VIOX ELECTRIC
Idioma

VIOX 12kV 15A XRNP Current Limiting Fuse

XRNP VIOX XRNP type high voltage HRC current limiting fuses are designed with insert installation, which is convenient for installation and removal. The 12kV 15A XRNP Current Limiting Fuse is made of high-resistance metal wire and low-resistance metal wire. They are sealed in the.

Série VIOX
XRNP
Tensão nominal
12 kV
Corrente Nominal
15A
Padrão
IEC 60269

Visão geral

XRNP VIOX XRNP type high voltage HRC current limiting fuses are designed with insert installation, which is convenient for installation and removal. The 12kV 15A XRNP Current Limiting Fuse is made of high-resistance metal wire and low-resistance metal wire. They are sealed in the fuse tube filled with chemically treated high-purity quartz sand. The fuse tube is made from heat resistance, high-duty ceramic or epoxy glass. When a fault circuit happens and causes an arc, quartz sand will extinguishes the arc immediately.

Caraterísticas

  • IEC60282-1
  • Elevada capacidade de rutura
  • Good performance and fast action in overload and short circuit protection
  • Comply with international standard size
  • Proteção do transformador
  • Switch Protection
  • Vacuum Contact Protection
  • XRNP Clips

Especificações

XRNP Technical Specifications

Model/Size Rated Voltage (kV) Corrente nominal (A) Rated Drop-Out Current (kA) Dimensão total
L (mm)
XRNP 3.6 0.5, 1, 2, 3.15 ,6.3 50 142
XRNP 7.2 0.5, 1, 2, 3.15 ,6.3 50 142/195
XRNP 12 0.5, 1, 2, 3.15 40 195
XRNP 24 0.5, 1, 2, 3.15 40 355
XRNP 40.5 0.5, 1, 2, 3.15 50 465

Selection & Installation Notes

  • Verify system maximum voltage (12kV) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

FAQ

What voltage and current ratings does the VIOX 12kV 15A XRNP Current Limiting Fuse support?

This VIOX XRNP series is rated for 12kV with a current rating of 15A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX 12kV 15A XRNP Current Limiting Fuse?

The XRNP series is designed and verified to IEC 60269 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX 12kV 15A XRNP Current Limiting Fuse typically installed?

It is engineered for high-voltage current-limiting fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.

Precisa de um orçamento de produto?
Vamos construir juntos.

Envie-nos o modelo do produto, as especificações técnicas, a quantidade e os requisitos de OEM. Nossa equipe analisará sua aplicação e responderá dentro de um dia útil.

Pedir um Orçamento