Industrial Photocell Sensors & Dusk-to-Dawn Switches 24V AC/DC Button Sensors, AS-20 / AS15T Street Light Switches & THC-302–309 Twilight Controls
VIOX Electricは製造しています 9 stocked photocell sensor & twilight switch models—covering true 24V DC solar & 24V AC button sensors, AS-20 / AS15T / CCS-2410E wire-in street light switches, and THC-302 / 303 / 305 / 309 light sensors with 100% dark-chamber Lux calibration.
Browse & Compare All 9 VIOX Photocell Sensor & Twilight Switch Models
Filter our stocked lineup by form factor—24V AC/DC compact button sensors, outdoor wire-in street light switches, and THC-series panel twilight sensors.
AC24V ボタンフォトセルセンサー
24V AC · Compact Button- 電源
- 24V AC (50/60Hz)
- 取り付け
- Fixture / Panel Knockout
- 主な機能
- Built-In Anti-Flicker Delay
- 最適な用途
- Landscape & OEM Fixtures
24V DC Dusk-to-Dawn Photocell
True 24V DC · Solar- 電源
- 24V DC (Battery/Solar)
- 取り付け
- Compact Outdoor DC Body
- 主な機能
- DC Arc-Safe Switching
- 最適な用途
- Solar Street & Signage
AS-20 フォトセル街路灯スイッチ
Flagship · Street Light- 電源
- 120V / 220–240V AC
- 取り付け
- Pole / Wall Bracket (3-Wire)
- 主な機能
- IP65 Rainproof + Delay
- 最適な用途
- Municipal Street & Yards
AS15T Photoelectric Sensor Switch
Wire-In · Compact AC- 電源
- AC Line Voltage
- 取り付け
- Compact Wire-In Outdoor
- 主な機能
- Headlight-Safe Delay
- 最適な用途
- Wall Packs & Walkways
CCS-2410E Photocell Sensor
Wire-In · Weatherproof- 電源
- AC / Low-Voltage Config
- 取り付け
- Weatherproof Wire-In
- 主な機能
- Sealed Optical Window
- 最適な用途
- Exterior & Floodlights
光センサーTHC-302
THC Series · Twilight- 電源
- AC Control Supply
- 取り付け
- THC Series Light Control
- 主な機能
- Calibrated Lux Threshold
- 最適な用途
- Commercial Facades
光センサー THC-303
THC Series · Twilight- 電源
- AC Control Supply
- 取り付け
- THC Series Light Control
- 主な機能
- Anti-Flicker Hysteresis
- 最適な用途
- Stairwells & Billboards
光センサーTHC-305
THC Series · Panel Pilot- 電源
- AC Control Supply
- 取り付け
- THC Series Light Control
- 主な機能
- Contactor Pilot Duty
- 最適な用途
- Multi-Lamp Panel Boards
光センサー THC-309
THC Series · Industrial- 電源
- AC Control Supply
- 取り付け
- THC Series Light Control
- 主な機能
- Heavy-Duty Twilight
- 最適な用途
- Industrial & Municipal
| モデル | Form Factor & Mount | 電源電圧 | 主な用途 | 製品ページ |
|---|---|---|---|---|
| 24V AC Button Photocell | Compact Panel / Fixture Knockout | 24V AC (50/60Hz) | Low-voltage HVAC/landscape lighting & OEM fixture housings | View 24V AC → |
| 24V DC Dusk-to-Dawn | Compact Outdoor DC Sensor | DC24V | Off-grid solar street lights, signage & 24V battery security | View 24V DC → |
| AS-20 Photocell Switch | Outdoor Pole / Wall Bracket (3-Wire) | 120V / 220–240V AC | Municipal street lamps, yard floodlights & parking areas | View AS-20 → |
| AS15T Photoelectric Switch | Compact Wire-In Outdoor Switch | AC Line Voltage | Wall packs, garden walkways, perimeter & sign lighting | View AS15T → |
| CCS-2410E Photocell | Weatherproof Wire-In Sensor | AC / Low-Voltage | Commercial exterior luminaires & security floodlight control | View CCS-2410E → |
| 光センサーTHC-302 | THC Series Light Control | AC Control Supply | Automated dusk-to-dawn commercial & facade lighting | View THC-302 → |
| 光センサー THC-303 | THC Series Light Control | AC Control Supply | Outdoor stairwell, billboard & perimeter lighting circuits | View THC-303 → |
| 光センサーTHC-305 | THC Series Light Control | AC Control Supply | Multi-lamp distribution panel & contactor pilot duty | View THC-305 → |
| 光センサー THC-309 | THC Series Light Control | AC Control Supply | Industrial yard, warehouse perimeter & municipal panels | View THC-309 → |
Match the Right Photocell Sensor & Contactor Pairing to Your Lighting Load
Select your supply voltage, mounting style, and total LED load to avoid relay contact welding and night-time headlight cycling.
