VIOX ELECTRIC
زبان

VIOX CJX2s-4P چار پول والا AC کونٹیکٹر

Four-pole AC contactors with selectable main-contact
تشکیلات۔.

  • 9–95 A AC-3 at 380/400 V
  • 04: 4NO; 08: 2NO + 2NC main contacts
  • 690 V ریٹڈ انسولیشن وولٹیج
  • AC coil options; rail or screw mounting

جائزہ

VIOX CJX2s-4P AC contactors provide four-pole switching with
model-specific AC-3 ratings from 9 to 95 A at 380/400 V. The series
offers 04 and 08 main-contact configurations for different circuit
arrangements, with rail or screw mounting.

خصوصیات

  • Four main poles with 4NO or 2NO + 2NC configurations.
  • Engineering-plastic base and integrated product marking.
  • Mounting slider for installation and removal.
  • Terminal covers and optional transparent front dust cover.

Contact Configurations

Suffix Main-contact arrangement
04 Four normally open contacts (4NO)
08 Two normally open and two normally closed contacts (2NO + 2NC)

These suffixes describe the main contacts, not auxiliary contacts.
Select the arrangement to match the circuit: 08 is not equivalent to
four normally open poles. A contactor alone is not a complete automatic
transfer-switch system.

تکنیکی وضاحتیں

Frame/model designation (4P) 380/400 V پر AC-3 کرنٹ 380/400 V پر AC-3 موٹر پاور
CJX2s-09 9 A 4 kW
CJX2s-12 12 A 5.5 kW
CJX2s-18 18 A 7.5 kW
CJX2s-25 25 A 11 کلو واٹ
CJX2s-32 32 A 15 kW
CJX2s-38 38 A 18.5 kW
CJX2s-40 40 A 18.5 kW
CJX2s-50 50 A 22 کلو واٹ
CJX2s-65 65 A 30 kW
CJX2s-80 80 A 37 kW
CJX2s-95 95 A 45 kW

Complete the model selection with the required 04 or 08 contact
configuration and coil voltage. Ratings above apply to AC-3 at 380/400
V; other operating voltages and utilization categories have different
ratings.

پیرامیٹر تفصیلات
مین پولز 4P
شرح شدہ موصلیت وولٹیج Ui 690 V
Main-circuit voltages in the rating table 380/400 V; 660/690 V
AC coil voltage options 24, 36, 48, 110, 127, 220/230, 240, 380/400, 415, 440 V
کوائل فریکوئنسی کے اختیارات 50 Hz; 50/60 Hz
Coil operation range, frames 09–38 70%–120% Us
Coil operation range, frames 40–95 90%–120% Us
Protection, frames 09–38 IP20، ٹرمینلز کے علاوہ
Protection, frames 40–95 آئی پی 10
تنصیب کا زمرہ III
آلودگی کی ڈگری 3
چڑھنا ریل یا سکرو

طول و عرض

The drawings distinguish frames 09–38 and 40–95. For frames 40–95,
the 04 and 08 configurations have different Cmax dimensions; check the
exact configuration before allocating mounting space.

CJX2s-4P contactor installation dimensions for 04 and 08 configurations

آرڈرنگ کی معلومات

Provide the current/frame designation, 04 or 08 contact arrangement,
load voltage and utilization category, coil voltage and frequency,
لوازمات اور مقدار کو کوٹیشن کی درخواست کرتے وقت بتائیں۔.

پروڈکٹ کا کوٹیشن درکار ہے؟
آئیے مل کر اسے تعمیر کریں۔.

ہمیں پروڈکٹ ماڈل، تکنیکی ریٹنگز، مقدار، اور OEM ضروریات بھیجیں۔ ہماری ٹیم آپ کی درخواست کا جائزہ لے گی اور ایک کاروباری دن کے اندر جواب دے گی۔.

ایک اقتباس کی درخواست کریں۔