Quick Answer: Set It in 3 Steps

  1. Set the current time. On the VIOX TB388, turn the center minute-hand knob clockwise, following its arrow, until the current time aligns with the fixed time marker. Do not force it backward or turn the large dial plate itself.
  2. Set the ON period. On the TB388, fold the required segments outward for ON and leave the other segments inward for OFF. Other models may work in the opposite direction: follow your own dial’s ON/OFF legend, not a universal “push in” rule.
  3. Switch to AUTO. Choose AUTO/timer mode, not constant ON or constant OFF. The dial should advance slowly with time, and the load should switch at the programmed boundaries.

Example: ON at 18:00, OFF at 23:00. This is 5 hours: set 20 consecutive segments on a 96-segment dial (20 x 15 minutes), or 10 on a 48-segment dial (10 x 30 minutes). Set the interval beginning at 18:00; the segment beginning at 23:00 stays OFF.

How Much Time Is One Pin? 15- vs 30-Minute Dials

The 24-hour dial represents a full day, with each segment representing the minimum setting unit for that model. Count intervals, not just the printed hour numbers.

Dial Time per segment VIOX example and published specification fields Segments for 18:00-23:00
96 segments per day 15 minutes TB388: “Number of operations: 96 as standard”; “Minimum Unit: 15 minutes” 20
48 segments per day 30 minutes SUL181h: “Set up times: 48 ON or OFF per day”; “Minimum setting unit: 30 minutes” 10

These values come from the product specification tables. Check your exact model’s table and instructions, particularly if a headline or sales description gives a different interval. The SUL181h example here uses its specification-table value of 30 minutes.

To identify your timer, count the segments around a complete daily ring or check the dial legend and model nameplate. Do not assume a similar-looking timer has the same interval or ON direction. Each segment controls an interval; a run of adjacent ON segments makes one continuous ON period.

Step-by-Step: Setting the Pins

Read the Clock Dial Before Changing It

Identify the fixed current-time pointer, the daily scale, the setting segments, and the manual override switch. The pointer is the reference for setting the time; it is not the place where every ON period must begin.

The TB388 uses a 24-hour schedule: 18:00 means 6 PM and 23:00 means 11 PM. Do not confuse morning and afternoon. The physical location of midnight or noon depends on the rotating dial’s position, so do not use a rule such as “midnight is always at the top.”

Set the Current Time

Rotate the TB388’s minute-hand knob only in the indicated direction until the correct daily time reaches the pointer. Verify time accuracy with a clock or watch. Do not rotate the large dial plate directly or force the mechanism backward. For another model, use the adjustment control and direction shown in its instructions.

Set Every Segment in the Required Interval

For the TB388, the printed legend and operating instructions specify outside = ON, inside = OFF. Set every segment covering the desired operating interval, rather than moving only the start and finish segments.

For the evening lighting example, locate 18:00 and work through the segments up to 23:00. Leave the interval starting at 23:00 OFF. Count the selected segments against the table above; an extra segment extends operation beyond your intended finish time.

The TB388 manual warns against forcing the setting pins immediately beside its current-time pointer. If a required segment is in that restricted area, follow the manual’s adjustment procedure rather than prying it. Do not remove built-in segments or use loose replacement pins unless the model is designed for them.

TB388 setting-ring illustration with segments set outward for the 18:00 to 23:00 ON period
Photo-based TB388 setting illustration, not a scale drawing: outside is ON and inside is OFF. The selected interval runs from 18:00 up to 23:00; use your own timer’s legend for its pin direction.

Return to AUTO and Check the Schedule

Set the manual switch to AUTO after testing. ON holds the output on regardless of the pins; OFF holds it off. An override left in either position can make a correctly programmed timer appear faulty.

Check that the displayed current time remains correct after adjustment. Observe the load at the next programmed change. The clock moves slowly, so an apparently stationary dial in a quick glance does not by itself prove failure. Keep a photo of the final settings for future reference.

What Is a Timer Switch with Pins?

A timer switch with pins, also called a mechanical timer switch or pin timer, uses a rotating daily clock dial and physical pins or segments to turn electrical circuits on and off at predetermined times.

Key components are the clock dial, timing pins or segments, manual override switch, electrical terminals, and mounting arrangement. The clock advances the schedule; the segments determine the ON/OFF intervals; the override temporarily bypasses the schedule.

VIOX TM1S mechanical timer showing its daily clock dial and programming segments
Existing TM1S product image. Check the instructions for its controls; the TB388 pin-direction example above is model-specific.

Installation: Finish the Electrical Work Before Programming

This setting procedure assumes the timer is correctly installed and its user controls are safely accessible. Always turn off power at the circuit breaker before electrical work and have a qualified electrician isolate and verify the circuit is dead before accessing terminals.

Take a photo of existing wire connections for reference before an authorized replacement. Connections, supply requirements, load ratings, mounting, and enclosure suitability must follow the exact timer’s instructions. Do not identify a terminal’s function by wire color alone or copy another timer’s terminal arrangement.

For the wiring task, use common timer switch wiring methods alongside the model’s diagram. After installation, the electrician can restore power, confirm clock operation and manual control, and hand over the timer for programming. Setting pins does not correct a wiring fault.

Troubleshooting: Check the Settings First

Symptom Setting check
Load stays ON Confirm the override is AUTO, not ON; check whether all segments were accidentally selected.
Load stays OFF Confirm AUTO, the current time, and the model’s ON-segment direction.
Switching happens at the wrong hour Check morning versus afternoon and alignment with the fixed pointer.
Switching finishes too early or late Recount segments and confirm whether each represents 15 or 30 minutes.
Clock does not advance Check settings against the instructions; have an electrician assess supply or mechanism faults.

Verify that pins are securely in their intended positions. Do not force loose or jammed parts, expose live terminals, or repeatedly override equipment to conceal a fault. For diagnosis beyond programming, see mechanical timer troubleshooting.

Selection: Keep the Timer Matched to the Task

Lighting systems, ventilation fans, and pool equipment may use daily schedules, but their electrical requirements differ. Check the exact timer’s supply, load category, contact rating, mounting, and environment before choosing or replacing it.

Timer type Programming method
Pin timer Physical segments on a repeating clock dial
Digital timer Buttons and a display
Smart timer Connected controls, depending on the product

For a broader comparison, read timer switch types, functions and applications. The instructions here concern an installed pin timer, not digital menus or timer-relay terminal wiring.

Frequently Asked Questions

Do I Push Timer Pins In or Out for ON?

Read the model’s legend. TB388 specifies outward for ON and inward for OFF. Another timer may reverse this, so appearance alone is not a reliable guide.

Does One Pin Mean 15 Minutes?

Only on a dial with that setting unit. TB388 specifies 15 minutes; the SUL181h specification table gives 30 minutes. Count the segments or check the exact model’s instructions.

Can I Set a Schedule Across Midnight?

Yes, on a daily dial: select the required evening intervals through midnight and continue through the early-morning intervals. Leave the segment beginning at the desired finish time OFF.

Do I Need to Reset the Pins After a Power Outage?

The physical pin positions remain set, but the clock may need correcting if its reserve is absent or exhausted. Check the displayed time after power returns and consult the model’s instructions.

Conclusion

Set the current time, select the ON intervals using your model’s pin direction, and return the override to AUTO. Verify the segment duration before counting the schedule, then check an actual switching boundary. Keep installation and fault diagnosis separate from programming.