Standard 3-Wire Photocell Wiring & Multi-LED Contactor Expansion
Prevent night-time self-cycling and relay contact welding on outdoor LED circuits. Full troubleshooting reference: Complete Guide to Photocell Switches →.
Prevent LED Driver Contact Welding
LED drivers draw 20×–60× capacitive inrush surges at dusk turn-on. For banks above 3 fixtures, use the photocell Red wire to trigger a VIOX モジュラーコンタクタ coil.
Eliminate Night-Time Cycling
Never aim the optical window toward the fixture it controls or reflective white walls. Pair proper orientation with VIOX built-in time delay so car headlights never extinguish street lights.
True 24V DC for Solar Street Lights
AC photocells fail on DC solar batteries due to DC arc persistence and AC-only power stages. Specify VIOX dedicated 24V DC Dusk-to-Dawn Sensor.
VIOX Photocell Sensors vs. Intermatic, Tork, Finder & Steinel
Direct factory alternative for outdoor luminaire OEMs, solar street-light integrators, and electrical distributors.
| Sensor Category | Intermatic / Tork Reference | Finder / Steinel Reference | VIOX Direct Equivalent | 商用・OEM向けの差別化要素 |
|---|---|---|---|---|
| Compact Button Photocell | Intermatic K4321C · Tork 2101 | OEM Fixture Flush Sensor | 24V AC & 24V DC Button Photocell | 45%–65% lower OEM BOM cost; true 24V DC solar option |
| Wire-In Street Light Switch | Intermatic K4121C / EK4036S · Tork 2001 | Steinel NightMatic 2000/3000 | AS-20 · AS15T · CCS-2410E | Custom lead lengths, IP65 potting & private-label boxes |
| Cabinet Twilight Control | Intermatic Panel Controls | Finder 10 / 11 Series Twilight | THC-302 / 303 / 305 / 309 Series | Bundle with VIOX Timer Relays & Modular Contactors |
この点についての率直な見解
If a North American municipal DOT contract strictly specifies ANSI C136.10 twist-lock Intermatic or Tork with zero equivalents allowed, stay with that specified brand. For OEM LED luminaire factories, solar lighting integrators, and regional distributors needing 24V DC + AC wire-in + THC coverage, 45%–65% BOM savings, and custom wire/Lux OEM supply, VIOX is built as your factory partner.
Quotation Variables, 100% Lux Calibration QC & OEM Supply
Transparent factory pricing drivers, dark-chamber Lux verification, LED inrush endurance testing, and OEM luminaire kitting.
| 見積変数 | Standard Baseline | Engineered / OEM Option | Factory Quote Impact |
|---|---|---|---|
| 1. Switching Stage | Standard electromechanical relay (resistive/general) | LED-rated high-inrush relay / zero-crossing electronic switch | Extends switching life under high-inrush LED street drivers |
| 2. Supply Voltage | Single-voltage 220–240V AC or 120V AC | Dedicated 24V DC solar or wide-voltage 105–305V AC | Wide-voltage SMPS consolidates distributor SKUs |
| 3. Weatherproofing & Leads | Standard IP65 housing & 150 mm 18AWG leads | Epoxy-potted PCB, UV-stabilized PC lens, custom 300–500 mm leads | Prevents coastal moisture ingress & speeds fixture assembly |
| 4. OEM Branding & Batch | VIOX standard marking & export box | Custom Lux turn-on setpoint, laser logo, retail blister/color box | Samples 3–5 business days · Batch production 12–20 days |
1. 100% Dark-Chamber Lux QC
Calibrated light chambers verify exact dusk turn-on and dawn turn-off Lux thresholds on every production lot.
2. Anti-Flicker Delay Check
Simulated flash and headlight pulses confirm time-delay stability before housings are sealed.
