MC4-Compatible Solar Connector Manufacturer for PV Systems
VIOX supplies inline, multi-branch and Y-branch photovoltaic connectors for distributors, installers, equipment builders and OEM programs. Compare real VOPV models by connection format, voltage, current and PV cable size.
- 1000 V and 1500 V model options
- 2.5–10 mm² published cable options
- Inline and branch configurations
Start with the connection architecture.
Choose the physical arrangement first. Then verify voltage, current, cable, contact, seal and mating-system data for the exact model.

VOPV-01 Inline Connector
A representative male-and-female cable connector pair from the VOPV inline range.
- Stored current
- 30 A
- Stored voltage
- 1000 V DC
- Cable options
- 2.5 / 4 / 6 mm²
- Selection check
- Cable OD, contact and seal

VOPV-03-01 Connector
The stored product data identifies this inline model for a higher current and larger cable cross-section than the standard 30 A examples.
- Stored current
- 50 แอมแปร์
- Stored voltage
- 1500 โวลต์กระแสตรง
- Cable option
- 10 mm²
- Selection check
- Exact contact and cable construction

VOPV-T Multi-Branch Series
Published T-series products cover two-way through six-way branch arrangements. Confirm the permitted parallel-string architecture before specification.
- แบบจำลอง
- VOPV-T3 ถึง VOPV-T7
- Stored current
- 50 แอมแปร์
- Stored voltage
- 1500 V IEC / 800 V UL
- Cable options
- 2.5 / 4 / 6 mm²

VOPV-Y Branch Series
Y-style branch products provide a different cable-routing format from the T-series. Select the exact branch and polarity arrangement.
- แบบจำลอง
- VOPV-Y3 ถึง VOPV-Y5
- Stored current
- 30 A
- Stored voltage
- 1000 V IEC / 800 V UL
- Cable options
- 2.5 / 4 / 6 mm²
Build the range from real VOPV models.
Every card links to an existing product detail. Ratings shown here come from the current stored VIOX model data and remain subject to exact datasheet confirmation.

วีโอพีวี-07
Solar PV connector · Inline connector- ปัจจุบัน
- 30 A
- Voltage
- 1000 V DC
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วปพ.06
Solar PV connector · Inline connector- ปัจจุบัน
- 30 A
- Voltage
- 1500 โวลต์กระแสตรง
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วปพ.05
Solar PV connector · Inline connector- ปัจจุบัน
- 30 A
- Voltage
- 1000 V DC
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วปพ.04
Solar PV connector · Inline connector- ปัจจุบัน
- 30 A
- Voltage
- 1000 V DC
- สายเคเบิล
- 2.5 / 4 / 6 mm²

VOPV-03-01
Solar PV connector · Inline connector- ปัจจุบัน
- 50 แอมแปร์
- Voltage
- 1500 โวลต์กระแสตรง
- สายเคเบิล
- 10 mm²

วีโอพีวี-03
Solar PV connector · Inline connector- ปัจจุบัน
- 30 A
- Voltage
- 1500 โวลต์กระแสตรง
- สายเคเบิล
- 2.5 / 4 / 6 / 10 mm²

