VIOX ELECTRIC
Sprache
Direct Factory · Voltage, Current, Floatless Level & Step Control Relays (15 Models)

Industrial Monitoring, Voltage, Current & Floatless Level Relays 3-Phase & AC/DC Voltage Monitors (FCP18 / FCV18 / FCC18 / FCB18), Conductive Floatless Relays (61F-G / AFR-1 / FCL18) & YX Step/WiFi Control

VIOX fertigt 15 industrial monitoring and control relays: 3-phase & AC/DC voltage monitors (FCP18, FCV18), current & twilight relays (FCC18, FCB18), conductive-probe floatless level relays (61F-G, AFR-1, FCL18), and YX step/WiFi relays.

15 Stocked Models3 Monitoring & Control Families
AC/DC 12V–480VVoltage · Phase · Current
8V AC Safe Probes61F-G · AFR-1 · FCL18 Level
VIOX FCP18 three-phase voltage monitoring relay and industrial floatless level relays
01 · Core Definition & Engineering Scope

What Are Industrial Monitoring & Floatless Relays?

Industrial monitoring and floatless relays continuously supervise three-phase or AC/DC voltage, phase sequence, load current, ambient light, and conductive liquid levels without mechanical floats, switching control contacts before faults damage motors or pumps. Paired with modular step/impulse and WiFi relays, they form the panel control layer—while pure time-delay sequences live in our Timer Relay Hub.

  • Voltage & Phase: 3-phase sequence/loss & AC/DC window (FCP18, FCV18).
  • Current & Lux: Load jam/dry-run (FCC18) & dusk-to-dawn (FCB18).
  • Floatless Level: Conductive probes, zero floats (61F-G, AFR-1, FCL18).
  • Step & WiFi: Push-button impulse, call/reset & smart switching (YX).
02 · Complete 15-Model Catalog & Interactive Selector

Complete VIOX Monitoring & Control Relay Catalog

Filter all 15 stocked VIOX relays across three dedicated groups—Voltage/Phase/Current Monitoring (4), Floatless Liquid Level Control (5), and Step/Impulse/WiFi Relays (6)—or use the interactive selector below to pinpoint your exact model.

1. Primary Monitoring or Control Function
2. Preferred Panel Mounting Style
03 · Engineering Specification Quick-Reference

Voltage, Current & Liquid Level Relay Selection Matrix

Compare sensing parameters, supply voltages, adjustment ranges, and mounting footprints across all three VIOX monitoring and control relay families.

Table 1: VIOX 3-Family Monitoring, Floatless Level & Control Relay Specification Matrix
Relay Family VIOX Models Monitored / Control Input Versorgungsspannung Mounting & Width Primary Protection / Control Role
3-Phase Voltage & Phase Sequence FCP18 Over/Under V, phase loss, phase reversal, asymmetry 3×220V–480V AC (380V std) 18 mm DIN Rail (1-Module) Chillers, elevators, 3-phase pumps, compressors, HVAC
Single-Phase & DC Voltage FCV18-01/02 Single-phase AC/DC over & under voltage window AC/DC 12V–240V Options 18 mm DIN Rail (1-Module) DC battery banks, solar DC buses, gensets, commercial mains
Current & Twilight Sensing FCC18 · FCB18 0.1A–16A AC/DC current (or CT) · 1–50,000 lux light 24V–240V AC/DC 18 mm DIN (+ external IP65 photocell on FCB18) Dry-run pump detection, conveyor jam alarm, street lighting
Floatless Liquid Level 61F-G · 61F-G1 · AFR-1 · PM61F-GR · FCL18 Conductive probe resistance (0–4 kΩ / 5–100 kΩ) 110V / 220V / 380V AC · 24–240V AC/DC Base / 8-Pin / 11-Pin Socket & 18 mm DIN Overhead tanks, deep wells, sewage sumps, dry-run prevention
Step, Impulse & WiFi Control YX2210/2220 · YX2110 · YX2221 · YX2010 · YX1010/1011 Momentary push-button pulse, set/reset, 2.4 GHz WiFi 230V AC / 24V AC-DC 18 mm DIN Rail Modular (16A) Staircase/hallway lighting, call-reset interlocks, smart panels
04 · Conductive-Probe Level Control Engineering

Floatless Level Relay vs Mechanical Float Switch

Why industrial pump stations, municipal water towers, and borehole panels standardize on floatless relays (61F-G, 61F-G1, AFR-1, PM61F-GR, FCL18) instead of suspended mechanical float balls.

Unlike suspended mechanical float balls that tangle, jam in grease, or crack in narrow boreholes, a floatless relay (61F-G, 61F-G1, AFR-1, PM61F-GR, FCL18) uses three rigid stainless-steel electrodes (E1 High, E2 Low, E3 Common) driven by an isolated 8V AC signal—preventing electrolysis corrosion and eliminating all moving parts inside the tank.

