisy-chaining jumper wires takes 3–4× longer to strip, ferrule, and torque, doubles the number of screw joints that can loosen over time, and creates messy heat-trapping wire loops. A single solid T2 copper comb busbar delivers uniform low-resistance power distribution in seconds.
Closed vs. Open Shroud When should I choose a Closed-Type Pin busbar over a standard open-back comb busbar?
Closed-type pin busbars feature a fully enclosed rear insulation jacket that prevents accidental contact during live panel inspection and eliminates stray flashover risk in compact metallic consumer units or high-humidity enclosures.
Custom Pre-Cut Does VIOX supply pre-cut 6-way, 12-way, or 18-way comb busbars with end caps pre-installed?
Yes. In addition to 1-meter standard lengths, VIOX factory-cuts custom pole counts (e.g., 6P, 12P, 18P, 24P) with pre-fitted end caps, tooth covers, and bundled TB25/TB50 feed-in connectors for distribution-board OEMs.
Need 1-Meter or Custom Pre-Cut Copper Comb Busbars?
Share your Pin/Fork requirement, pole count, copper cross-section, and target order quantity. VIOX factory engineers reply with drawings, samples, and tiered pricing within 24 hours.