VIOX VM6EY-MP3/JLY Series Intelligent Four-Remote MCCB (250A–630A)

VIOX VM6EY-MP3/JLY Series Intelligent Four-Remote Circuit Breaker (250 A and 630 A frames; 50 A–630 A adjustable; AC 400 V; 50 kA Icu; Icw 10 kA/1s) unites an electronic metering MCCB with a factory-integrated DC6 rapid actuator (≤1 s response) for complete telemetry, tele-signaling, tele-control, and tele-adjustment.

Frame Range
250 A & 630 A (50–630 A)
Reaktionsgeschwindigkeit
Four-Remote Quick Action ≤ 1 s
Breaking & Icw
50 kA Icu · 35–50 kA Ics · 10 kA/1s
Integration
Built-in Metering + DC6 Actuator

Übersicht

The VIOX VM6EY-MP3/JLY Series is a factory-integrated intelligent four-remote molded case circuit breaker combining an electronic Class B metering MCCB with a built-in DC6 rapid electric actuator. Covering 250 A (50–250 A) and 630 A (160–630 A) frames at AC 400 V (Ui 1000 V, Uimp 8 kV, 50 kA Icu, Icw 10 kA/1s), VM6EY-MP3/JLY delivers ≤1 s remote switching, high-precision electrical measurement, and plug-and-play SCADA connectivity in one compact unit.

Eigenschaften

  • Complete four-remote capability (telemetry, tele-signaling, tele-control, tele-adjustment) in one integrated unit.
  • Ultra-fast ≤1 s remote opening and closing response via factory-matched DC6 actuator.
  • 50 kA Icu breaking capacity (35 kA Ics on 250 A; 50 kA Ics on 630 A) and 10 kA/1s short-time withstand (Icw).
  • Integrated electrical measurement function with front LCD settings and ON/TRIPPED/OFF status.
  • Compact single-body installation reduces panel wiring and commissioning time.
  • Rated Ui = 1000 V, Uimp = 8 kV, AC 400 V 50/60 Hz.

Modelle

ModellAdjustable Rated Current In (A)Ue / Ui / UimpIcu / Ics (400 V)Icw & Response
VM6EY-250MP3/JLY125 A (50–125 A) · 250 A (100–250 A)AC 400 V / 1000 V / 8 kV50 kA / 35 kA10 kA/1s · ≤ 1 s
VM6EY-630MP3/JLY400 A (160–400 A) · 630 A (252–630 A)AC 400 V / 1000 V / 8 kV50 kA / 50 kA10 kA/1s · ≤ 1 s

Spezifikationen

Electrical & Control Specifications

ParameterVM6EY-250MP3/JLYVM6EY-630MP3/JLY
Rated working voltage UeAC 400 VAC 400 V
Rated insulation / UimpAC 1000 V / 8 kVAC 1000 V / 8 kV
Rated short-time withstand Icw10 kA / 1 s10 kA / 1 s
Breaking capacity Icu / Ics50 kA / 35 kA50 kA / 50 kA
Operation quick response time≤ 1 s≤ 1 s

Auswahlhilfe

CodepositionBedeutungCatalog Value or Options
VM6EYSerieElectronic LCD metering MCCB platform
250 / 630Rahmenstrom250 A (50–250 A) or 630 A (160–630 A)
MP3/JLYIntegrated packageFactory-integrated DC6 rapid actuator + four-remote metering module

1. Deploy Turnkey Four-Remote

Order VM6EY-MP3/JLY when you want breaker, metering, and motorized drive pre-assembled and factory-tested.

2. Verify ≤1 s Actuation

Rapid opening/closing supports automated feeder transfer and demand-response load shedding.

3. Match Fault Capacity

50 kA Icu and 10 kA/1s Icw fit commercial and utility substation feeders.

4. Connect RS485/SCADA

Wire L/N/A/B/S2/S4 bottom terminals directly to your RTU or EMS gateway.

Einrichtung

  • Connect control power and RS485 A/B terminals on the bottom terminal strip per wiring schematic.
  • Verify Manual/Auto selector is set to Auto before enabling remote SCADA switching.
  • Compare with modular VM6EY und DC6.

FAQ

What does ‘four-remote’ mean on VM6EY-MP3/JLY?

Four-remote refers to telemetry (live current/voltage/power), tele-signaling (breaker status & fault alarms), tele-control (remote open/close ≤1 s), and tele-adjustment (remote trip setting updates).

What frame sizes are available?

VM6EY-250MP3/JLY (50–250 A) and VM6EY-630MP3/JLY (160–630 A).

What is the breaking capacity and Icw?

50 kA Icu (35 kA Ics on 250 A; 50 kA Ics on 630 A) and 10 kA/1s Icw at AC 400 V.

How fast is the motorized response time?

≤1 second for both opening and closing.

Does it include electrical metering?

Yes. Real-time electrical measurement is built directly into the breaker.

Can it be switched manually if control power fails?

Yes. The front Manual/Auto switch allows safe local manual operation.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Benötigen Sie ein Produktangebot?
Lassen Sie es uns gemeinsam aufbauen.

Senden Sie uns das Produktmodell, die technischen Nennwerte, die Menge und die OEM-Anforderungen. Unser Team wird Ihre Anwendung prüfen und innerhalb eines Werktages antworten.

Angebot anfordern