VIOX FCT18-Ata Pulse Delayed Timer Relay with Summation Control Signal

The VIOX FCT18-Ata Pulse Delayed Timer Relay offers precise ON-delay timing (0.1s-100 days) with summation of NPN/PNP control signal pulses. Features <0.5% error, 1 or 2 SPDT contacts, DIN rail mount, and supports AC/DC 12-240V, Ideal for automation and process control requiring pulse accumulation.

Send your requirements, we will quote for you within 12 hours​

Product Overview

The VIOX FCT18-Ata is an advanced pulse delayed timer relay designed for precise timing control in industrial automation, process control, and electrical systems. With its ON-delay function and summation control signal capability, this timer relay provides exceptional accuracy and reliability for applications requiring precise timing sequences. The FCT18-Ata stands out with its wide time range settings from 0.1 seconds to 100 days, broad power supply compatibility, and industry-leading accuracy.

Key Features and Benefits

  • Versatile Timing Range: Exceptional flexibility with timing ranges from 0.1 seconds to 100 days, suitable for both ultra-short and extended timing applications
  • ON-Delay Function with Summation Control: Advanced timing function that sums multiple input pulses (t1 + t2 + … + tx) for precise process control
  • Wide Power Supply Range: Compatible with 12 to 240 VAC/DC power supplies, making it versatile for various global installation requirements
  • High Precision: Time error less than 0.5% and time deviation of only 0.1%, ensuring reliable and consistent operation
  • Strong Anti-Interference Capability: Built to withstand electromagnetic interference in industrial environments
  • Easy Setup: Intuitive configuration with convenient wiring diagrams printed on the device
  • DIN Rail Mounting: Standard DIN rail EN/IEC 60715 mounting for easy installation in control cabinets
  • LED Status Indicators: Green LED for power supply indication and red LED for relay status
  • IP20 Protection: Suitable for indoor industrial environments
  • International Compliance: Meets GB/T 14048.5, IEC60947-5-1, EN6812-1 standards

Understanding the FCT18-Ata Timing Function

The FCT18-Ata features an ON-delay timing function with pulse summation capability, making it ideal for applications requiring cumulative timing:

Ata: ON-delay with Summation Control

VIOX FCT18-Ata Pulse Delayed Timer Relay timing function

When the control input (S) receives pulses, the timer accumulates the duration of all valid pulses. The timing diagram illustrates how multiple input signals (t1, t2, t3, …, tx) are summed together, with the output relay (R) activating when the total accumulated time (T = t1 + t2 + … + tx) is reached. This feature is particularly valuable in processes where multiple events need to trigger a response based on their cumulative duration.

Time Setting Options

The FCT18-Ata offers unparalleled flexibility with its comprehensive time range settings:

VIOX FCT18-Ata Pulse Delayed Timer Relay time setting

Range Description Typical Applications
0.1-1s Ultra-short timing range in tenths of seconds High-speed manufacturing, rapid response safety systems
1-10s Short timing range in seconds Process control, conveyor systems, light sequencing
0.1-1m Timing in tenths of minutes Material handling, basic industrial processes
1-10m Timing in minutes Machine cycles, cooling systems, heating processes
0.1-1hr Timing in tenths of hours Extended processing, environmental control systems
1-10hr Timing in hours Long-duration industrial processes, extended cycles
0.1-1day Timing in tenths of days Daily manufacturing cycles, daily maintenance
1-10day Timing in days Extended industrial processes, multi-day cycles
3-30day Extended timing in months Long-term monitoring, scheduled maintenance
10-100day Maximum duration timing Seasonal operations, long-term processing

Ratio Setting Options

Fine-tune your timing precision with 18 ratio settings from 10% to 100%, allowing precise calibration of the timing function:

VIOX FCT18-Ata Pulse Delayed Timer Relay ratio setting

Ratio Settings Application
10%, 15%, 20%, 25% Low-range precision timing for delicate processes
30%, 35%, 40%, 45%, 50%, 55% Mid-range timing for standard industrial applications
60%, 65%, 70%, 75%, 80%, 85%, 90%, 95%, 100% High-range timing for extended duration processes

Wiring Options

The FCT18-Ata supports both NPN and PNP control signal configurations, offering versatile integration options:

VIOX FCT18-Ata Pulse Delayed Timer Relay wiring

  • NPN Configuration: Suitable for sinking current applications
  • PNP Configuration: Suitable for sourcing current applications

The relay features dedicated terminals for power supply (Un), control signal (S), and output contacts (OA1, OA2).

Dimension

VIOX FCT18-Ata Pulse Delayed Timer Relay dimension

Model Selection Guide

The FCT18-Ata is available in multiple configurations, following the model code system: FCT18-Ata1_W_N

Position Code Description
1. Function Ata ON-delay with summation control
2. Type of output 1 1CO contact (1 changeover contact)
2 2CO contacts (2 changeover contacts)
3. Supply voltage A AC 230V
D DC 24V
W AC/DC 12-240V
4. Control signal N NPN
P PNP

