VIOX ELECTRIC
Lingua

VIOX VSP-T15/B+C AC Type 1+2+3 Combined Surge Protection Device (Iimp 12.5kA)

The VIOX VSP-T15/B+C is an all-in-one Type 1 + Type 2 + Type 3 (T1+T2+T3) AC lightning current and surge arrester housed in a high-strength black industrial enclosure. Delivering Iimp 6.25 kA, 8 kA, or 12.5 kA (10/350 μs) per pole and Uoc 20 kV (Type 3) with ultra-low Up 1.25 kV clamping, it protects main incoming panels against both direct lightning strikes and switching transients in a compact 18 mm-per-pole footprint.

Serie VIOX
VSP-T15/B+C
Tensione nominale
AC 275V (L-N) / 255V (N-PE)
Surge Rating
Iimp 6.25 / 8 / 12.5 kA (10/350μs)
Standard
IEC 61643-11 · T1+T2+T3 · CE / CB

Panoramica

The VIOX VSP-T15/B+C is an all-in-one Type 1 + Type 2 + Type 3 (T1+T2+T3) AC lightning current and surge arrester housed in a high-strength black industrial enclosure. Delivering Iimp 6.25 kA, 8 kA, or 12.5 kA (10/350 μs) per pole and Uoc 20 kV (Type 3) with ultra-low Up 1.25 kV clamping, it protects main incoming panels against both direct lightning strikes and switching transients in a compact 18 mm-per-pole footprint.

Caratteristiche

  • True T1+T2+T3 combined arrester: handles 10/350 μs lightning current (Iimp 6.25 / 8 / 12.5 kA L-N; 25 kA N-PE) and 20 kV Type 3 combination wave.
  • Ultra-low voltage protection level Up 1.25 kV (L-N) and 1.5 kV (N-PE) protects sensitive downstream electronics without requiring a separate T2 stage.
  • Zero follow-current / leakage-free N-PE GDT path (Ipe = NONE) with 25,000 A short-circuit rating (Isccr).
  • Compact 18 mm/pole modular width (1P, 1+NPE, 2P, 3P, 4P, 3+NPE) with built-in thermal disconnector and remote signaling contacts.

Specifiche tecniche

VSP-T15/B+C Electrical & Mechanical Specifications

ParametroSpecifica
SPD ClassificationType 1 + Type 2 + Type 3 (T1+T2+T3) · IEC 61643-11
Max Continuous Operating Voltage (Uc)275 V AC (L-N) · 255 V AC (N-PE)
Lightning Impulse Current (Iimp, 10/350 μs)6.25 kA / 8 kA / 12.5 kA (L-N) · 25 kA (N-PE)
Nominal Discharge Current (In, 8/20 μs)6.25 kA / 8 kA / 12.5 kA (L-N) · 25 kA (N-PE)
Open-Circuit Voltage (Uoc, T3)20 kV
Livello di protezione della tensione (Up)1.25 kV (L-N) · 1.5 kV (N-PE)
Follow Current Interrupt Rating (Ifi)300 A (L-N) · 100 A (N-PE) · TOV N-PE: 1200 V
Residual Leakage Current (Ipe)NONE · Isccr: 25,000 A
Recommended Backup SCBVIOX VSP-SSD50X
Terminals & Housing6–25 mm² (2.5 N·m) · Black PBT/PA UL94 V-0 · IP20 · -40°C to +70°C

VSP-T15/B+C Available Poles & Dimensions

Poli1P1+NPE / 2P3P4P / 3+NPE
Dimensions (W × H × D)18 × 90 × 67 mm36 × 90 × 67 mm54 × 90 × 67 mm72 × 90 × 67 mm

Dimensioni e installazione

VIOX VSP-T15/B+C AC Type 1+2+3 Combined Surge Protection Device (Iimp 12.5kA) Dimensional Drawing (mm)
VSP-T15/B+C Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Install at the main service entrance (LPZ 0A/0B → LPZ 1) for buildings with external lightning protection systems (LPS Class III/IV) or overhead service drops.
  • Pair with VIOX VSP-SSD50X (Type 1 SCB) for coordinated lightning impulse withstand without nuisance tripping.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

FAQ

Why choose a T1+T2+T3 combined SPD like VSP-T15/B+C?

A single VSP-T15/B+C device replaces separate Type 1 and Type 2 arresters in compact distribution boards while keeping residual clamping voltage down to 1.25 kV.

Hai bisogno di un preventivo?
Costruiamolo insieme.

Inviaci il modello del prodotto, le caratteristiche tecniche, la quantità e i requisiti OEM. Il nostro team esaminerà la tua richiesta e risponderà entro un giorno lavorativo.

Richiesta di preventivo