VIOX ELECTRIC
Dil
Direct Factory · Dusk-to-Dawn Photocell Sensor Manufacturer (9 Stocked Models)

Industrial Photocell Sensors & Dusk-to-Dawn Switches 24V AC/DC Button Sensors, AS-20 / AS15T Street Light Switches & THC-302–309 Twilight Controls

VIOX Electric üretmektedir 9 stocked photocell sensor & twilight switch models—covering true 24V DC solar & 24V AC button sensors, AS-20 / AS15T / CCS-2410E wire-in street light switches, and THC-302 / 303 / 305 / 309 light sensors with 100% dark-chamber Lux calibration.

9 ModelsButton · Wire-In · THC Series
24V – 277VTrue 24V DC Solar & AC Grid
100% Lux QCDark-Chamber + Headlight Delay
VIOX AS-20 Dusk-to-Dawn Photocell Street Light Switch
01 · Complete Published Photocell Lineup (9 Models)

Browse & Compare All 9 VIOX Photocell Sensor & Twilight Switch Models

Filter our stocked lineup by form factor—24V AC/DC compact button sensors, outdoor wire-in street light switches, and THC-series panel twilight sensors.

Complete catalog of 9 published VIOX photocell sensors and dusk-to-dawn light switches
Model Form Factor & Mount Besleme Gerilimi Birincil Uygulama Ürün Sayfası
24V AC Button PhotocellCompact Panel / Fixture Knockout24V AC (50/60Hz)Low-voltage HVAC/landscape lighting & OEM fixture housingsView 24V AC →
24V DC Dusk-to-DawnCompact Outdoor DC Sensor24V DCOff-grid solar street lights, signage & 24V battery securityView 24V DC →
AS-20 Photocell SwitchOutdoor Pole / Wall Bracket (3-Wire)120V / 220–240V ACMunicipal street lamps, yard floodlights & parking areasView AS-20 →
AS15T Photoelectric SwitchCompact Wire-In Outdoor SwitchAC Line VoltageWall packs, garden walkways, perimeter & sign lightingView AS15T →
CCS-2410E PhotocellWeatherproof Wire-In SensorAC / Low-VoltageCommercial exterior luminaires & security floodlight controlView CCS-2410E →
Işık Sensörü THC-302THC Series Light ControlAC Control SupplyAutomated dusk-to-dawn commercial & facade lightingView THC-302 →
Işık Sensörü THC-303THC Series Light ControlAC Control SupplyOutdoor stairwell, billboard & perimeter lighting circuitsView THC-303 →
Işık Sensörü THC-305THC Series Light ControlAC Control SupplyMulti-lamp distribution panel & contactor pilot dutyView THC-305 →
Işık Sensörü THC-309THC Series Light ControlAC Control SupplyIndustrial yard, warehouse perimeter & municipal panelsView THC-309 →
02 · Interactive Voltage, Mounting & LED Load Matcher

Match the Right Photocell Sensor & Contactor Pairing to Your Lighting Load

Select your supply voltage, mounting style, and total LED load to avoid relay contact welding and night-time headlight cycling.

1. System Supply Voltage
2. Installation Style
3. Controlled Lighting Load
03 · 3-Wire Wiring Diagram & LED Inrush Protection

Standard 3-Wire Photocell Wiring & Multi-LED Contactor Expansion

Prevent night-time self-cycling and relay contact welding on outdoor LED circuits. Full troubleshooting reference: Complete Guide to Photocell Switches →.

3-WIRE SCHEMATICBlack = Line In · White = Common Neutral · Red = Load Out
Direct Single-Fixture vs. Contactor Pilot Duty
AC / DC Supply L (+) Line In N (−) Neutral VIOX Photocell Sensor AS-20 / AS15T / CCS / 24V Black (L) · White (N) · Red (Load) Built-In Time Delay LED Fixture / Contactor Direct: 1–3 LED Lights Multi-LED: Drive Contactor A1 Zero Contact Welding Risk BLACK (Line) RED (Load Out) WHITE (Shared Neutral Bus — Supply + Sensor + Load)

Prevent LED Driver Contact Welding

LED drivers draw 20×–60× capacitive inrush surges at dusk turn-on. For banks above 3 fixtures, use the photocell Red wire to trigger a VIOX Modüler Kontaktör coil.