วีโอพีวี-02
Solar PV connector · Inline connector- ปัจจุบัน
- 30 A
- Voltage
- 1000 V DC
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วีโอพีวี-01
Solar PV connector · Inline connector- ปัจจุบัน
- 30 A
- Voltage
- 1000 V DC
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วีโอพีวี-ที 7
Solar PV connector · 6-way branch- ปัจจุบัน
- 50 แอมแปร์
- Voltage
- 1500 V IEC / 800 V UL
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วีโอพีวี-ที6
Solar PV connector · 5-way branch- ปัจจุบัน
- 50 แอมแปร์
- Voltage
- 1500 V IEC / 800 V UL
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วีโอพีวี-ที5
Solar PV connector · 4-way branch- ปัจจุบัน
- 50 แอมแปร์
- Voltage
- 1500 V IEC / 800 V UL
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วีโอพีวี-ที4
Solar PV connector · 3-way branch- ปัจจุบัน
- 50 แอมแปร์
- Voltage
- 1500 V IEC / 800 V UL
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วีโอพีวี-ที3
Solar PV connector · 2-way branch- ปัจจุบัน
- 50 แอมแปร์
- Voltage
- 1500 V IEC / 800 V UL
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วปพ.ย5
Solar PV connector · Multi-Y branch- ปัจจุบัน
- 30 A
- Voltage
- 1000 V IEC / 800 V UL
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วปพ.ย4
Solar PV connector · Y branch- ปัจจุบัน
- 30 A
- Voltage
- 1000 V IEC / 800 V UL
- สายเคเบิล
- 2.5 / 4 / 6 mm²

วปพ.ย3
Solar PV connector · Y branch- ปัจจุบัน
- 30 A
- Voltage
- 1000 V IEC / 800 V UL
- สายเคเบิล
- 2.5 / 4 / 6 mm²
Compare the stored model data.
Use this table to narrow the range, then request the current datasheet, dimensional drawing and applicable approval document for the exact ordered reference.
| แบบอย่าง | การกำหนดค่า | กระแสไฟฟ้าที่กำหนด | แรงดันไฟฟ้าที่กำหนด | ขนาดสายเคเบิล | Detail |
|---|---|---|---|---|---|
| วีโอพีวี-07 | Inline connector | 30 A | 1000 V DC | 2.5 / 4 / 6 mm² | View product |
| วปพ.06 | Inline connector | 30 A | 1500 โวลต์กระแสตรง | 2.5 / 4 / 6 mm² | View product |
| วปพ.05 | Inline connector | 30 A | 1000 V DC | 2.5 / 4 / 6 mm² | View product |
| วปพ.04 | Inline connector | 30 A | 1000 V DC | 2.5 / 4 / 6 mm² | View product |
| VOPV-03-01 | Inline connector | 50 แอมแปร์ | 1500 โวลต์กระแสตรง | 10 mm² | View product |
| วีโอพีวี-03 | Inline connector | 30 A | 1500 โวลต์กระแสตรง | 2.5 / 4 / 6 / 10 mm² | View product |
| วีโอพีวี-02 | Inline connector | 30 A | 1000 V DC | 2.5 / 4 / 6 mm² | View product |
| วีโอพีวี-01 | Inline connector | 30 A | 1000 V DC | 2.5 / 4 / 6 mm² | View product |
| วีโอพีวี-ที 7 | 6-way branch | 50 แอมแปร์ | 1500 V IEC / 800 V UL | 2.5 / 4 / 6 mm² | View product |
| วีโอพีวี-ที6 | 5-way branch | 50 แอมแปร์ | 1500 V IEC / 800 V UL | 2.5 / 4 / 6 mm² | View product |
| วีโอพีวี-ที5 | 4-way branch | 50 แอมแปร์ | 1500 V IEC / 800 V UL | 2.5 / 4 / 6 mm² | View product |
| วีโอพีวี-ที4 | 3-way branch | 50 แอมแปร์ | 1500 V IEC / 800 V UL | 2.5 / 4 / 6 mm² | View product |
| วีโอพีวี-ที3 | 2-way branch | 50 แอมแปร์ | 1500 V IEC / 800 V UL | 2.5 / 4 / 6 mm² | View product |
| วปพ.ย5 | Multi-Y branch | 30 A | 1000 V IEC / 800 V UL | 2.5 / 4 / 6 mm² | View product |
| วปพ.ย4 | Y branch | 30 A | 1000 V IEC / 800 V UL | 2.5 / 4 / 6 mm² | View product |
| วปพ.ย3 | Y branch | 30 A | 1000 V IEC / 800 V UL | 2.5 / 4 / 6 mm² | View product |
Treat the connector as a matched PV system.
Housing shape alone does not establish a safe or approved connection. Qualify every part of the assembled interface.
Cable construction
Confirm conductor cross-section, stranding, insulation material and outer diameter.
Contact and crimp
Match the contact part, strip length, die, crimp tool and inspection method.
Male and female pair
Use a documented mating combination; do not assume cross-brand compatibility.
DC electrical duty
Check maximum system voltage, operating current, temperature and branch-current path.
Seal and assembly
Verify the correct seal, gland, locking parts, tightening and fully mated condition.
Documents and market
Request the exact datasheet, drawing, assembly instruction and applicable approval record.
Qualify the order through the assembly controls.
A reliable order keeps connector housing, contact, cable, tooling, sample and batch identification connected to one approved reference.

