Industrial Monitoring, Voltage, Current & Floatless Level Relays 3-Phase & AC/DC Voltage Monitors (FCP18 / FCV18 / FCC18 / FCB18), Conductive Floatless Relays (61F-G / AFR-1 / FCL18) & YX Step/WiFi Control
VIOXは製造しています 15 industrial monitoring and control relays: 3-phase & AC/DC voltage monitors (FCP18, FCV18), current & twilight relays (FCC18, FCB18), conductive-probe floatless level relays (61F-G, AFR-1, FCL18), and YX step/WiFi relays.
What Are Industrial Monitoring & Floatless Relays?
Industrial monitoring and floatless relays continuously supervise three-phase or AC/DC voltage, phase sequence, load current, ambient light, and conductive liquid levels without mechanical floats, switching control contacts before faults damage motors or pumps. Paired with modular step/impulse and WiFi relays, they form the panel control layer—while pure time-delay sequences live in our Timer Relay Hub.
- Voltage & Phase: 3-phase sequence/loss & AC/DC window (
FCP18,FCV18). - Current & Lux: Load jam/dry-run (
FCC18) & dusk-to-dawn (FCB18). - Floatless Level: Conductive probes, zero floats (
61F-G,AFR-1,FCL18). - Step & WiFi: Push-button impulse, call/reset & smart switching (
YX).
Complete VIOX Monitoring & Control Relay Catalog
Filter all 15 stocked VIOX relays across three dedicated groups—Voltage/Phase/Current Monitoring (4), Floatless Liquid Level Control (5), and Step/Impulse/WiFi Relays (6)—or use the interactive selector below to pinpoint your exact model.
VIOX FCP18 三相電圧リレー
FCP18 · 3-Phase Voltage- 機能
- Over/Under V + Phase Loss
- 電源
- 3×220V–480V AC
- 取り付け
- 18mm DIN Rail (1-Mod)
- 出力
- 1SPDT / 2SPDT Relay
VIOX FCV18-01/02 単相電圧リレー
FCV18 · 1-Phase Voltage- 機能
- AC/DC Over & Under Voltage
- 電源
- AC/DC 12V–240V Opt.
- 取り付け
- 18mm DIN Rail (1-Mod)
- 出力
- 1SPDT · Adj. Delay
VIOX FCC18-01/2/3/4 単相電流リレー
FCC18 · Current Monitor- 機能
- Over/Under Current Load
- 電源
- AC 24V–240V / DC 24V
- 取り付け
- 18mm DIN Rail (1-Mod)
- 出力
- 0.1A–16A Direct / CT
VIOX FCB18 トワイライトリレー
FCB18 · Twilight / Lux- 機能
- Ambient Lux Light Level
- 電源
- AC/DC 12V–240V
- 取り付け
- 18mm DIN + IP65 Sensor
- 出力
- 1–50,000 Lux Adj.
61F-G フロートレスリレー
61F-G · Floatless Level- 機能
- Conductive Probe Supply/Drain
- 電源
- 110V / 220V / 380V AC
- 取り付け
- Base / Panel Socket
- 出力
- 8V AC Safe Electrode
61F-G1 Floatless Relay
61F-G1 · Dry-Run Guard- 機能
- Auto Supply + Dry-Run Alarm
- 電源
- 110V / 220V / 380V AC
- 取り付け
- Base / Panel Socket
- 出力
- 2-Relay Dual Output
AFR-1 Floatless Relay
AFR-1 · 8-Pin Plug-In- 機能
- Compact Conductive Probe
- 電源
- 110V / 220V AC
- 取り付け
- 8-Pin PF083A Socket
- 出力
- 1SPDT · Water Tanks
PM61F-GR Floatless Relay
PM61F-GR · 11-Pin Base- 機能
- High-Sensitivity Level Ctrl
- 電源
- 110V / 220V AC
- 取り付け
- 11-Pin Plug-In Base
- 出力
- LED Status · Pump Ctrl
VIOX FCL18-01/02 液面制御リレー
FCL18 · 18mm DIN Level- 機能
- 5–100 kΩ Adjustable Probe
- 電源
- AC/DC 24V–240V
- 取り付け
- 18mm DIN Rail (1-Mod)
- 出力
- Pump-Up / Pump-Down
VIOX ステップリレー YX2210/YX2220
YX2210/2220 · Step Relay- 機能
- Push-Button Impulse Latch
- 電源
- 230V AC / 24V AC-DC
- 取り付け
- 18mm DIN Rail Modular
- 出力
- 16A 1NO / 2NO Latching
VIOX ステップ単安定リレー YX2110
YX2110 · Monostable- 機能
- Pulse-Triggered Monostable
- 電源
- 230V AC / 24V Opt.
- 取り付け
- 18mm DIN Rail Modular
- 出力
- 16A Control Switching
VIOX Modular Step Relay YX2221
YX2221 · Modular Step- 機能
- Multi-Point Lighting Control
- 電源
- 230V AC Control Coil
- 取り付け
- 18mm DIN Rail Modular
- 出力
- 1NO + 1NC Latching
VIOXコールリセットリレー YX2010
YX2010 · Call / Reset- 機能
- Set / Reset Alarm Latch
- 電源
- 230V AC / 24V Opt.
