VIOX ELECTRIC
Langue

VIOX ECB Series Cost-Control & Utility Molded Case Circuit Breaker (160A–1600A)

VIOX ECB Series 3-Pole Cost-Control Molded Case Circuit Breaker (160 A–1600 A, AC 230/400 V, Ui 1000 V, Uimp 8 kV, Class B, up to 100 kA Icu / 85 kA Ics) is built for Middle East and utility metering enclosures with integrated cost-control switching, heavy-duty terminal posts, padlocking, and protective covers.

Frame Range
160–1600 A (6 Frames · 3P)
Max Breaking (400V)
Up to 100 kA Icu / 85 kA Ics
Utility Hardware
Terminal Posts · Padlock · Cover
Category & Ui
Class B · Ui 1000 V / Uimp 8 kV

Vue d'ensemble

The VIOX ECB Series is a heavy-duty 3-pole cost-control molded case circuit breaker tailored for utility metering enclosures, commercial prepaid distribution, and Middle East grid specifications. Covering 6 frames from 160 A to 1600 A (16 A–1600 A, AC 230/400 V, Ui 1000 V, Uimp 8 kV, Class B), ECB integrates cost-control disconnect functionality, extended terminal posts, tamper-evident padlocking, and protective terminal covers—with breaking capacity reaching 100 kA Icu / 85 kA Ics on ECB-1600.

Caractéristiques

  • Engineered for utility metering and Middle East distribution board requirements.
  • 6 three-pole frames: ECB-160, 250, 400/630, 800, 1250, and 1600 A (16 A–1600 A).
  • High breaking capacity: 100% Ics = Icu (20–40 kA) from 160 A to 1250 A, and 100 kA Icu / 85 kA Ics on ECB-1600 at AC 400 V.
  • Integrated cost-control switching, extended terminal posts, padlocking provision, and protective terminal covers.
  • Utilization Category Class B with Ui = 1000 V and Uimp = 8 kV per IEC/EN 60947-2.
  • Up to 10,000 mechanical cycles (with maintenance) on 160–250 A frames.

Modèles

ModèleRated Current In (A)PôlesIcu / Ics (400 V)Dimensions W×L×H (mm)
ECB-16016–160 A3P20 kA / 20 kA155 × 90 × 117
ECB-250100–250 A3P20 kA / 20 kA208 × 105 × 115
ECB-400/630250–400 A · 400–630 A3P20 kA / 20 kA337 × 168 × 155
ECB-800500–800 A3P40 kA / 40 kA418 × 238 × 168
ECB-12501000–1250 A3P40 kA / 40 kA418 × 238 × 168
ECB-16001250–1600 A3P100 kA / 85 kA210 × 340 × 229

Spécifications

Electrical & Endurance Data (3P, AC 230/400 V)

ModèleIcu / Ics (230 V)Icu / Ics (400 V)Durée de vie électriqueMech. Life (Maint-Free / w/ Maint)
ECB-16025 / 25 kA20 / 20 kA1,0007,000 / 10,000
ECB-25025 / 25 kA20 / 20 kA1,0007,000 / 10,000
ECB-400/63025 / 25 kA20 / 20 kA1,0004,000 / 7,000
ECB-80065 / 65 kA40 / 40 kA5002,500 / 5,000
ECB-125065 / 65 kA40 / 40 kA5002,500 / 3,500
ECB-160075 / 65 kA100 / 85 kA5002,500 / 3,500

Guide de sélection

Position du codeSignificationCatalog Value or Options
ECBSérie3P Cost-control & utility molded case circuit breaker
160–1600Courant de châssis160, 250, 400/630, 800, 1250, 1600 A
3PPôlesThree-pole utility configuration with terminal posts & protective cover

1. Meet Utility Specs

Specify ECB for Middle East and regional utility enclosures requiring terminal posts and padlockable covers.

2. Verify 100% Ics = Icu

160–1250 A frames offer Ics = 100% Icu; ECB-1600 scales to 100 kA Icu / 85 kA Ics.

3. Integrate Cost Control

Connect smart-meter disconnect signals for remote utility billing enforcement.

4. Check Enclosure Cutout

Review exact W × L × H dimensions including protective terminal covers.

Installation

  • Secure the included protective terminal covers and utility seal/padlock after cable termination.
  • Verify torque on extended terminal posts before energizing high-current 800–1600 A feeders.
  • Explore the complete VIOX MCCB portfolio for standard IEC 60947-2 panels.

FAQ

What makes ECB different from standard VM6 MCCBs?

ECB is purpose-built for utility and Middle East metering enclosures, adding integrated cost-control disconnect functionality, extended terminal posts, padlocking provisions, and protective terminal covers.

What current range does ECB cover?

Six 3-pole frames from 160 A to 1600 A covering rated currents from 16 A through 1600 A.

What is the breaking capacity of ECB at 400 V AC?

20 kA Icu/Ics on 160–630 A, 40 kA Icu/Ics on 800–1250 A, and 100 kA Icu / 85 kA Ics on ECB-1600.

Are protective terminal covers and locks included?

Yes. ECB is designed with terminal posts, lock provision, and protective covers for tamper-resistant utility installations.

What utilization category is ECB?

Utilization Category Class B with Ui = 1000 V and Uimp = 8 kV.

Can VIOX supply ECB with custom utility markings?

Yes. VIOX supports OEM/utility specification markings and export documentation.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Besoin d'un devis produit ?
Construisons-le ensemble.

Envoyez-nous le modèle du produit, les caractéristiques techniques, la quantité et les exigences OEM. Notre équipe examinera votre demande et vous répondra dans un délai d'un jour ouvré.

Demander un Devis