VIOX Electric
Language

Busbar Insulator Manufacturer (SM, DMC/BMC, SMC & Cast Epoxy · 660 V–36 kV)

Factory-direct UL94 V-0 molded DMC, BMC, and SMC stand-off insulators (SM, SEP, TSM, MNS, C, D, 71), stepped & clamp busbar supports (CT, REL, HL, DL, EL), and cast epoxy high-voltage insulators across 22 published series plus custom CAD molds.

22 Published Series15 LV Stand-Offs · 5 Clamps · 2 HV Epoxy
660 V – 36 kVUL94 V-0 DMC/BMC/SMC & Cast Epoxy
M6 – M12 & ImperialSteel, Brass & SS304/316 Inserts
VIOX busbar support insulators including SM stand-offs, stepped CT supports, and epoxy insulators

VIOX Busbar Support Insulator Catalog

A busbar insulator performs two critical jobs simultaneously: electrically isolating live copper or aluminum busbars from grounded enclosures, and mechanically bracing bars against short-circuit electrodynamic forces.

SM Series Busbar Insulator
Core Hex Stand-Off

SM Series

SM Series Busbar Insulator

Voltage Class
660 V – 1500 V AC/DC
Material
UL94 V-0 DMC / BMC
Thread / Mount
M6 – M12 / Imperial
Primary Use
General LV switchboards & DBs
SM-B Series Busbar Insulator
Reinforced Stand-Off

SM-B Series

SM-B Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
UL94 V-0 DMC / BMC
Thread / Mount
M6 – M10 Inserts
Primary Use
Compact panel busbar mounting
SEP Series Busbar Insulator
Precision Stand-Off

SEP Series

SEP Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
UL94 V-0 DMC / SMC
Thread / Mount
M6 – M12 Inserts
Primary Use
Distribution panels & OEM cabinets
TSM Series Busbar Insulator
Flanged Stand-Off

TSM Series

TSM Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
UL94 V-0 DMC / BMC
Thread / Mount
M6 – M10 Inserts
Primary Use
High-stability base mounting
EN Series Busbar Insulator
Switchgear Stand-Off

EN Series

EN Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
High-Strength SMC
Thread / Mount
M8 – M12 Inserts
Primary Use
Industrial MCC & switchgear
SE Busbar Insulator
Cylindrical Stand-Off

SE Series

SE Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
UL94 V-0 DMC / BMC
Thread / Mount
M6 – M10 Inserts
Primary Use
Control cabinets & inverters
C Series Busbar Insulator
Heavy Switchgear

C Series

C Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
High-Strength SMC
Thread / Mount
M8 – M12 Inserts
Primary Use
High-fault LV main busbars
MNS Series Busbar Insulator
MNS Switchgear

MNS Series

MNS Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
Glass-Filled SMC
Thread / Mount
MNS Modular Pitch
Primary Use
MNS withdrawable switchgear
SB Series Busbar Insulator
Heavy-Duty Post

SB Series

SB Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
High-Strength SMC
Thread / Mount
M8 – M12 Inserts
Primary Use
High-cantilever busbar spans
D Series Busbar Insulator
Panel Stand-Off

D Series

D Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
UL94 V-0 DMC / SMC
Thread / Mount
M6 – M10 Inserts
Primary Use
Commercial distribution boards
71 Series Busbar Insulator
Compact Spacer

71 Series

71 Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
UL94 V-0 SMC / BMC
Thread / Mount
M6 – M10 Inserts
Primary Use
Tight-clearance panel assemblies
S Series Busbar Insulator
Ribbed Stand-Off

S Series

S Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
UL94 V-0 DMC / BMC
Thread / Mount
M6 – M10 Inserts
Primary Use
Extended creepage LV panels
JYZ Series Busbar Insulator
Cylindrical Post

JYZ Series

JYZ Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
UL94 V-0 DMC / BMC
Thread / Mount
M6 – M12 Inserts
Primary Use
Power distribution & UPS racks
P Series Busbar Insulator
Flat-Base Support

P Series

P Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
UL94 V-0 DMC / BMC
Thread / Mount
M6 – M10 Inserts
Primary Use
Low-profile busbar isolation
T Series Busbar Insulator
Tapered Stand-Off