Table 2: DIN-Rail Modular Relays (FCP18 / FCV18 / FCC18 / FCL18) vs. Socket / Base Floatless Relays (61F-G / 61F-G1 / AFR-1 / PM61F-GR)
Auswahlfaktor DIN-Rail Modular Series (FCP18 / FCV18 / FCC18 / FCL18) Base / Plug-In Socket Series (61F-G / 61F-G1 / AFR-1 / PM61F-GR)
Panel Footprint & Mounting Ultra-slim 18 mm (1-module) snap-on 35 mm TS35 DIN rail Panel-mount base (61F-G/G1) or 8-pin / 11-pin plug-in socket (AFR-1 / PM61F-GR)
Supply Voltage Flexibility Wide-range universal AC/DC 24V–240V (or 3×220–480V AC on FCP18) Dedicated industrial transformer coil (110V / 220V / 380V AC)
Probe Sensitivity Tuning Front rotary dial 5 kΩ – 100 kΩ (FCL18 adapts to low-conductivity water) Fixed factory threshold (~0–4 kΩ) optimized for municipal, well & industrial water
Maintenance & Replacement Tool-free DIN clip replacement inside modern IEC distribution boards Hot-swap plug-in replacement in legacy pump panels without rewiring the socket
Best-Fit Applications New OEM switchboards, compact control cabinets, multi-parameter DIN assemblies Water pump stations, booster sets, deep-well borehole panels, 61F-G drop-in retrofits
05 · Relay Architecture & Sister Hub Coordination

Monitoring Relays vs Timer Relays vs Thermal Overload Relays

Each relay family handles a distinct protection or automation layer inside a motor control center. Use this matrix to coordinate your panel BOM without functional gaps or overlap.

Table 3: Functional Boundary Matrix — Monitoring Relays vs. Timer Relays vs. Thermal Overload Relays
Vergleichskriterium Monitoring & Floatless Relays (This Hub) Industrial Timer Relays → Thermal Overload Relays →
Primary Trigger Signal Voltage window, phase loss/sequence, load current, lux, or conductive liquid level Elapsed time sequence (ON-delay, OFF-delay, star-delta, cycle, pulse) Sustained motor overcurrent heating (inverse-time I²t bimetallic curve)
Typical Faults Prevented Phase reversal, brownout, DC over-discharge, tank overflow, pump dry-run Simultaneous startup inrush, star-delta shorting, process timing drift Locked rotor, mechanical overload, prolonged single-phasing winding burnout
Panel Wiring Position Control circuit coil interlock (drives contactor coil A1/A2) Control circuit sequencing logic (between PLC/push-button and contactor) Power circuit directly below AC contactor (T1/T2/T3) + 95–96 NC trip contact
Representative VIOX Series FCP18, FCV18, FCC18, FCB18, 61F-G, AFR-1, FCL18, YX Browse VIOX Timer Relays → Browse LRD / JR28 / JR36 Overload Relays →
06 · Real-World Panel Deployments & Technical Guides

Typical Panel Applications

How panel builders, pump OEMs, and facility engineers deploy VIOX monitoring, floatless level, and step control relays across three high-demand industrial environments.

Application 01 · Pump Rooms

Water Supply, Booster & Sump Drainage Panels

Automate overhead tank filling and sump drainage with 61F-G1 oder FCL18 conductive probes plus FCC18 dry-run shutdown.

Application 02 · 3-Phase Motors

Three-Phase Phase-Loss & Sequence Protection

Protect chillers, elevators, and compressors against phase reversal and single-phasing with FCP18 + Thermische Überlastrelais.

Application 03 · Building Control

Multi-Point Step Lighting & Smart Panels

Switch multi-point corridor lighting with YX2210/YX2221 step relays, dusk-to-dawn loads with FCB18, or app schedules with YX1010/YX1011.

Factory Samples2–10 pcs sample kits ship in 3–5 business days across FC18, 61F, AFR-1 & YX series.
OEM & Private LabelCustom voltage windows, 8/11-pin sockets & laser branding from $1,500 MOQ.
100% Trip Calibration100% threshold calibration & dielectric hi-pot tested before shipment.
07 · Frequently Asked Questions

Monitoring & Floatless Relay Selection FAQ

Floatless Level How does a floatless relay detect water level without a mechanical float switch?

A floatless relay (61F-G, AFR-1, PM61F-GR, or FCL18) sends a safe 8V AC signal across stainless-steel electrodes (E1 high, E2 low, E3 common). Conductive water bridges the probes to switch the pump relay—eliminating jammed floats and tangled cables.

AC/DC Voltage Which VIOX relay supports DC voltage monitoring for battery banks and solar panels?

Choose VIOX FCV18-01/02 (18 mm DIN-rail AC/DC voltage monitoring relay, 12V–240V AC/DC options with adjustable hysteresis and trip delay) to protect DC battery banks, telecom rectifiers, and solar DC control buses.

3-Phase Motor How does the FCP18 three-phase voltage monitoring relay protect industrial motors?

VIOX FCP18 (18 mm DIN rail) supervises 3×220V–480V AC lines for over/under-voltage, phase loss, and phase reversal—dropping out the contactor coil before reverse rotation or single-phasing damages motors.

DIN vs. Socket What is the difference between DIN-rail FCL18 and socket-mount 61F-G / AFR-1 floatless relays?

DIN-rail FCL18 (18 mm) accepts 24V–240V AC/DC and offers 5–100 kΩ sensitivity tuning. Socket-mount 61F-G, 61F-G1 (with dry-run alarm), AFR-1 (8-pin), and PM61F-GR (11-pin) are drop-in replacements for industrial pump panels.

Boundary & Delay Does a monitoring relay replace a timer relay or a thermal overload relay?

No. Monitoring relays sense voltage, current, or liquid level. For dedicated delay, cycle, or star-delta timing, use VIOX Timer Relays (/timer-relay/); for I²t motor overload protection, pair with VIOX Thermal Overload Relays (/overload-relay/).

Direct Factory Monitoring & Floatless Relay Supply

Need FC18 Monitoring Relays, 61F-G / FCL18 Floatless Relays or YX Step Relays?

Send your supply voltage, monitored parameter, mounting format (18 mm DIN or 8/11-pin socket), and project quantity. VIOX engineers respond within 24 hours with datasheets, wiring diagrams, and OEM pricing.

15 Stocked Industrial ModelsAC/DC Voltage · Current · Floatless LevelZero Overlap with Timer Relays