VIOX ELECTRIC
اللغة

VIOX VSP-T15/B+C AC Type 1+2+3 Combined Surge Protection Device (Iimp 12.5kA)

The VIOX VSP-T15/B+C is an all-in-one Type 1 + Type 2 + Type 3 (T1+T2+T3) AC lightning current and surge arrester housed in a high-strength black industrial enclosure. Delivering Iimp 6.25 kA, 8 kA, or 12.5 kA (10/350 μs) per pole and Uoc 20 kV (Type 3) with ultra-low Up 1.25 kV clamping, it protects main incoming panels against both direct lightning strikes and switching transients in a compact 18 mm-per-pole footprint.

سلسلة VIOX
VSP-T15/B+C
الجهد المقنن
AC 275V (L-N) / 255V (N-PE)
Surge Rating
Iimp 6.25 / 8 / 12.5 kA (10/350μs)
قياسي
IEC 61643-11 · T1+T2+T3 · CE / CB

نظرة عامة

The VIOX VSP-T15/B+C is an all-in-one Type 1 + Type 2 + Type 3 (T1+T2+T3) AC lightning current and surge arrester housed in a high-strength black industrial enclosure. Delivering Iimp 6.25 kA, 8 kA, or 12.5 kA (10/350 μs) per pole and Uoc 20 kV (Type 3) with ultra-low Up 1.25 kV clamping, it protects main incoming panels against both direct lightning strikes and switching transients in a compact 18 mm-per-pole footprint.

الميزات

  • True T1+T2+T3 combined arrester: handles 10/350 μs lightning current (Iimp 6.25 / 8 / 12.5 kA L-N; 25 kA N-PE) and 20 kV Type 3 combination wave.
  • Ultra-low voltage protection level Up 1.25 kV (L-N) and 1.5 kV (N-PE) protects sensitive downstream electronics without requiring a separate T2 stage.
  • Zero follow-current / leakage-free N-PE GDT path (Ipe = NONE) with 25,000 A short-circuit rating (Isccr).
  • Compact 18 mm/pole modular width (1P, 1+NPE, 2P, 3P, 4P, 3+NPE) with built-in thermal disconnector and remote signaling contacts.

المواصفات

VSP-T15/B+C Electrical & Mechanical Specifications

المعلمةالمواصفات
SPD ClassificationType 1 + Type 2 + Type 3 (T1+T2+T3) · IEC 61643-11
Max Continuous Operating Voltage (Uc)275 V AC (L-N) · 255 V AC (N-PE)
Lightning Impulse Current (Iimp, 10/350 μs)6.25 kA / 8 kA / 12.5 kA (L-N) · 25 kA (N-PE)
Nominal Discharge Current (In, 8/20 μs)6.25 kA / 8 kA / 12.5 kA (L-N) · 25 kA (N-PE)
Open-Circuit Voltage (Uoc, T3)20 كيلوفولت
مستوى حماية الجهد (Up)1.25 kV (L-N) · 1.5 kV (N-PE)
Follow Current Interrupt Rating (Ifi)300 A (L-N) · 100 A (N-PE) · TOV N-PE: 1200 V
Residual Leakage Current (Ipe)NONE · Isccr: 25,000 A
Recommended Backup SCBVIOX VSP-SSD50X
Terminals & Housing6–25 mm² (2.5 N·m) · Black PBT/PA UL94 V-0 · IP20 · -40°C to +70°C

VSP-T15/B+C Available Poles & Dimensions

القطبين1P1+NPE / 2P3P4P / 3+NPE
Dimensions (W × H × D)18 × 90 × 67 mm36 × 90 × 67 mm54 × 90 × 67 mm72 × 90 × 67 mm

الأبعاد والتركيب

VIOX VSP-T15/B+C AC Type 1+2+3 Combined Surge Protection Device (Iimp 12.5kA) Dimensional Drawing (mm)
VSP-T15/B+C Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Install at the main service entrance (LPZ 0A/0B → LPZ 1) for buildings with external lightning protection systems (LPS Class III/IV) or overhead service drops.
  • Pair with VIOX VSP-SSD50X (Type 1 SCB) for coordinated lightning impulse withstand without nuisance tripping.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

الأسئلة الشائعة

Why choose a T1+T2+T3 combined SPD like VSP-T15/B+C?

A single VSP-T15/B+C device replaces separate Type 1 and Type 2 arresters in compact distribution boards while keeping residual clamping voltage down to 1.25 kV.

هل تحتاج إلى عرض سعر للمنتج؟
لنبنيها معاً.

أرسل لنا طراز المنتج، والتقييمات الفنية، والكمية، ومتطلبات الشركة المصنعة للمعدات الأصلية (OEM). سيقوم فريقنا بمراجعة طلبك والرد في غضون يوم عمل واحد.

طلب عرض أسعار