T Series

T Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
UL94 V-0 DMC / BMC
Thread / Mount
M6 – M12 Inserts
Primary Use
General switchgear & bus ducts
CT Series Stepped Busbar Insulator
Stepped Multi-Phase

CT Stepped

CT Series Stepped Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
UL94 V-0 DMC / SMC
Thread / Mount
3P / 4P Staggered
Primary Use
Compact staggered 3P/4P busbars
REL Series Busbar Insulator
Multi-Bar Support

REL Series

REL Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
Glass-Filled SMC
Thread / Mount
Multi-Bar Clamp
Primary Use
High-current laminated busbars
HL Series Busbar Insulator
Clamp Support

HL Series

HL Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
High-Strength SMC
Thread / Mount
Through-Bolt Clamp
Primary Use
Heavy distribution switchgear
DL Series Busbar Insulator
Rail Busbar Clamp

DL Series

DL Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
High-Strength SMC
Thread / Mount
Multi-Phase Clamp
Primary Use
Main feeder busbar bracing
EL Series Busbar Insulator
LV Busbar Clamp

EL Clamp

EL Series Busbar Insulator

Voltage Class
660 V – 1000 V AC
Material
Glass-Filled SMC
Thread / Mount
Adjustable Clamp
Primary Use
Power-conversion & MCC panels
EL Series High Voltage Busbar Insulator
MV / HV Support

EL HV Series

EL Series High Voltage Busbar Insulator

Voltage Class
6 kV – 36 kV MV/HV
Material
Cast Epoxy Resin
Thread / Mount
M10 – M16 Inserts
Primary Use
Medium/high-voltage switchgear
VIOX High Voltage Epoxy Resin Busbar Support Insulator
Cast Epoxy Resin

HV Epoxy Post

VIOX High Voltage Epoxy Resin Busbar Support Insulator

Voltage Class
10 kV – 36 kV MV/HV
Material
Low-PD Epoxy Resin
Thread / Mount
Custom Bolt Pattern
Primary Use
Substations & MV bus chambers
VIOX Copper Ground Bar Kit
Pre-Assembled Kit

Ground Bar Kit

VIOX Copper Ground Bar Kit

Voltage Class
Earthing & Bonding
Material
T2 Copper + SM Stand-Off
Thread / Mount
M6 – M10 Terminals
Primary Use
Telecom, data center & panel earthing
VIOX Customizable Busbar Stand-Off Bracket
Custom Bracket

Stand-Off Bracket

VIOX Customizable Busbar Stand-Off Bracket

Voltage Class
Custom Mounting
Material
Galvanized / Stainless Steel
Thread / Mount
Matched to SM / CT
Primary Use
Panel backplate stand-off mounting

Busbar Insulator Material & Geometry Selection Matrix

Compare molded DMC/BMC stand-offs, high-strength SMC switchgear supports, stepped/clamp assemblies, and cast epoxy resin HV insulators—including explicit application limits.

Engineering selection matrix across VIOX busbar insulator materials, voltage tiers, and limits
Insulator Construction VIOX Published Series Voltage & Mechanical Spec Limitations / Not Suitable For How to Verify Before Order
Molded DMC / BMC Stand-Offs SM (25–76 mm) · SM-B · SEP · TSM · SE 660 V – 1500 V AC/DC · M6–M12 inserts · UL94 V-0 Not suitable for medium-voltage switchgear (> 3.6 kV) or direct outdoor UV/rain exposure without an enclosure. Confirm overall height, insert depth, metal type & tightening torque.
High-Strength SMC Switchgear Supports MNS · C · D · 71 · SB · EN LV switchgear & MCCs · High cantilever short-circuit strength Requires matched busbar support spacing (per IEC 61439 Icw/Ipk) to prevent bar deformation under fault. Verify bar cross-section, span spacing & prospective fault kA.
Stepped & Multi-Bar Clamp Supports CT Stepped · REL · HL · DL · EL Clamp Staggered multi-phase clearance · Compact DB & inverter panels Fixed phase pitch—verify exact copper/aluminum busbar width and phase-to-phase center distance. Check bar dimensions (e.g. 5×20 mm to 10×100 mm) & cabinet depth.
Cast Epoxy Resin HV Insulators EL HV Series · HV Epoxy Post 6 kV – 36 kV MV/HV switchgear · Low partial discharge · High bending load Standard indoor epoxy chalks under direct sunlight—specify outdoor cycloaliphatic epoxy or porcelain if exposed. Confirm rated kV, BIL impulse level, creepage distance & bolt pattern.