- 取り付け
- 18mm DIN Rail Modular
- 出力
- Nurse-Call & Interlock
VIOX WiFi インテリジェントリレー YX1010
YX1010 · WiFi Smart- 機能
- App Remote + Schedule
- 電源
- AC 230V · 2.4GHz WiFi
- 取り付け
- 18mm DIN Rail Smart
- 出力
- 16A Dry/Load Control
VIOX WiFi インテリジェントリレー YX1011
YX1011 · WiFi Dual- 機能
- Cloud / App Automation
- 電源
- AC 230V · 2.4GHz WiFi
- 取り付け
- 18mm DIN Rail Smart
- 出力
- Remote Panel Switching
Voltage, Current & Liquid Level Relay Selection Matrix
Compare sensing parameters, supply voltages, adjustment ranges, and mounting footprints across all three VIOX monitoring and control relay families.
| Relay Family | VIOX Models | Monitored / Control Input | 電源電圧 | Mounting & Width | Primary Protection / Control Role |
|---|---|---|---|---|---|
| 3-Phase Voltage & Phase Sequence | FCP18 |
Over/Under V, phase loss, phase reversal, asymmetry | 3×220V–480V AC (380V std) | 18 mm DIN Rail (1-Module) | Chillers, elevators, 3-phase pumps, compressors, HVAC |
| Single-Phase & DC Voltage | FCV18-01/02 |
Single-phase AC/DC over & under voltage window | AC/DC 12V–240V Options | 18 mm DIN Rail (1-Module) | DC battery banks, solar DC buses, gensets, commercial mains |
| Current & Twilight Sensing | FCC18 · FCB18 |
0.1A–16A AC/DC current (or CT) · 1–50,000 lux light | 24V–240V AC/DC | 18 mm DIN (+ external IP65 photocell on FCB18) | Dry-run pump detection, conveyor jam alarm, street lighting |
| Floatless Liquid Level | 61F-G · 61F-G1 · AFR-1 · PM61F-GR · FCL18 |
Conductive probe resistance (0–4 kΩ / 5–100 kΩ) | 110V / 220V / 380V AC · 24–240V AC/DC | Base / 8-Pin / 11-Pin Socket & 18 mm DIN | Overhead tanks, deep wells, sewage sumps, dry-run prevention |
| Step, Impulse & WiFi Control | YX2210/2220 · YX2110 · YX2221 · YX2010 · YX1010/1011 |
Momentary push-button pulse, set/reset, 2.4 GHz WiFi | 230V AC / 24V AC-DC | 18 mm DIN Rail Modular (16A) | Staircase/hallway lighting, call-reset interlocks, smart panels |
Floatless Level Relay vs Mechanical Float Switch
Why industrial pump stations, municipal water towers, and borehole panels standardize on floatless relays (61F-G, 61F-G1, AFR-1, PM61F-GR, FCL18) instead of suspended mechanical float balls.
Unlike suspended mechanical float balls that tangle, jam in grease, or crack in narrow boreholes, a floatless relay (61F-G, 61F-G1, AFR-1, PM61F-GR, FCL18) uses three rigid stainless-steel electrodes (E1 High, E2 Low, E3 Common) driven by an isolated 8V AC signal—preventing electrolysis corrosion and eliminating all moving parts inside the tank.
| Selection Factor | DIN-Rail Modular Series (FCP18 / FCV18 / FCC18 / FCL18) | Base / Plug-In Socket Series (61F-G / 61F-G1 / AFR-1 / PM61F-GR) |
|---|---|---|
| Panel Footprint & Mounting | Ultra-slim 18 mm (1-module) snap-on 35 mm TS35 DIN rail | Panel-mount base (61F-G/G1) or 8-pin / 11-pin plug-in socket (AFR-1 / PM61F-GR) |
| Supply Voltage Flexibility | Wide-range universal AC/DC 24V–240V (or 3×220–480V AC on FCP18) | Dedicated industrial transformer coil (110V / 220V / 380V AC) |
| Probe Sensitivity Tuning | Front rotary dial 5 kΩ – 100 kΩ (FCL18 adapts to low-conductivity water) | Fixed factory threshold (~0–4 kΩ) optimized for municipal, well & industrial water |
| Maintenance & Replacement | Tool-free DIN clip replacement inside modern IEC distribution boards | Hot-swap plug-in replacement in legacy pump panels without rewiring the socket |
| Best-Fit Applications | New OEM switchboards, compact control cabinets, multi-parameter DIN assemblies | Water pump stations, booster sets, deep-well borehole panels, 61F-G drop-in retrofits |
Monitoring Relays vs Timer Relays vs Thermal Overload Relays
Each relay family handles a distinct protection or automation layer inside a motor control center. Use this matrix to coordinate your panel BOM without functional gaps or overlap.
