VIOX VSP1-C40PV/2(S) 600V Pluggable Single-Pole SPD

VIOX VSP1-C40PV/2(S) 600V Pluggable Single-Pole SPD offers robust surge protection for photovoltaic systems and sub-distribution boards. This Class II/Type 2/Type 1CA device safeguards L-PE and N-PE modes with 20kA nominal and 40kA maximum discharge current. Featuring high-energy MOV elements, it operates at 600V DC with < 25ns response time. The pluggable design ensures easy installation on 35mm DIN rails. IEC 61643-11:2011 and EN 61643-11:2012 compliant, it provides a voltage protection level of 2.2kV. With IP20 protection, thermal safeguards, and optional remote contacts, this versatile SPD suits various electrical installations, combining reliability and performance for enhanced power system protection in demanding photovoltaic applications.

Send your requirements, we will quote for you within 12 hours​

VIOX VSP1-C40PV/2(S) 600V Pluggable Single-Pole SPD

Overview

The VIOX VSP1-C40PV/2(S) 600V is a high-performance Pluggable Single-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for L-PE and N-PE modes, making it an ideal solution for various electrical installations, particularly in photovoltaic systems.

Key Features

  • Class II, Type 2, Type 1CA device
  • Location of Use: Sub-Distribution Boards
  • Mode of Protection: L-PE, N-PE
  • Surge Ratings: In = 20 kA (8/20 μs)
  • IEC/EN/UL Category: Class II / Type 2 / Type 1CA
  • Protective Elements: High Energy MOV
  • Housing: Pluggable Design
  • Compliance: IEC 61643-11:2011, EN 61643-11:2012

Technical Specifications

IEC Electrical 600
Nominal AC Voltage 600V
Maximum Continuous Operating Voltage (DC) 600V
Nominal Discharge Current (8/20 μs) 20 kA
Maximum Discharge Current (8/20 μs) 40 kA
Impulse Discharge Current (10/350 μs) 6.25kA
Voltage Protection Level 2.2kV
Impulse Current (10/350μs) Iimp (L-N) 7kA
Response Time < 25 ns
Back-Up Fuse (max) 125 A gL / gG
Short-Circuit Current Rating (AC) 25 kA / 50 kA
TOV Withstand 5s ?
TOV 120min ?
mode Withstand, Safe Fail

Mechanical & Environmental Specifications

  • Operating Temperature Range: -40°F to +158°F [-40°C to +70°C]
  • Permissible Operating Humidity: 5%…95%
  • Atmospheric pressure and altitude: 80k Pa … 106k Pa / -500 m….2000 m
  • Terminal Screw Torque: 39.9 lbf.in [4.5 Nm]
  • Conductor Cross Section (max): 2 AWG (Solid, Stranded) / 4 AWG (Flexible)
  • 35 mm² (Solid, Stranded) / 25 mm²(Flexible)
  • Mounting: 35 mm DIN Rail, EN 60715
  • Degree of Protection: IP 20 (built-in)
  • Housing Material: Thermoplastic: Extinguishing Degree UL 94 V-0
  • Thermal Protection: Yes
  • Operating State / Fault Indication: Green ok / Red defect

Additional Features

  • Remote Contacts (RC): Optional
  • RC Switching Capacity: AC: 250V / 0.5 A; DC: 250V / 0.1 A;125V / 0.2 A;75V / 0.5 A
  • RC Conductor Cross Section (max): 16 AWG (Solid) / 1.5 mm²(Solid)

Internal Configuration

Dimension

Connection Diagram