Why Low-Grade Busbar Insulators Fail in Switchgear — And How VIOX Engineers Around It

A busbar support looks like a simple molded spacer—until short-circuit electrodynamic forces, high humidity, or bolt tightening torque expose weak compounds and loose inserts.

01Flashover

Phase-to-Ground Flashover & Tracking

Undersized insulator heights or low-CTI compounds allow conductive dust and humidity to bridge live busbars to grounded enclosures.

VIOX EngineeringMatched creepage/clearance geometry across SM25–SM76 stand-offs and ribbed HV epoxy insulators.
02Insert Pull-Out

Stripped or Pulled-Out Threaded Inserts

Shallow knurling or soft alloy inserts spin loose when installers torque M8/M10 busbar bolts—or shear off under short-circuit cantilever shock.

VIOX EngineeringDeep-knurled steel, brass, or SS304/316 inserts verified for tightening torque and axial pull-out strength.
03Arc Fire

Flame Spread During Internal Arcs

Recycled or non-UL94 V-0 polyester fillers char and propagate fire inside distribution switchboards during an internal arc-fault event.

VIOX EngineeringSelf-extinguishing UL94 V-0 unsaturated polyester DMC/BMC/SMC and electrical-grade epoxy compounds.
04Moisture

Moisture Absorption in Coastal Panels

Porous low-density BMC absorbs ambient humidity in tropical or outdoor cabinets, dropping insulation resistance during Megger checks.

VIOX EngineeringHigh-density compression molding + Indoor vs. Outdoor Selection Guide.

How VIOX Busbar Insulators Compare Across Industrial Tiers

Objective engineering benchmark across dimensional compatibility, insert metal options, HV epoxy depth, and custom CAD mold capability.

VIOX busbar insulator benchmark against global Tier-1 and entry-tier lines
Evaluation Parameter Global Tier-1 Industrial Lines Entry-Tier Commodity Lines VIOX SM / CT / Epoxy Line
Hex / Barrel LV Stand-Offs Standard 25–76 mm footprints at premium unit cost Inconsistent height tolerance & recycled filler SM / SM-B / SEP / TSM (UL94 V-0 · 40–60% lower cost)
Stepped & Multi-Bar Clamps Proprietary modular busbar support systems Limited to basic single-post spacers CT Stepped, REL, HL, DL, EL + Copper Ground Kits
MV / HV Cast Epoxy Insulators Specialty MV suppliers with long batch lead times No true 6 kV–36 kV low-PD epoxy capability EL HV & Cast Epoxy Support Insulators (6–36 kV)
Insert Metal Flexibility Fixed catalog thread/metal SKUs only Thin-wall zinc steel prone to thread stripping Deep-knurled Steel, Brass & SS304/316 (Metric/Imp.)
Custom Drawings & OEM Supply High tooling fees & rigid change cycles No in-house CAD or mold engineering In-house STEP/CAD mold review & OEM branding

Direct Factory Insulator Production

VIOX manufactures all 22 published busbar insulator series (660 V–36 kV) directly from compression-molding and epoxy-casting lines—verified for UL94 V-0 flame retardancy, Hi-Pot dielectric strength, insert torque/pull-out endurance, and custom STEP/CAD tooling for panel builders and OEM switchgear brands.

Busbar Insulator Quotation Variables — What Moves Unit Pricing

Four technical specifications govern your exact unit price and tooling scope. See also our 7 key cost drivers guide.