| 比較項目 | Monitoring & Floatless Relays (This Hub) | Industrial Timer Relays → | 熱動過負荷リレー → |
|---|---|---|---|
| Primary Trigger Signal | Voltage window, phase loss/sequence, load current, lux, or conductive liquid level | Elapsed time sequence (ON-delay, OFF-delay, star-delta, cycle, pulse) | Sustained motor overcurrent heating (inverse-time I²t bimetallic curve) |
| Typical Faults Prevented | Phase reversal, brownout, DC over-discharge, tank overflow, pump dry-run | Simultaneous startup inrush, star-delta shorting, process timing drift | Locked rotor, mechanical overload, prolonged single-phasing winding burnout |
| Panel Wiring Position | Control circuit coil interlock (drives contactor coil A1/A2) | Control circuit sequencing logic (between PLC/push-button and contactor) | Power circuit directly below AC contactor (T1/T2/T3) + 95–96 NC trip contact |
| Representative VIOX Series | FCP18, FCV18, FCC18, FCB18, 61F-G, AFR-1, FCL18, YX |
Browse VIOX Timer Relays → | Browse LRD / JR28 / JR36 Overload Relays → |
Typical Panel Applications
How panel builders, pump OEMs, and facility engineers deploy VIOX monitoring, floatless level, and step control relays across three high-demand industrial environments.
Water Supply, Booster & Sump Drainage Panels
Automate overhead tank filling and sump drainage with 61F-G1 または FCL18 conductive probes plus FCC18 dry-run shutdown.
Three-Phase Phase-Loss & Sequence Protection
Protect chillers, elevators, and compressors against phase reversal and single-phasing with FCP18 + サーマルオーバーロードリレー.
Multi-Point Step Lighting & Smart Panels
Switch multi-point corridor lighting with YX2210/YX2221 step relays, dusk-to-dawn loads with FCB18, or app schedules with YX1010/YX1011.
What Is a Floatless Relay? Electrode Wiring & Pump Control Guide
How 61F-G, 61F-G1, AFR-1, and FCL18 conductive-probe relays automate water tanks without moving floats.
Explore Guide →Voltage Monitoring Relay: Working Principle, Wiring & Settings
Configure over-voltage, under-voltage, hysteresis, and trip delay thresholds across AC and DC panels.
Explore Guide →Three-Phase Voltage Monitoring Relay Functions: VIOX FCP18 Guide
Prevent motor burnout from phase loss, phase reversal, and asymmetry on 380V–480V industrial feeders.
Explore Guide →Current Monitoring Relay: Working Principle & Load Settings
Detect pump dry-running, jammed conveyors, and broken belts using FCC18 under/over-current windows.
Explore Guide →Industrial Timer Relays (Delay, Cycle, Star-Delta & Pulse)
Need pure time-delay sequences rather than voltage, current, or level sensing? Visit our Timer Relay hub.
Explore Guide →Thermal Overload Relays (LRD / JR28 / JR36 Motor Protection)
Pair voltage and phase-sequence monitoring with Class 10A/20 thermal overload relays for full motor safety.
Explore Guide →Monitoring & Floatless Relay Selection FAQ
Floatless Level How does a floatless relay detect water level without a mechanical float switch?
A floatless relay (61F-G, AFR-1, PM61F-GR, or FCL18) sends a safe 8V AC signal across stainless-steel electrodes (E1 high, E2 low, E3 common). Conductive water bridges the probes to switch the pump relay—eliminating jammed floats and tangled cables.
AC/DC Voltage Which VIOX relay supports DC voltage monitoring for battery banks and solar panels?
Choose VIOX FCV18-01/02 (18 mm DIN-rail AC/DC voltage monitoring relay, 12V–240V AC/DC options with adjustable hysteresis and trip delay) to protect DC battery banks, telecom rectifiers, and solar DC control buses.
3-Phase Motor How does the FCP18 three-phase voltage monitoring relay protect industrial motors?
VIOX FCP18 (18 mm DIN rail) supervises 3×220V–480V AC lines for over/under-voltage, phase loss, and phase reversal—dropping out the contactor coil before reverse rotation or single-phasing damages motors.
DIN vs. Socket What is the difference between DIN-rail FCL18 and socket-mount 61F-G / AFR-1 floatless relays?
DIN-rail FCL18 (18 mm) accepts 24V–240V AC/DC and offers 5–100 kΩ sensitivity tuning. Socket-mount 61F-G, 61F-G1 (with dry-run alarm), AFR-1 (8-pin), and PM61F-GR (11-pin) are drop-in replacements for industrial pump panels.
Boundary & Delay Does a monitoring relay replace a timer relay or a thermal overload relay?
No. Monitoring relays sense voltage, current, or liquid level. For dedicated delay, cycle, or star-delta timing, use VIOX Timer Relays (/timer-relay/); for I²t motor overload protection, pair with VIOX Thermal Overload Relays (/overload-relay/).
Need FC18 Monitoring Relays, 61F-G / FCL18 Floatless Relays or YX Step Relays?
Send your supply voltage, monitored parameter, mounting format (18 mm DIN or 8/11-pin socket), and project quantity. VIOX engineers respond within 24 hours with datasheets, wiring diagrams, and OEM pricing.