VF003 Pinaliit na Circuit Breaker (MCB)

The VIOX VF003 is a 1P+N miniature circuit breaker for overload and short-circuit protection in low-voltage final distribution circuits. Current product data covers 2A to 32A, 120V and 230/400V to 240/415V applications at 50/60Hz, and breaking capacities of 3kA, 4.5kA, or 6kA. It mounts on a standard 35mm DIN rail and supports top or bottom connection.

Configuration
1P+N
Na-rate na Kasalukuyan
2A–32A
Breaking Kapasidad
3 / 4.5 / 6kA
Pamantayan
IEC/EN 60898-1

Curve, rating, accessories, and compliance documents confirmed before order

Pangkalahatang-ideya ng Produkto

The VIOX VF003 is a 1P+N miniature circuit breaker for overload and short-circuit protection in low-voltage final distribution circuits. It combines thermal overload protection, magnetic short-circuit tripping, and manual circuit isolation in a compact DIN-rail device.

Current product data covers rated currents from 2A to 32A, 120V and 230/400V to 240/415V applications at 50/60Hz, and breaking capacities of 3kA, 4.5kA, or 6kA. The VF003 is intended for residential, commercial, and selected industrial control or distribution circuits when its rating, trip curve, conductor capacity, and breaking capacity are correctly coordinated with the installation.

Mga Pangunahing Tampok

  • Thermal-magnetic overload and short-circuit protection
  • 1P+N configuration for final distribution circuits
  • Rated current options from 2A to 32A
  • Breaking capacity options of 3kA, 4.5kA, and 6kA
  • Energy limiting class 3
  • Contact-position indication
  • 35mm DIN-rail mounting with fast clip device
  • Top or bottom connection and compatible auxiliary accessories

Teknikal na Pagtutukoy

Electrical Data

ParameterPagtutukoy
ModeloVF003
Pole1P+N
Rated current (In)2A, 6A, 10A, 16A, 20A, 25A, 32A
Rated voltage (Ue)120V; 230/400V to 240/415V AC
Na-rate na dalas50/60Hz
Rated na boltahe ng pagkakabukod (Ui)500V
Na-rate na impulse withstand boltahe (Uimp)4kV
Rated breaking capacity3kA, 4.5kA, 6kA
Energy limiting class3
Trip curve shown in current technical tableB, C
Power-frequency dielectric test2kV for 1 minute
PamantayanIEC/EN 60898-1

Mechanical and Environmental Data

ParameterPagtutukoy
Buhay ng kuryente10,000 operasyon
Buhay na mekanikal20,000 operasyon
Contact-position indicatorOo
Protection degreeIP20
Reference temperature for thermal setting30°C
Temperatura sa paligid-5°C to 40°C; daily average not above 35°C
Temperatura ng imbakan-25°C hanggang 70°C
Degree ng polusyon2

Installation Data

ParameterPagtutukoy
Terminal connectionCable, U-type busbar, or pin-type busbar
Cable terminal capacityUp to 25mm² / 18–4 AWG
Busbar terminal capacityUp to 10mm² / 18–8 AWG
Paghihigpit ng metalikang kuwintas2.5N·m / 22in-lb
Pag-mount35mm DIN rail to EN 60715, fast clip device
Connection directionItaas o ibaba

Gabay sa Pagpili

Select the VF003 configuration by coordinating the protective device with the circuit load, conductor capacity, installation conditions, and prospective short-circuit current. Final selection should follow the applicable installation standard and project design.

Na-rate na Kasalukuyan

Choose a rated current from 2A to 32A that protects the installed conductor while supporting the design load and applicable correction factors.

Trip Curve

The current technical table lists B and C curves. Use the curve that matches the expected inrush characteristics and confirm availability for the ordered version.

Breaking Kapasidad

Select 3kA, 4.5kA, or 6kA only after confirming that the device rating exceeds the prospective short-circuit current at the installation point.

Mga sukat

The verified overall and mounting drawing for VF003 will be added here. Dimensions are not borrowed from another MCB model.

Mga application

Typical low-voltage final-distribution and control environments where the VF003 rating and protection characteristics may be coordinated with the circuit design.

  • Residential lighting, socket-outlet, and household final circuits
  • Commercial lighting, office equipment, and building distribution circuits
  • Industrial control and auxiliary circuits with suitable inrush characteristics

Pag-install at Pag-komisyon

Pag-mount

Install vertically on a standard 35mm DIN rail using the integrated fast clip. Maintain the enclosure clearances required by the installation design.

Mga kable

Use a conductor and terminal format within the stated capacity. Tighten terminals to 2.5N·m and verify that each conductor is fully secured before energizing.

Inspeksyon

Before commissioning, confirm mounting, conductor security, manual operation, circuit isolation, and protective-device coordination using appropriate test procedures.

Accessories and System Integration

Current VF003 product information lists compatibility with the following auxiliary functions. Confirm the matching accessory model and wiring arrangement before ordering.

  • Auxiliary contact for remote status indication
  • Shunt release for remote tripping
  • Undervoltage release for voltage-dependent disconnection
  • Alarm contact for trip indication

Compliance and Documentation

The current VF003 technical data identifies IEC/EN 60898-1 as the applicable miniature circuit breaker standard.

Documentation scope

Existing product material also references NF, UKCA, and CE. Certification and declaration documents should be confirmed for the selected version and destination market before they are used in a project submittal.

FAQ

What pole configuration does the VF003 use?

The current VF003 product data identifies the device as a 1P+N miniature circuit breaker.

Which rated currents are listed for VF003?

The listed rated-current options are 2A, 6A, 10A, 16A, 20A, 25A, and 32A.

Which breaking capacities are available?

Current product data lists 3kA, 4.5kA, and 6kA. The selected capacity must exceed the prospective short-circuit current at the installation point.

Which trip curves are shown in the technical table?

The current technical table lists B and C curves. Confirm the required curve and its availability when ordering.

Can the VF003 be supplied from the top or bottom?

The current installation data allows connection from the top or bottom, subject to the project wiring design.

Which auxiliary functions are referenced?

The current product material references auxiliary contact, shunt release, undervoltage release, and alarm contact compatibility.

Which compliance documents are available?

IEC/EN 60898-1 is identified in the technical data. NF, UKCA, CE, and destination-specific documentation should be confirmed for the selected version.

Need a VF003 MCB Quote?