3. LED Capacitive Inrush Audit
Batch switching endurance under capacitive LED driver loads verifies contact life without welding.
4. IP65 & OEM Luminaire Kitting
Rain-spray ingress checks plus custom wire harnesses and kitting with FCT18 Timers & 接触者.
Generate Your Photocell Sensor RFQ Brief in 30 Seconds
Select target series, supply voltage, load profile, and OEM packaging—copy or attach directly to VIOX engineering.
Photocell Wiring Guides, Astronomical Timers & Contactor Pairing
Engineering references authored by VIOX outdoor lighting and control specialists.
Full Guide to Photocell Switches: Working Principles & Wiring
Complete dusk-to-dawn photocell guide covering Lux thresholds, bypass circuits, and anti-cycling orientation.
Explore Guide →Photocell vs. Astronomical Timer Switch: Stop Lighting Failures
How to eliminate false triggers and choose between ambient Lux sensing and latitude schedules.
Explore Guide →Astronomical Timer vs. Photocell Smart Switch for Commercial Lots
Commercial lighting automation tradeoffs for parking lots, signage, and municipal street feeders.
Explore Guide →Modular Contactors (16A–63A) for High-Inrush LED Lighting Banks
Drive multi-fixture LED banks safely from any photocell Red pilot output without contact welding.
Explore Guide →DIN Rail Timer Relays (FCT18 / THC Astronomical & Digital)
Combine dusk-to-dawn photocell sensing with midnight shutoff or scheduled lighting control.
Explore Guide →Industrial Proximity & Photoelectric Automation Sensors
Inductive, capacitive, and industrial automation sensors for factory machinery and control panels.
Explore Guide →Photocell Sensor Wiring, LED Load & Sourcing Questions
配線 How do you wire a 3-wire dusk-to-dawn photocell sensor to outdoor LED lights?
Connect the Black wire (Line In) to the incoming AC hot/live supply, the White wire (Common Neutral) to both the supply neutral and the luminaire neutral, and the Red wire (Load Out) to the live input of the outdoor light fixture.
For multi-fixture high-inrush LED banks, route the Red output to the coil (A1) of a VIOX Modular Contactor instead of switching the full LED bank directly through the photocell.
トラブルシューティング Why do outdoor photocells sometimes cycle on and off repeatedly at night?
Rapid cycling occurs when light from the controlled fixture reflects directly back onto the photocell lens, fooling it into sensing daylight, or when passing car headlights trigger a unit without a time delay.
Mount the sensor facing away from the luminaire (north-facing in the northern hemisphere) and specify VIOX models with built-in anti-flicker time delay.
セレクション When should I choose a 24V AC/DC button photocell versus an AS-20 or THC-300 series sensor?
Choose 24V AC or 24V DC button photocells for solar street lights, low-voltage landscape systems, and OEM luminaires with compact knockouts.
Use AS-20, AS15T, or CCS-2410E for direct line-voltage (120V/230V AC) pole and wall outdoor fixtures, and THC-302/303/305/309 light sensors for distribution panel twilight control.
LED Inrush Why do LED street light drivers weld cheap photocell contacts shut?
Electronic LED drivers draw high capacitive inrush currents (20×–60× steady-state current) at turn-on. Undersized thermal or low-grade relays weld closed after a few hundred cycles.
Specify VIOX LED-compatible relay/zero-crossing photocells—or let the photocell drive a VIOX Modular Contactor coil when switching multiple LED luminaires.
Cross-Reference Are VIOX photocell sensors compatible with Intermatic K4121C/EK4036S, Tork 2001, and Finder twilight switches?
Yes. VIOX button, wire-in conduit, and THC twilight sensors match standard knockout threads, 3-wire color coding, and Lux turn-on/turn-off thresholds while cutting OEM and distributor BOM cost by 45%–65%.
工場品質管理 What factory QC tests and OEM customizations does VIOX provide for photocell sensors?
Every batch undergoes 100% dark-chamber Lux threshold calibration, anti-headlight delay verification, LED capacitive inrush endurance testing, and IP65 water-ingress checks. OEM options include custom lead wire lengths, custom Lux setpoints, laser/pad logo printing, and private-label retail boxes.
Need 24V Solar, AS-20 Street Light or THC Photocell Samples?
Share your target voltage, Lux threshold, lead length, and LED driver load. VIOX factory sales will reply with sample dispatch details and OEM pricing within 24 hours.