VIOX 690VAC 100A Australia Type Clear HRC Cutout Fuse

Clear HRC VIOX 690VAC 100A Australia Type Clear HRC Cutout Fuse is designed to ensure a secure connection and low contact resistance throughout and is typically used to protect the supply to a flat or a dwelling and used as a service head. Glass-reinforced Polyester (DMC) material.

Serie VIOX
Clear
Tensione nominale
690VAC
Corrente nominale
100A
Standard
BS88 / IEC60269

Panoramica

Clear HRC VIOX 690VAC 100A Australia Type Clear HRC Cutout Fuse is designed to ensure a secure connection and low contact resistance throughout and is typically used to protect the supply to a flat or a dwelling and used as a service head. Glass-reinforced Polyester (DMC) material provides strength, durability, and excellent tracking resistance.

690VAC 100A Australia Type Clear HRC Cutout Fuse

Caratteristiche

  • High strength
  • Elevata durabilità
  • Excellent tracking resistance
  • 100A ampere ratings
  • Two wiring options
  • CB approved
  •  Service cutout, household use. Normally used to protect the supply to a flat or a dwelling. Used as a service head
  •  Secure connection and low contact resistance throughout

Specifiche tecniche

Clear Technical Specifications

Model / Size Tensione nominale (V) Corrente nominale (A) Recommended Fuse Link Model/Size Dimensione complessiva Nota
YR:FG22FW 415V/500V/690V 100A 22×58mm Refer to Fig.1 FW: both sides wiring WB: bottom wiring
YR:FG22WB
YR:FG30FW 30×57mm
YR:FG30WB

Selection & Installation Notes

  • Verify system maximum voltage (690VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

FAQ

What voltage and current ratings does the VIOX 690VAC 100A Australia Type Clear HRC Cutout Fuse support?

This VIOX Clear series is rated for 690VAC with a current rating of 100A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX 690VAC 100A Australia Type Clear HRC Cutout Fuse?

The Clear series is designed and verified to BS88 / IEC60269 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX 690VAC 100A Australia Type Clear HRC Cutout Fuse typically installed?

It is engineered for low-voltage hrc industrial fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.