VIOX ELECTRIC
Langue

VIOX VM6EY-MP3/JLY Series Intelligent Four-Remote MCCB (250A–630A)

VIOX VM6EY-MP3/JLY Series Intelligent Four-Remote Circuit Breaker (250 A and 630 A frames; 50 A–630 A adjustable; AC 400 V; 50 kA Icu; Icw 10 kA/1s) unites an electronic metering MCCB with a factory-integrated DC6 rapid actuator (≤1 s response) for complete telemetry, tele-signaling, tele-control, and tele-adjustment.

Frame Range
250 A & 630 A (50–630 A)
Vitesse de réponse
Four-Remote Quick Action ≤ 1 s
Breaking & Icw
50 kA Icu · 35–50 kA Ics · 10 kA/1s
Intégration
Built-in Metering + DC6 Actuator

Vue d'ensemble

The VIOX VM6EY-MP3/JLY Series is a factory-integrated intelligent four-remote molded case circuit breaker combining an electronic Class B metering MCCB with a built-in DC6 rapid electric actuator. Covering 250 A (50–250 A) and 630 A (160–630 A) frames at AC 400 V (Ui 1000 V, Uimp 8 kV, 50 kA Icu, Icw 10 kA/1s), VM6EY-MP3/JLY delivers ≤1 s remote switching, high-precision electrical measurement, and plug-and-play SCADA connectivity in one compact unit.

Caractéristiques

  • Complete four-remote capability (telemetry, tele-signaling, tele-control, tele-adjustment) in one integrated unit.
  • Ultra-fast ≤1 s remote opening and closing response via factory-matched DC6 actuator.
  • 50 kA Icu breaking capacity (35 kA Ics on 250 A; 50 kA Ics on 630 A) and 10 kA/1s short-time withstand (Icw).
  • Integrated electrical measurement function with front LCD settings and ON/TRIPPED/OFF status.
  • Compact single-body installation reduces panel wiring and commissioning time.
  • Rated Ui = 1000 V, Uimp = 8 kV, AC 400 V 50/60 Hz.

Modèles

ModèleAdjustable Rated Current In (A)Ue / Ui / UimpIcu / Ics (400 V)Icw & Response
VM6EY-250MP3/JLY125 A (50–125 A) · 250 A (100–250 A)AC 400 V / 1000 V / 8 kV50 kA / 35 kA10 kA/1s · ≤ 1 s
VM6EY-630MP3/JLY400 A (160–400 A) · 630 A (252–630 A)AC 400 V / 1000 V / 8 kV50 kA / 50 kA10 kA/1s · ≤ 1 s

Spécifications

Electrical & Control Specifications

ParamètreVM6EY-250MP3/JLYVM6EY-630MP3/JLY
Rated working voltage UeAC 400 VAC 400 V
Rated insulation / UimpAC 1000 V / 8 kVAC 1000 V / 8 kV
Rated short-time withstand Icw10 kA / 1 s10 kA / 1 s
Breaking capacity Icu / Ics50 kA / 35 kA50 kA / 50 kA
Operation quick response time≤ 1 s≤ 1 s

Guide de sélection

Position du codeSignificationCatalog Value or Options
VM6EYSérieElectronic LCD metering MCCB platform
250 / 630Courant de châssis250 A (50–250 A) or 630 A (160–630 A)
MP3/JLYIntegrated packageFactory-integrated DC6 rapid actuator + four-remote metering module

1. Deploy Turnkey Four-Remote

Order VM6EY-MP3/JLY when you want breaker, metering, and motorized drive pre-assembled and factory-tested.

2. Verify ≤1 s Actuation

Rapid opening/closing supports automated feeder transfer and demand-response load shedding.

3. Match Fault Capacity

50 kA Icu and 10 kA/1s Icw fit commercial and utility substation feeders.

4. Connect RS485/SCADA

Wire L/N/A/B/S2/S4 bottom terminals directly to your RTU or EMS gateway.

Installation

  • Connect control power and RS485 A/B terminals on the bottom terminal strip per wiring schematic.
  • Verify Manual/Auto selector is set to Auto before enabling remote SCADA switching.
  • Compare with modular VM6EY et DC6.

FAQ

What does ‘four-remote’ mean on VM6EY-MP3/JLY?

Four-remote refers to telemetry (live current/voltage/power), tele-signaling (breaker status & fault alarms), tele-control (remote open/close ≤1 s), and tele-adjustment (remote trip setting updates).

What frame sizes are available?

VM6EY-250MP3/JLY (50–250 A) and VM6EY-630MP3/JLY (160–630 A).

What is the breaking capacity and Icw?

50 kA Icu (35 kA Ics on 250 A; 50 kA Ics on 630 A) and 10 kA/1s Icw at AC 400 V.

How fast is the motorized response time?

≤1 second for both opening and closing.

Does it include electrical metering?

Yes. Real-time electrical measurement is built directly into the breaker.

Can it be switched manually if control power fails?

Yes. The front Manual/Auto switch allows safe local manual operation.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Besoin d'un devis produit ?
Construisons-le ensemble.

Envoyez-nous le modèle du produit, les caractéristiques techniques, la quantité et les exigences OEM. Notre équipe examinera votre demande et vous répondra dans un délai d'un jour ouvré.

Demander un Devis