VIOX ELECTRIC
اللغة

كونتاكتور AC رباعي الأقطاب VIOX CJX2s-4P

Four-pole AC contactors with selectable main-contact
التكوينات.

  • 9–95 A AC-3 at 380/400 V
  • 04: 4NO; 08: 2NO + 2NC main contacts
  • جهد عزل مقنن 690 V
  • AC coil options; rail or screw mounting

نظرة عامة

VIOX CJX2s-4P AC contactors provide four-pole switching with
model-specific AC-3 ratings from 9 to 95 A at 380/400 V. The series
offers 04 and 08 main-contact configurations for different circuit
arrangements, with rail or screw mounting.

الميزات

  • Four main poles with 4NO or 2NO + 2NC configurations.
  • Engineering-plastic base and integrated product marking.
  • Mounting slider for installation and removal.
  • Terminal covers and optional transparent front dust cover.

Contact Configurations

Suffix Main-contact arrangement
04 Four normally open contacts (4NO)
08 Two normally open and two normally closed contacts (2NO + 2NC)

These suffixes describe the main contacts, not auxiliary contacts.
Select the arrangement to match the circuit: 08 is not equivalent to
four normally open poles. A contactor alone is not a complete automatic
transfer-switch system.

المواصفات الفنية

Frame/model designation (4P) تيار AC-3 عند 380/400 V قدرة محرك AC-3 عند 380/400 V
CJX2s-09 9 A 4 kW
CJX2s-12 12 A 5.5 kW
CJX2s-18 21.6 أمبير 7.5 kW
CJX2s-25 25 أمبير 11 كيلوواط
CJX2s-32 32 أمبير 15 kW
CJX2s-38 38 A 18.5 kW
CJX2s-40 40 أمبير 18.5 kW
CJX2s-50 50 أمبير 22 كيلوواط
CJX2s-65 65 A 30 kW
CJX2s-80 80 A 37 kW
CJX2s-95 95 أمبير 45 kW

Complete the model selection with the required 04 or 08 contact
configuration and coil voltage. Ratings above apply to AC-3 at 380/400
V; other operating voltages and utilization categories have different
ratings.

المعلمة المواصفات
الأقطاب الرئيسية 4P
جهد العزل المقدر Ui 690 V
Main-circuit voltages in the rating table 380/400 V؛ 660/690 V
AC coil voltage options 24, 36, 48, 110, 127, 220/230, 240, 380/400, 415, 440 V
خيارات تردد الملف 50 Hz؛ 50/60 Hz
Coil operation range, frames 09–38 70%–120% Us
Coil operation range, frames 40–95 90%–120% Us
Protection, frames 09–38 IP20، باستثناء أطراف التوصيل
Protection, frames 40–95 IP10
فئة التركيب ثالثاً
درجة التلوث 3
التركيب سكك حديدية أو برغي

البعد

The drawings distinguish frames 09–38 and 40–95. For frames 40–95,
the 04 and 08 configurations have different Cmax dimensions; check the
exact configuration before allocating mounting space.

CJX2s-4P contactor installation dimensions for 04 and 08 configurations

معلومات الطلب

Provide the current/frame designation, 04 or 08 contact arrangement,
load voltage and utilization category, coil voltage and frequency,
الملحقات والكمية عند طلب عرض أسعار.

هل تحتاج إلى عرض سعر للمنتج؟
لنبنيها معاً.

أرسل لنا طراز المنتج، والتقييمات الفنية، والكمية، ومتطلبات الشركة المصنعة للمعدات الأصلية (OEM). سيقوم فريقنا بمراجعة طلبك والرد في غضون يوم عمل واحد.

طلب عرض أسعار