Quotation variables for VIOX busbar insulators
Quotation Variable Standard Catalog Baseline Heavy-Duty / Custom Specification Quote & Lead-Time Impact
1. Height & Body Series SM25 / SM30 / SM35 / SM40 stand-offs Tall SM51 / SM76, CT/EL clamps, or 10–36 kV HV epoxy Scales directly with compound weight & curing cycle
2. Insert Metal & Thread Zinc-plated carbon steel (M6 / M8 / M10) Solid brass (non-magnetic), SS304/316, or imperial UNC/UNF Brass & stainless inserts adjust raw hardware cost
3. Compound Grade & Color Standard red/orange UL94 V-0 DMC/BMC High-strength glass-filled SMC, high-CTI, or custom RAL color Moderate material delta + batch color run coordination
4. Existing Mold vs. Custom CAD Any of VIOX’s 22 published insulator series Custom height, bolt flange, or embedded stud from STEP/CAD Zero mold fee on published series; custom mold amortized on volume

Sourcing Standard SM/CT Busbar Insulators or Custom CAD Molds?

Share your height, thread size (M6–M12 or imperial), insert metal, voltage class, or STEP/PDF drawing—our factory engineers will return matched pricing and sample options.

Request Insulator Quote →

Busbar Insulator Engineering & Sourcing Questions

Direct answers on DMC/BMC vs. epoxy selection, footprint compatibility, insert metal torque, stepped CT layouts, and custom CAD molds.

Materials When should I choose molded DMC/BMC/SMC stand-offs (SM series) vs. cast epoxy resin busbar insulators?

Choose molded DMC, BMC, or SMC stand-offs (such as VIOX SM, SEP, TSM, or MNS series) for low-voltage switchgear, distribution panels, and inverter cabinets (660 V–1500 V AC/DC) where UL94 V-0 flame retardancy and cost efficiency govern.

Upgrade to cast epoxy resin insulators (VIOX EL HV and HV Epoxy Post series) for medium- and high-voltage switchgear (6 kV–36 kV), extreme short-circuit cantilever forces, or strict partial-discharge limits.

Compatibility Are VIOX SM-series busbar insulators mechanically compatible with standard IEC and North American stand-off footprints?

Yes. Standard VIOX SM-series heights (25 mm, 30 mm, 35 mm, 40 mm, 51 mm, 76 mm) with hex wrench flats and metric (M6, M8, M10, M12) or imperial thread inserts match common international switchgear and panelboard footprints.

Always verify exact overall height, barrel diameter, cantilever bending rating, and thread depth against your panel drawing before drop-in substitution.

Hardware Should I specify brass, zinc-plated steel, or stainless steel threaded inserts on busbar insulators?

Zinc-plated carbon steel inserts deliver the highest tightening torque and axial pull-out strength for standard indoor switchboards. Solid brass inserts provide superior corrosion resistance and non-magnetic performance around high-current AC busbars.

Specify stainless steel (SS304/SS316) inserts for coastal, marine, humid tropical, or chemical-plant enclosures.

Layout How do stepped busbar insulators (CT series) differ from standard single-height SM stand-offs?

A stepped busbar insulator (VIOX CT series) mounts 3-phase or 4-pole busbars at staggered elevations on a single compact base, maximizing phase-to-phase air clearance and creepage distance inside shallow cabinets.

Staggered tiers also give panel assemblers direct front access for torque-wrench lug termination without removing adjacent bars.

Quality QC How do I verify busbar insulator quality before approving a volume production order?

Request four verification checks on pre-production samples: (1) power-frequency dielectric withstand (Hi-Pot) test, (2) UL94 V-0 flame-retardancy compliance, (3) cantilever bending and insert torque/pull-out testing, and (4) height tolerance and thread perpendicularity inspection.

Custom Mold Can VIOX manufacture custom busbar insulators from a STEP/CAD drawing or physical sample?

Yes. Send your STEP/PDF drawing or physical sample specifying overall height, mounting bolt pattern, insert thread size and metal, compound grade/color, and estimated annual volume.

VIOX engineering reviews mold feasibility, tooling lead time, and factory unit pricing before any tooling begins.

Need the Right Busbar Insulator?
Let’s Confirm It Together.

Send your insulator height, thread size (M6–M12 or imperial), insert metal, voltage class, or CAD drawing. VIOX engineers will match the right SM, CT, or HV epoxy series.

Request Busbar Insulator Quote