Eliminate Night-Time Cycling

Never aim the optical window toward the fixture it controls or reflective white walls. Pair proper orientation with VIOX built-in time delay so car headlights never extinguish street lights.

True 24V DC for Solar Street Lights

AC photocells fail on DC solar batteries due to DC arc persistence and AC-only power stages. Specify VIOX dedicated 24V DC Dusk-to-Dawn Sensor.

04 · Series-Level Cross-Reference Benchmark

VIOX Photocell Sensors vs. Intermatic, Tork, Finder & Steinel

Direct factory alternative for outdoor luminaire OEMs, solar street-light integrators, and electrical distributors.

Comparison of VIOX photocell sensors against Intermatic, Tork, Finder, and Steinel
Sensor Category Intermatic / Tork Reference Finder / Steinel Reference VIOX Direct Equivalent Ticari ve OEM Farkı
Compact Button PhotocellIntermatic K4321C · Tork 2101OEM Fixture Flush Sensor24V AC & 24V DC Button Photocell45%–65% lower OEM BOM cost; true 24V DC solar option
Wire-In Street Light SwitchIntermatic K4121C / EK4036S · Tork 2001Steinel NightMatic 2000/3000AS-20 · AS15T · CCS-2410ECustom lead lengths, IP65 potting & private-label boxes
Cabinet Twilight ControlIntermatic Panel ControlsFinder 10 / 11 Series TwilightTHC-302 / 303 / 305 / 309 SeriesBundle with VIOX Timer Relays & Modular Contactors

Bu Konunun Gerçekçi Değerlendirmesi

If a North American municipal DOT contract strictly specifies ANSI C136.10 twist-lock Intermatic or Tork with zero equivalents allowed, stay with that specified brand. For OEM LED luminaire factories, solar lighting integrators, and regional distributors needing 24V DC + AC wire-in + THC coverage, 45%–65% BOM savings, and custom wire/Lux OEM supply, VIOX is built as your factory partner.

05 · Direct Factory Proof · Photocell Sensor Manufacturer

Quotation Variables, 100% Lux Calibration QC & OEM Supply

Transparent factory pricing drivers, dark-chamber Lux verification, LED inrush endurance testing, and OEM luminaire kitting.

4 specification and OEM variables that determine VIOX photocell sensor factory unit pricing
Teklif Değişkeni Standard Baseline Engineered / OEM Option Factory Quote Impact
1. Switching StageStandard electromechanical relay (resistive/general)LED-rated high-inrush relay / zero-crossing electronic switchExtends switching life under high-inrush LED street drivers
2. Supply VoltageSingle-voltage 220–240V AC or 120V ACDedicated 24V DC solar or wide-voltage 105–305V ACWide-voltage SMPS consolidates distributor SKUs
3. Weatherproofing & LeadsStandard IP65 housing & 150 mm 18AWG leadsEpoxy-potted PCB, UV-stabilized PC lens, custom 300–500 mm leadsPrevents coastal moisture ingress & speeds fixture assembly
4. OEM Branding & BatchVIOX standard marking & export boxCustom Lux turn-on setpoint, laser logo, retail blister/color boxSamples 3–5 business days · Batch production 12–20 days

1. 100% Dark-Chamber Lux QC

Calibrated light chambers verify exact dusk turn-on and dawn turn-off Lux thresholds on every production lot.

2. Anti-Flicker Delay Check

Simulated flash and headlight pulses confirm time-delay stability before housings are sealed.

3. LED Capacitive Inrush Audit

Batch switching endurance under capacitive LED driver loads verifies contact life without welding.

4. IP65 & OEM Luminaire Kitting

Rain-spray ingress checks plus custom wire harnesses and kitting with FCT18 Timers ve Kontaktörler.