Match cable, contact and tooling before production.
Record conductor construction, cable outer diameter, contact reference, die and crimp-tool requirement in the quotation and sample file.

Review the exact model against the project requirement.
Voltage, current, connection arrangement, environmental duty and requested documents are checked at model level rather than represented by a generic certificate strip.

Preserve the approved configuration for repeat orders.
Keep the final model, contact, seal, cable range, marking and packaging version tied to replenishment orders.
OEM photovoltaic connector supply with a controlled release path.
Commercial customization follows technical selection, not the other way around.
Define the PV architecture
State inline, panel, T-branch, Y-branch or fuse-connector arrangement and the current path.
Confirm cable and electrical data
Provide cable cross-section and diameter, system voltage, operating current and installation conditions.
Match the connector system
Align housing, contact, seal, polarity, mating pair, crimp tool and assembly instruction.
Review documents and sample
Confirm the applicable model documents, physical sample and required project records.
Approve marking and packaging
Release logo, label, instruction and packaging only after the technical reference is fixed.
Turn the PV requirement into a quote-ready connector brief.
A complete brief helps VIOX return the relevant model, document and sample route without guessing.
- Target market and PV application
- Maximum DC voltage and operating current
- Cable cross-section, construction and outer diameter
- Inline, panel or branch arrangement and quantity
- Required approvals, drawings, tooling, branding and packaging
Ready to compare the complete connector system?
Send the cable and electrical details above for model-level technical and commercial review.
Request a solar connector quote Final ratings, compatibility, documents and commercial scope are confirmed during quotation.Questions before a solar connector order.
Answers are limited to the current VIOX model records and safe connector-system selection practice.
Are VIOX connectors Original MC4 products?
No. MC4 is a protected trademark of Stäubli. This page presents VIOX MC4-compatible photovoltaic connectors and does not represent them as Original MC4 products.
Can male and female solar connectors from different brands be mated?
Do not assume compatibility from a similar shape or the MC4-compatible description. Use a documented male and female connector pair approved for the installation, with the specified contacts, seals, cable and assembly tools.
Which VOPV models are listed for 1000 V and 1500 V DC systems?
The stored VIOX data lists both 1000 V and 1500 V options. Ratings vary by model and, for branch products, by the applicable IEC or UL record. Confirm the exact model datasheet and system design before selection.
Which PV cable sizes are shown for the VOPV range?
The stored model data includes 2.5 mm², 4 mm² and 6 mm² options, with selected VOPV-03 variants also showing 10 mm². Cable outer diameter, conductor construction, contact and sealing range must also match.
What is the difference between VOPV, VOPV-T and VOPV-Y connectors?
VOPV models are inline cable or panel-connection formats. VOPV-T models provide multi-branch arrangements, while VOPV-Y models provide Y-style branch arrangements. Confirm branch count, polarity, current path and permitted system architecture.
What information should be sent for an MC4-compatible connector quotation?
Send the system voltage and current, cable cross-section and outer diameter, inline or branch arrangement, connector quantity, target market, required documents, tooling needs, branding and packaging requirements.