VF003 Pemutus Litar Miniatur (MCB)

The VIOX VF003 is a 1P+N miniature circuit breaker for overload and short-circuit protection in low-voltage final distribution circuits. Current product data covers 2A to 32A, 120V and 230/400V to 240/415V applications at 50/60Hz, and breaking capacities of 3kA, 4.5kA, or 6kA. It mounts on a standard 35mm DIN rail and supports top or bottom connection.

Konfigurasi
1P+N
Nilai Semasa
2A–32A
Kapasiti Pecah
3 / 4.5 / 6kA
Standard
IEC/EN 60898-1

Curve, rating, accessories, and compliance documents confirmed before order

Gambaran Keseluruhan Produk

The VIOX VF003 is a 1P+N miniature circuit breaker for overload and short-circuit protection in low-voltage final distribution circuits. It combines thermal overload protection, magnetic short-circuit tripping, and manual circuit isolation in a compact DIN-rail device.

Current product data covers rated currents from 2A to 32A, 120V and 230/400V to 240/415V applications at 50/60Hz, and breaking capacities of 3kA, 4.5kA, or 6kA. The VF003 is intended for residential, commercial, and selected industrial control or distribution circuits when its rating, trip curve, conductor capacity, and breaking capacity are correctly coordinated with the installation.

Ciri-ciri Utama

  • Thermal-magnetic overload and short-circuit protection
  • 1P+N configuration for final distribution circuits
  • Rated current options from 2A to 32A
  • Breaking capacity options of 3kA, 4.5kA, and 6kA
  • Energy limiting class 3
  • Contact-position indication
  • 35mm DIN-rail mounting with fast clip device
  • Top or bottom connection and compatible auxiliary accessories

Spesifikasi Teknikal

Electrical Data

ParameterSpesifikasi
ModelVF003
Tiang1P+N
Arus terkadar (In)2A, 6A, 10A, 16A, 20A, 25A, 32A
Voltan berkadar (Ue)120V; 230/400V to 240/415V AC
**额定频率**50/60Hz
Voltan penebat berkadar (Ui)500V
Voltan tahan impuls berkadar (Uimp)4kV
Kapasiti pemutusan berkadar3kA, 4.5kA, 6kA
Kelas pengehadan tenaga3
Trip curve shown in current technical tableB, C
Power-frequency dielectric test2kV for 1 minute
StandardIEC/EN 60898-1

Mechanical and Environmental Data

ParameterSpesifikasi
Kehidupan elektrik10,000 operasi
Kehidupan mekanikal20,000 operasi
Contact-position indicatorYa
Darjah perlindunganIP20
Reference temperature for thermal setting30°C
Suhu persekitaran-5°C to 40°C; daily average not above 35°C
Suhu penyimpanan-25°C hingga 70°C
Tahap pencemaran2

Installation Data

ParameterSpesifikasi
Terminal connectionCable, U-type busbar, or pin-type busbar
Cable terminal capacityUp to 25mm² / 18–4 AWG
Busbar terminal capacityUp to 10mm² / 18–8 AWG
Tork mengetatkan2.5N·m / 22in-lb
Melekap35mm DIN rail to EN 60715, fast clip device
Connection directionAtas atau bawah

Panduan Pemilihan

Select the VF003 configuration by coordinating the protective device with the circuit load, conductor capacity, installation conditions, and prospective short-circuit current. Final selection should follow the applicable installation standard and project design.

Nilai Semasa

Choose a rated current from 2A to 32A that protects the installed conductor while supporting the design load and applicable correction factors.

Keluk Perjalanan

The current technical table lists B and C curves. Use the curve that matches the expected inrush characteristics and confirm availability for the ordered version.

Kapasiti Pecah

Select 3kA, 4.5kA, or 6kA only after confirming that the device rating exceeds the prospective short-circuit current at the installation point.

Dimensi

The verified overall and mounting drawing for VF003 will be added here. Dimensions are not borrowed from another MCB model.

Aplikasi

Typical low-voltage final-distribution and control environments where the VF003 rating and protection characteristics may be coordinated with the circuit design.

  • Residential lighting, socket-outlet, and household final circuits
  • Commercial lighting, office equipment, and building distribution circuits
  • Industrial control and auxiliary circuits with suitable inrush characteristics

Pemasangan dan Pentauliahan

Melekap

Install vertically on a standard 35mm DIN rail using the integrated fast clip. Maintain the enclosure clearances required by the installation design.

Pendawaian

Use a conductor and terminal format within the stated capacity. Tighten terminals to 2.5N·m and verify that each conductor is fully secured before energizing.

Pemeriksaan

Before commissioning, confirm mounting, conductor security, manual operation, circuit isolation, and protective-device coordination using appropriate test procedures.

Accessories and System Integration

Current VF003 product information lists compatibility with the following auxiliary functions. Confirm the matching accessory model and wiring arrangement before ordering.

  • Auxiliary contact for remote status indication
  • Shunt release for remote tripping
  • Undervoltage release for voltage-dependent disconnection
  • Alarm contact for trip indication

Compliance and Documentation

The current VF003 technical data identifies IEC/EN 60898-1 as the applicable miniature circuit breaker standard.

Documentation scope

Existing product material also references NF, UKCA, and CE. Certification and declaration documents should be confirmed for the selected version and destination market before they are used in a project submittal.

Soalan Lazim

What pole configuration does the VF003 use?

The current VF003 product data identifies the device as a 1P+N miniature circuit breaker.

Which rated currents are listed for VF003?

The listed rated-current options are 2A, 6A, 10A, 16A, 20A, 25A, and 32A.

Which breaking capacities are available?

Current product data lists 3kA, 4.5kA, and 6kA. The selected capacity must exceed the prospective short-circuit current at the installation point.

Which trip curves are shown in the technical table?

The current technical table lists B and C curves. Confirm the required curve and its availability when ordering.

Can the VF003 be supplied from the top or bottom?

The current installation data allows connection from the top or bottom, subject to the project wiring design.

Which auxiliary functions are referenced?

The current product material references auxiliary contact, shunt release, undervoltage release, and alarm contact compatibility.