Technical Specifications

Parameter FCT18-Ata1 FCT18-Ata2
Input Terminal A1-A2 A1-A2
Voltage range AC 230V / DC 24V / AC/DC 12-240V
Power consumption AC 3.5VA/ DC 2.0W
Voltage tolerance -15% ~ +10%
Supply indication Green LED
Relay indication Red LED
Time ranges 0.1s-100days
Time setting Button
Time deviation 0.1%
Repeat accuracy 0.5%
Temperature coefficient 0.05%/°C, at=20°C (0.05%/°F, at=68°F)
Output contact 1*SPDT 2*SPDT
Rated current 1*16A 2*16A
Mechanical life 1*10⁷
Electrical life 1*10⁵
Ambient Temperature -20 … +60 °C / -40 … +85 °C
Mounting DIN rail EN/IEC 60715
IP Rating IP20
Stripping length 7mm (0.28in)
Installed altitude ≤2200m
Pollution level 2
Max cable size AWG13-20 0.4N·m
Dimension 90mm*18mm*64mm
Weight about 90g
Standards GB/T 14048.5, IEC60947-5-1, EN6812-1

Applications of FCT18-Ata Pulse Delayed Timer Relay

The FCT18-Ata is exceptionally versatile and can be utilized in numerous industrial and commercial applications:

Industrial Automation

  • Sequential Process Control: Time-based activation of multiple process steps in manufacturing lines
  • Conveyor Systems: Controlling start/stop timing and synchronization between different conveyor sections
  • Packaging Machinery: Precise timing for folding, sealing, and cutting operations
  • Material Handling Equipment: Controlled movement sequences with precise timing intervals

Building Automation

  • HVAC Systems: Timed control of heating, ventilation, and air conditioning cycles
  • Lighting Control: Advanced timing for public area lighting, including stairwells and corridors
  • Security Systems: Timed delay for access control and alarm integration
  • Pump Control: Timed operation of water pumps and irrigation systems

Energy Management

  • Generator Systems: Controlled startup and shutdown sequences
  • Power Distribution: Timed switching between power sources
  • Load Shedding: Sequential disconnection of non-critical loads
  • Energy Conservation: Timed operation of equipment to minimize energy consumption

Process Industries

  • Chemical Processing: Precise timing for mixing and reaction processes
  • Food & Beverage: Control of processing times for consistent product quality
  • Pharmaceutical: Precise timing for sterilization and production processes
  • Water Treatment: Controlled cycle times for filtration and treatment processes

Installation and Setup Guide

Installing and configuring the FCT18-Ata is straightforward:

Installation Steps

  1. Mount the relay on a standard DIN rail in your control cabinet
  2. Connect power supply to terminals A1 and A2
  3. Wire the control signal (S) according to your NPN or PNP configuration
  4. Connect output devices to the appropriate output terminals (11-14, 21-24 for dual output model)
  5. Set the desired time range using the rotary selector
  6. Fine-tune the timing ratio using the percentage dial
  7. Apply power and verify operation with the LED indicators

Wiring Precautions

  • Ensure proper voltage levels according to specifications
  • Use wire sizes not exceeding AWG13-20
  • Maintain proper stripping length of 7mm (0.28in)
  • Follow the correct NPN or PNP wiring diagram as indicated on the product
  • Ensure environmental conditions meet the IP20 rating requirements

Troubleshooting Guide

Common issues and solutions for the FCT18-Ata timer relay:

Issue Possible Cause Solution
Relay does not activate No power supply Check power connections and voltage level
Green LED not illuminated Power supply issue Verify power supply is within -15% to +10% tolerance
Timing function not working Incorrect signal connection Verify correct NPN/PNP wiring configuration
Inconsistent timing Environmental interference Ensure proper installation away from high EMI sources
Relay activates too early/late Incorrect time/ratio setting Adjust time range and ratio settings according to requirements
Invalid signal detection Signal outside specification Verify control signal meets the device requirements

Why Choose VIOX FCT18-Ata Pulse Delayed Timer Relay?

The FCT18-Ata stands out from competitors with its exceptional combination of features and benefits:

  • Unmatched Versatility: With time ranges from 0.1 seconds to 100 days, this single device can replace multiple specialized timers
  • Superior Accuracy: Time error less than 0.5% and time deviation of only 0.1% ensures precise and reliable operation
  • Universal Compatibility: Wide power supply range (12-240 VAC/DC) makes it suitable for global applications
  • Industrial Robustness: Operating temperature range of -20°C to +60°C with strong anti-interference capability ensures reliable performance in harsh environments
  • Space-Efficient Design: Compact dimensions (90mm*18mm*64mm) allow for efficient use of control cabinet space
  • Long Service Life: Mechanical durability of 10 million operations and electrical durability of 100,000 operations at rated load
  • Clear Visual Indication: Dual LED indicators for power supply (green) and relay status (red)
  • International Compliance: Meets relevant global standards for industrial control equipment

Conclusion

The VIOX FCT18-Ata pulse delayed timer relay with summation control signal represents the pinnacle of timing relay technology. Its exceptional versatility, precision, and reliability make it the ideal choice for industrial automation, building management, energy control, and process industries. With its comprehensive range of timing options, dual contact configurations, and universal power supply compatibility, the FCT18-Ata provides a single-device solution for virtually any timing control application.

By choosing the FCT18-Ata, you’re investing in a product engineered to deliver consistent performance, reduce installation complexity, and enhance the reliability of your control systems. Contact VIOX today to discover how the FCT18-Ata can optimize your timing control applications and elevate your operational efficiency.

Related Products

Ask for Quote Now

Ask for Quote Now