The VIOX VRL7E is an electronic Type AC RCBO for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N design combines residual-current, overload and short-circuit protection with 2-40 A ratings, B or C tripping characteristics and 10, 30 or 100 mA sensitivities. It provides a 4.5 kA short-circuit capacity and mounts on a standard 35 mm DIN rail.

Nilai Semasa
2-40 A
Arus Baki
10, 30, 100 mA
Konfigurasi Tiang
1P+N
Kapasiti Pecah
4.5 kA

Gambaran keseluruhan

The VIOX VRL7E is an electronic Type AC residual current circuit breaker with overcurrent protection for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N configuration combines residual-current, overload and short-circuit protection in one compact device. The Type AC detection system responds to sinusoidal alternating residual currents, while B and C thermomagnetic tripping characteristics support different circuit and load requirements. The RCBO is intended for residential, commercial and light industrial distribution boards and installs on a standard 35 mm DIN rail.

Ciri-ciri

  • Electronic Type AC residual-current detection.
  • Residual-current, overload and short-circuit protection.
  • 1P+N configuration for AC 230 V circuits.
  • B and C thermomagnetic release characteristics.
  • 4.5 kA rated short-circuit capacity.
  • Penunjuk arus kerosakan bersepadu.
  • 35 mm DIN-rail mounting with a fast-clip device.

Spesifikasi

Data Elektrik

ParameterSpesifikasi
Operating ModeElectronic type
Nilai Semasa2, 4, 6, 10, 16, 20, 25, 32, 40 A
Konfigurasi Tiang1P+N
Voltan Operasi Dinilai230 V AC
Kekerapan Dinilai50/60 Hz
Voltan Penebat Terkadar250 V
Impuls Dinilai Menahan Voltan4 kV, 1.2/50 μs
Voltan Ujian Dielektrik2 kV selama 1 minit

Data Perlindungan

ParameterSpesifikasi
Residual-Current TypeTaip AC
Thermomagnetic Release CharacteristicB, C
Arus kendalian baki berkadar10, 30, 100 mA
Keupayaan Membuat dan Memutus Arus Baki Terkadar500 A
Rated Short-Circuit Capacity4.5 kA
Break Time at IΔn≤ 0.1 s
Ijazah Pencemaran2

Data Mekanikal dan Pemasangan

ParameterSpesifikasi
Kehidupan Elektrik4,000 operasi
Kehidupan Mekanikal10,000 operasi
Fault-Current IndicatorYa
Darjah PerlindunganIP20
Terminal ConnectionCable / pin-type busbar / U-type busbar
Cable Terminal Capacity25 mm², AWG 18-5, top/bottom
Busbar Terminal Capacity25 mm², AWG 18-3, top/bottom
Melekap35 mm DIN rail to EN 60715; fast-clip device
Supply ConnectionFrom top

Environmental Data

ParameterSpesifikasi
Suhu Ambien-5 °C to +40 °C; daily average ≤ 35 °C
Suhu Penyimpanan-25 °C to +70 °C

Standard

ParameterSpesifikasi
StandardIEC/EN 61009-1

Panduan Pemilihan

Elemen KodMaknanyaNilai Tersedia
VPengenalan perusahaan VIOXV
RLKeluarga produk RCBORL
7ESiri reka bentuk7E
KelukLengkung pelantikan arus lebihB atau C
semasaNilai semasa2-40 A
SensitivitiArus kendalian baki berkadar10, 30 or 100 mA
TiangOrdering designation2P in the catalog example
Example ModelKonfigurasi
VRL7E-B16-10B curve, 16 A, 10 mA
VRL7E-C20-30C curve, 20 A, 30 mA
VRL7E-C40-100C curve, 40 A, 100 mA

Keluk tersandung

Select a B or C thermomagnetic release characteristic according to the circuit and load requirements.

Nilai Semasa

Select one of the listed ratings from 2 A to 40 A.

Kepekaan Baki

Select a rated residual operating current of 10, 30 or 100 mA.

Konfigurasi Litar

The technical specification identifies a 1P+N configuration for AC 230 V final distribution circuits.

Keluk Perjalanan

The VRL7E is available with B and C time-current tripping characteristics. The catalog provides time-current graphs for both curves and specifies a residual-current break time of no more than 0.1 seconds at IΔn.

Protection CharacteristicAvailable Option
Thermomagnetic ReleaseB or C curve
Residual-Current Break Time≤ 0.1 s at IΔn

Dimensi

VRL7E Type AC RCBO dimensional drawing
VRL7E Type AC RCBO dimensional drawing.

Aplikasi

  • Residential final distribution boards.
  • Commercial final distribution circuits.
  • Light industrial distribution boards.
  • AC 230 V circuits requiring combined Type AC residual-current and overcurrent protection.

Pemasangan

  • Install on a 35 mm DIN rail conforming to EN 60715 using the fast-clip device.
  • Connect the supply from the top.
  • Use cable, pin-type busbar or U-type busbar connections as specified.
  • Observe the stated 25 mm² terminal capacity for cable and busbar connections.
  • Install within the specified ambient temperature range of -5 °C to +40 °C.

Soalan Lazim

What residual-current type does the VRL7E use?

It uses electronic Type AC detection for sinusoidal alternating residual currents.

Apakah arus berkadar yang tersedia?

The available ratings are 2, 4, 6, 10, 16, 20, 25, 32 and 40 A.

Which residual-current sensitivities are available?

The available rated residual operating currents are 10, 30 and 100 mA.

What is the VRL7E short-circuit capacity?

The rated short-circuit capacity is 4.5 kA.

How is the VRL7E installed?

It mounts on a 35 mm DIN rail conforming to EN 60715 and uses a fast-clip device. The supply connection is from the top.

Perlukan Sebut Harga Produk?
Mari Bina Bersama.

Hantarkan model produk, kadaran teknikal, kuantiti, dan keperluan OEM kepada kami. Pasukan kami akan menyemak permohonan anda dan memberi maklum balas dalam masa satu hari bekerja.

Minta Sebut Harga