VIOX ELECTRIC
ভাষা

VIOX CJX2s-4P ফোর-পোল AC কন্টাক্টর

Four-pole AC contactors with selectable main-contact
কনফিগারেশন।.

  • 9–95 A AC-3 at 380/400 V
  • 04: 4NO; 08: 2NO + 2NC main contacts
  • 690 V rated insulation voltage
  • AC coil options; rail or screw mounting

সংক্ষিপ্ত বিবরণ

VIOX CJX2s-4P AC contactors provide four-pole switching with
model-specific AC-3 ratings from 9 to 95 A at 380/400 V. The series
offers 04 and 08 main-contact configurations for different circuit
arrangements, with rail or screw mounting.

ফিচার

  • Four main poles with 4NO or 2NO + 2NC configurations.
  • Engineering-plastic base and integrated product marking.
  • Mounting slider for installation and removal.
  • Terminal covers and optional transparent front dust cover.

Contact Configurations

Suffix Main-contact arrangement
04 Four normally open contacts (4NO)
08 Two normally open and two normally closed contacts (2NO + 2NC)

These suffixes describe the main contacts, not auxiliary contacts.
Select the arrangement to match the circuit: 08 is not equivalent to
four normally open poles. A contactor alone is not a complete automatic
transfer-switch system.

কারিগরি বিবরণ

Frame/model designation (4P) AC-3 current at 380/400 V 380/400 V এ AC-3 মোটর পাওয়ার
CJX2s-09 9 A 4 kW
CJX2s-12 12 A 5.5 kW
CJX2s-18 18 A 7.5 kW
CJX2s-25 ২৫ এ 11 কিলোওয়াট
CJX2s-32 ৩২ A 15 kW
CJX2s-38 38 A 18.5 kW
CJX2s-৪০ ৪০ A 18.5 kW
CJX2s-৫০ 50 A 22 কিলোওয়াট
CJX2s-৬৫ 65 A 30 kW
CJX2s-৮০ 80 A 37 kW
CJX2s-95 ৯৫ A 45 kW

Complete the model selection with the required 04 or 08 contact
configuration and coil voltage. Ratings above apply to AC-3 at 380/400
V; other operating voltages and utilization categories have different
ratings.

প্যারামিটার স্পেসিফিকেশন
প্রধান পোল ৪পি
রেটেড ইনসুলেশন ভোল্টেজ Ui 690 V
Main-circuit voltages in the rating table 380/400 V; 660/690 V
AC coil voltage options 24, 36, 48, 110, 127, 220/230, 240, 380/400, 415, 440 V
Coil frequency options 50 Hz; 50/60 Hz
Coil operation range, frames 09–38 70%–120% Us
Coil operation range, frames 40–95 90%–120% Us
Protection, frames 09–38 IP20, টার্মিনাল ব্যতীত
Protection, frames 40–95 IP10
ইনস্টলেশন বিভাগ তৃতীয়
দূষণ ডিগ্রী 3
মাউন্টিং রেল বা স্ক্রু

মাত্রা

The drawings distinguish frames 09–38 and 40–95. For frames 40–95,
the 04 and 08 configurations have different Cmax dimensions; check the
exact configuration before allocating mounting space.

CJX2s-4P contactor installation dimensions for 04 and 08 configurations

অর্ডার তথ্য

Provide the current/frame designation, 04 or 08 contact arrangement,
load voltage and utilization category, coil voltage and frequency,
অ্যাক্সেসরিজ এবং পরিমাণ উল্লেখ করুন যখন একটি কোটেশনের জন্য অনুরোধ করা হচ্ছে।.

পণ্যের কোটেশন প্রয়োজন?
আসুন একসাথে এটি তৈরি করি।.

আমাদের কাছে পণ্যের মডেল, প্রযুক্তিগত রেটিং, পরিমাণ এবং OEM প্রয়োজনীয়তা পাঠান। আমাদের টিম আপনার অ্যাপ্লিকেশন পর্যালোচনা করবে এবং এক কর্মদিবসের মধ্যে উত্তর দেবে।.

উদ্ধৃতির জন্য আবেদন