15mm Capacitive Proximity Sensor KI5001
VIOX’s KI5001 capacitive proximity sensors provide non-contact detection of any material based on changes in electrical capacitance. With a 10-36VDC power supply, PNP normally closed (NC) output, and up to 15mm sensing range in a robust M30 metal cylindrical housing, the KI5001 ensures reliable detection for diverse industrial applications.
Send your requirements, we will quote for you within 12 hours
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:[email protected]
| Model | KI5001 | KI0016 | |
| Product characteristics |
Electrical design | PNP | |
| Output function | normally closed | normally open | |
| Sensing range(mm) | 15 | 15 | |
| Housing | Threaded type | Threaded type | |
| Dimensions(mm) | M30 x 1.5 / L = 81 | M30 x 1.5 / L = 81 | |
| Application | Medium temperature(℃) | ||
| Electrical date |
Operating voltage(V) | 10-36 DC | 20-250 AC/DC |
| Current consumption(mA) | 13; (24 V) | ||
| Protection class | II | II | |
| Reverse polarity protection | no | ||
| Output | Electrical design | PNP | |
| Output function | normally closed | normally open | |
| Max.voltage drop switching output DC(V) |
2.5 | 8 | |
| Max.voltage drop switching output AC(V) |
10 | ||
| Minimum load current(mA) | 5 | ||
| Max.leakage current(mA) | 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) | ||
| Permanent current rating of switching output AC(mA) |
200; (for UL application: 250 / 100 DC) | ||
| Permanent current rating of switching output DC(mA) |
250 | 200; (for UL application: 250 AC / 100 DC) | |
| Short-time current rating of switching output(mA) |
1500; (20 ms / 0,5 Hz) | ||
| Switching frequency AC(Hz) | 25 | ||
| Switching frequency DC(Hz) | 40 | 40 | |
| Short-circuit proof | yes | no | |
| Overload protection | yes | no | |
| Monitoring range |
Sensing range(mm) | 15 | 15 |
| Sensing range adjustable | yes | yes | |
| Factory setting sening range(mm) | 15 | 15 | |
| Real sening range Sr(mm) | 15 ± 10 % | 15 ± 10 % | |
| Opeating distance(mm) | 0-12.1 | 0-12.1 | |
| Accuracy/deviations | Correction factor | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
| Hysteresis (% of Sr) | 1~15 | 1~15 | |
| Switch-point drift(% of Sr) | -15-15 | -15-15 | |
| Operating conditions |
Ambient temperature(℃) | -27-70 | -25-70 |
| Protection | IP 65 | IP 65 | |
| Increased immunity | yes; (Increased immunity to conducted radio frequency interference) |
yes; (Increased immunity to conducted radio frequency interference) |
|
| Test/approvals | EMC | EN 60947-5-2 | EN 60947-5-2 |
| MTTF(years) | 778 | 489 | |
| Mechanical data | Weight(g) | 195 | 196 |
| Housing | Threaded type | Threaded type | |
| Mountable | non-flush mountable | non-flush mountable | |
| Dimensions(mm) | M30 x 1.5 / L = 81 | M30 x 1.5 / L = 81 | |
| Thread designation | M30 x 1.5 | M30 x 1.5 | |
| Material | PBT | PBT | |
| Display | Display | Switching status 1 x LED, yellow | Switching status 1 x LED, yellow |
| Electrical connection | Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
|
| Accessories | lock nuts: 2 | lock nuts: 2 | |
| Remarks | Remarks | Recommendation: check the unit for reliable function after a short circuit. | |
| Pack quantity | 1 pcs | 1 pcs | |
| Electrical connection | Connection | Cable: 2 m, PVC; 3 x 0.5 mm² | Cable: 2 m, PVC; 2 x 0.5 mm² |