VIOX ELECTRIC
ພາສາ

ຄອນແທັກເຕີ AC 4 ຂົ້ວ VIOX CJX2s-4P

Four-pole AC contactors with selectable main-contact
ການຕັ້ງຄ່າ.

  • 9–95 A AC-3 at 380/400 V
  • 04: 4NO; 08: 2NO + 2NC main contacts
  • 690 V ລະດັບແຮງດັນສນວນ
  • AC coil options; rail or screw mounting

ພາບລວມ

VIOX CJX2s-4P AC contactors provide four-pole switching with
model-specific AC-3 ratings from 9 to 95 A at 380/400 V. The series
offers 04 and 08 main-contact configurations for different circuit
arrangements, with rail or screw mounting.

ຄຸນສົມບັດ

  • Four main poles with 4NO or 2NO + 2NC configurations.
  • Engineering-plastic base and integrated product marking.
  • Mounting slider for installation and removal.
  • Terminal covers and optional transparent front dust cover.

Contact Configurations

Suffix Main-contact arrangement
04 Four normally open contacts (4NO)
08 Two normally open and two normally closed contacts (2NO + 2NC)

These suffixes describe the main contacts, not auxiliary contacts.
Select the arrangement to match the circuit: 08 is not equivalent to
four normally open poles. A contactor alone is not a complete automatic
transfer-switch system.

ຂໍ້ມູນຈໍາເພາະ

Frame/model designation (4P) ກະແສ AC-3 ທີ່ 380/400 V ກຳລັງມໍເຕີ AC-3 ທີ່ 380/400 V
CJX2s-09 9 A 4 kW
CJX2s-12 12 A 5.5 kW
CJX2s-18 18 A 7.5 kW
CJX2s-25 25 A 11 kW
CJX2s-32 32 A 15 kW
CJX2s-38 38 A 18.5 kW
CJX2s-40 40 A 18.5 kW
CJX2s-50 50 A 22 kW
CJX2s-65 65 A 30 kW
CJX2s-80 80 A 37 kW
CJX2s-95 95 A 45 kW

Complete the model selection with the required 04 or 08 contact
configuration and coil voltage. Ratings above apply to AC-3 at 380/400
V; other operating voltages and utilization categories have different
ratings.

ພາລາມິເຕີ ຂໍ້ມູນຈໍາເພາະ
ຂົ້ວຫຼັກ ໔P
ລະດັບແຮງດັນຂອງ insulation Ui 690 V
Main-circuit voltages in the rating table 380/400 V; 660/690 V
AC coil voltage options 24, 36, 48, 110, 127, 220/230, 240, 380/400, 415, 440 V
ທາງເລືອກຄວາມຖີ່ຂອງຄອຍ 50 Hz; 50/60 Hz
Coil operation range, frames 09–38 70%–120% Us
Coil operation range, frames 40–95 90%–120% Us
Protection, frames 09–38 IP20, ບໍ່ລວມຂົ້ວຕໍ່
Protection, frames 40–95 IP10
ປະເພດການຕິດຕັ້ງ III
ລະດັບມົນລະພິດ 3
ການຕິດຕັ້ງ ราง ຫຼື ສະກູ

ຂະໜາດ

The drawings distinguish frames 09–38 and 40–95. For frames 40–95,
the 04 and 08 configurations have different Cmax dimensions; check the
exact configuration before allocating mounting space.

CJX2s-4P contactor installation dimensions for 04 and 08 configurations

ຂໍ້ມູນການສັ່ງຊື້

Provide the current/frame designation, 04 or 08 contact arrangement,
load voltage and utilization category, coil voltage and frequency,
ອຸປະກອນເສີມ ແລະ ຈໍານວນເມື່ອຮ້ອງຂໍໃບສະເໜີລາຄາ.

ຕ້ອງການໃບສະເໜີລາຄາສິນຄ້າບໍ?
ມາສ້າງສັນໄປພ້ອມກັນ.

ສົ່ງຮຸ່ນສິນຄ້າ, ຄ່າທາງເຕັກນິກ, ຈຳນວນ ແລະ ຄວາມຕ້ອງການ OEM ໃຫ້ພວກເຮົາ. ທີມງານຂອງພວກເຮົາຈະກວດສອບການນຳໃຊ້ຂອງທ່ານ ແລະ ຕອບກັບພາຍໃນໜຶ່ງມື້ເຮັດວຽກ.