Evaluation Samples2–5 pcs/model dispatched in 3–5 business days for Lux calibration & fixture-fit tests.
Mixed-Model MOQMix 24V, AS-20 & THC models from $1,500–$2,000 · Production 12–20 days.
Export & WarrantyEXW / FOB Ningbo or Shanghai · 2–3 year factory replacement warranty.
06 · Interactive B2B Tool · 5-Step Photocell Sensor RFQ Builder

Generate Your Photocell Sensor RFQ Brief in 30 Seconds

Select target series, supply voltage, load profile, and OEM packaging—copy or attach directly to VIOX engineering.

1. Target VIOX Model / Style
2. Supply Voltage
3. Controlled Load Type
4. Wire & Lux Customization
5. Supply Mode
07 · Lighting Control Knowledge & Companion Hubs

Photocell Wiring Guides, Astronomical Timers & Contactor Pairing

Engineering references authored by VIOX outdoor lighting and control specialists.

08 · Technical & Wiring FAQ

Photocell Sensor Wiring, LED Load & Sourcing Questions

Kablolama How do you wire a 3-wire dusk-to-dawn photocell sensor to outdoor LED lights?

Connect the Black wire (Line In) to the incoming AC hot/live supply, the White wire (Common Neutral) to both the supply neutral and the luminaire neutral, and the Red wire (Load Out) to the live input of the outdoor light fixture.

For multi-fixture high-inrush LED banks, route the Red output to the coil (A1) of a VIOX Modular Contactor instead of switching the full LED bank directly through the photocell.

Sorun giderme Why do outdoor photocells sometimes cycle on and off repeatedly at night?

Rapid cycling occurs when light from the controlled fixture reflects directly back onto the photocell lens, fooling it into sensing daylight, or when passing car headlights trigger a unit without a time delay.

Mount the sensor facing away from the luminaire (north-facing in the northern hemisphere) and specify VIOX models with built-in anti-flicker time delay.

Seçim When should I choose a 24V AC/DC button photocell versus an AS-20 or THC-300 series sensor?

Choose 24V AC or 24V DC button photocells for solar street lights, low-voltage landscape systems, and OEM luminaires with compact knockouts.

Use AS-20, AS15T, or CCS-2410E for direct line-voltage (120V/230V AC) pole and wall outdoor fixtures, and THC-302/303/305/309 light sensors for distribution panel twilight control.

LED Inrush Why do LED street light drivers weld cheap photocell contacts shut?

Electronic LED drivers draw high capacitive inrush currents (20×–60× steady-state current) at turn-on. Undersized thermal or low-grade relays weld closed after a few hundred cycles.

Specify VIOX LED-compatible relay/zero-crossing photocells—or let the photocell drive a VIOX Modular Contactor coil when switching multiple LED luminaires.

Cross-Reference Are VIOX photocell sensors compatible with Intermatic K4121C/EK4036S, Tork 2001, and Finder twilight switches?

Yes. VIOX button, wire-in conduit, and THC twilight sensors match standard knockout threads, 3-wire color coding, and Lux turn-on/turn-off thresholds while cutting OEM and distributor BOM cost by 45%–65%.

Fabrika Kalite Kontrolü What factory QC tests and OEM customizations does VIOX provide for photocell sensors?

Every batch undergoes 100% dark-chamber Lux threshold calibration, anti-headlight delay verification, LED capacitive inrush endurance testing, and IP65 water-ingress checks. OEM options include custom lead wire lengths, custom Lux setpoints, laser/pad logo printing, and private-label retail boxes.

Direct Engineering & OEM Luminaire Support

Need 24V Solar, AS-20 Street Light or THC Photocell Samples?

Share your target voltage, Lux threshold, lead length, and LED driver load. VIOX factory sales will reply with sample dispatch details and OEM pricing within 24 hours.

9 Stocked Button, Wire-In & THC Models 100% Dark-Chamber Lux Calibration Custom Lead Lengths & OEM Packaging