VIOX ELECTRIC
زبان

VIOX VSP-T15/B+C AC Type 1+2+3 Combined Surge Protection Device (Iimp 12.5kA)

The VIOX VSP-T15/B+C is an all-in-one Type 1 + Type 2 + Type 3 (T1+T2+T3) AC lightning current and surge arrester housed in a high-strength black industrial enclosure. Delivering Iimp 6.25 kA, 8 kA, or 12.5 kA (10/350 μs) per pole and Uoc 20 kV (Type 3) with ultra-low Up 1.25 kV clamping, it protects main incoming panels against both direct lightning strikes and switching transients in a compact 18 mm-per-pole footprint.

سری VIOX
VSP-T15/B+C
ولتاژ نامی
AC 275V (L-N) / 255V (N-PE)
Surge Rating
Iimp 6.25 / 8 / 12.5 kA (10/350μs)
استاندارد
IEC 61643-11 · T1+T2+T3 · CE / CB

نمای کلی

The VIOX VSP-T15/B+C is an all-in-one Type 1 + Type 2 + Type 3 (T1+T2+T3) AC lightning current and surge arrester housed in a high-strength black industrial enclosure. Delivering Iimp 6.25 kA, 8 kA, or 12.5 kA (10/350 μs) per pole and Uoc 20 kV (Type 3) with ultra-low Up 1.25 kV clamping, it protects main incoming panels against both direct lightning strikes and switching transients in a compact 18 mm-per-pole footprint.

ویژگی‌ها

  • True T1+T2+T3 combined arrester: handles 10/350 μs lightning current (Iimp 6.25 / 8 / 12.5 kA L-N; 25 kA N-PE) and 20 kV Type 3 combination wave.
  • Ultra-low voltage protection level Up 1.25 kV (L-N) and 1.5 kV (N-PE) protects sensitive downstream electronics without requiring a separate T2 stage.
  • Zero follow-current / leakage-free N-PE GDT path (Ipe = NONE) with 25,000 A short-circuit rating (Isccr).
  • Compact 18 mm/pole modular width (1P, 1+NPE, 2P, 3P, 4P, 3+NPE) with built-in thermal disconnector and remote signaling contacts.

مشخصات

VSP-T15/B+C Electrical & Mechanical Specifications

پارامترمشخصات
SPD ClassificationType 1 + Type 2 + Type 3 (T1+T2+T3) · IEC 61643-11
Max Continuous Operating Voltage (Uc)275 V AC (L-N) · 255 V AC (N-PE)
Lightning Impulse Current (Iimp, 10/350 μs)6.25 kA / 8 kA / 12.5 kA (L-N) · 25 kA (N-PE)
Nominal Discharge Current (In, 8/20 μs)6.25 kA / 8 kA / 12.5 kA (L-N) · 25 kA (N-PE)
Open-Circuit Voltage (Uoc, T3)20 kV
سطح حفاظت ولتاژ (Up)1.25 kV (L-N) · 1.5 kV (N-PE)
Follow Current Interrupt Rating (Ifi)300 A (L-N) · 100 A (N-PE) · TOV N-PE: 1200 V
Residual Leakage Current (Ipe)NONE · Isccr: 25,000 A
Recommended Backup SCBVIOX VSP-SSD50X
Terminals & Housing6–25 mm² (2.5 N·m) · Black PBT/PA UL94 V-0 · IP20 · -40°C to +70°C

VSP-T15/B+C Available Poles & Dimensions

لهستانی‌ها1P1+NPE / 2P3P4P / 3+NPE
Dimensions (W × H × D)18 × 90 × 67 mm36 × 90 × 67 mm54 × 90 × 67 mm72 × 90 × 67 mm

ابعاد و نصب

VIOX VSP-T15/B+C AC Type 1+2+3 Combined Surge Protection Device (Iimp 12.5kA) Dimensional Drawing (mm)
VSP-T15/B+C Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Install at the main service entrance (LPZ 0A/0B → LPZ 1) for buildings with external lightning protection systems (LPS Class III/IV) or overhead service drops.
  • Pair with VIOX VSP-SSD50X (Type 1 SCB) for coordinated lightning impulse withstand without nuisance tripping.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

سوالات متداول

Why choose a T1+T2+T3 combined SPD like VSP-T15/B+C?

A single VSP-T15/B+C device replaces separate Type 1 and Type 2 arresters in compact distribution boards while keeping residual clamping voltage down to 1.25 kV.

نیاز به استعلام قیمت محصول دارید؟
بیایید با هم بسازیم.

مدل محصول، مشخصات فنی، تعداد و الزامات OEM خود را برای ما ارسال کنید. تیم ما درخواست شما را بررسی کرده و ظرف یک روز کاری پاسخ خواهد داد.

درخواست قیمت