VIOX ELECTRIC
Langue

VIOX VM7E-ZB Series Multifunctional Phase-Change Switch with HPLC Carrier (125A–250A)

VIOX VM7E-ZB Series Multifunctional Phase-Change Switch (125 A, 160 A, 250 A; AC 400 V / 220 V; 8–10 ms transfer; ≥50,000 cycles) upgrades the VM7E permanent-magnet platform with an integrated HPLC power-line carrier module, power metering, and full remote control for smart-grid phase balancing.

Frame Range
125 / 160 / 250 A (50–250 A)
Carrier Module
Integrated HPLC Power-Line Carrier
Transfer & Life
8–10 ms · ≥50,000 Cycles
Protection de l'environnement
20 kA Icu · Leakage · Auto-Reclose

Vue d'ensemble

The VIOX VM7E-ZB Series (VM7E-125ZB, VM7E-160ZB, VM7E-250ZB) is a multifunctional three-phase unbalanced commutation switch equipped with a built-in single-phase HPLC power-line carrier module. Communicating directly over existing power lines with a central transformer-area terminal, VM7E-ZB coordinates 8–10 ms permanent-magnet phase switching, real-time power metering, early-warning protection, and remote control inside a compact 190 × 140 × 124 mm enclosure.

Caractéristiques

  • Integrated HPLC carrier communication module eliminates separate control-cable trenching.
  • Ultra-fast 8–10 ms electronic permanent-magnet phase commutation (≥50,000 cycles).
  • Three ratings in one 190 × 140 × 124 mm body: VM7E-125ZB, VM7E-160ZB, and VM7E-250ZB.
  • Built-in power metering, remote control, early-warning protection, and 20–60 s auto-reclosing.
  • AC 400 V / 220 V, Ui 1000 V, Uimp 8 kV, 20 kA Icu / 10 kA Ics, Icw 3 kA/0.3s.
  • Front LED phase indicators (A / B / C) and quick manual/auto test buttons.

Modèles

ModèleRated Current In (A)Carrier & MeteringTemps de transfertDimensions b×a×ca (mm)
VM7E-125ZB125 A (50–125 A)HPLC Carrier + Metering + Remote8–10 ms190 × 140 × 124
VM7E-160ZB160 A (63–160 A)HPLC Carrier + Metering + Remote8–10 ms190 × 140 × 124
VM7E-250ZB250 A (100–250 A)HPLC Carrier + Metering + Remote8–10 ms190 × 140 × 124

Spécifications

Electrical & Protection Specifications

ParamètreSpécification
Rated voltage / Ui / UimpAC 400 V / 220 V · Ui 1000 V · Uimp 8 kV
Breaking capacity (Icu / Ics)20 kA / 10 kA · Icw 3 kA/0.3s
Phase-change action time8–10 ms (electronic permanent-magnet)
Operation cycles≥ 50,000 cycles
Leakage & auto-reclosingAC type · 20–60 s
Caractéristique de surintensité1.05×In non-trip (2 h) · 1.30×In trip (2 h)
Smart modulesPower metering, HPLC carrier, remote control

Guide de sélection

Position du codeSignificationCatalog Value or Options
VM7ESérieThree-phase unbalanced commutation switch
125 / 160 / 250Courant nominal125 A, 160 A, or 250 A
ZBModule suffixIntegrated HPLC carrier + power metering + remote control

1. Eliminate Signal Cabling

Use HPLC power-line carrier communication to coordinate multiple pole-mounted phase switches.

2. Track Feeder Energy

Built-in metering logs phase-by-phase consumption and imbalance history.

3. Fast 8–10 ms Transfer

Permanent-magnet drive ensures quiet, rapid load shifting with ≥50,000-cycle durability.

4. Check 124 mm Depth

Confirm 124 mm cabinet depth for the plug-in carrier module.

Installation

  • Seat the plug-in HPLC carrier module firmly before applying AC 400 V / 220 V power.
  • Confirm A/B/C/N incoming phase order and verify front LED phase indicators during startup.
  • Compare with standard VM7E when carrier communication is not required.

FAQ

What does the ZB suffix add on VM7E-ZB?

ZB adds an integrated HPLC power-line carrier module alongside power metering and remote control, enabling coordinated phase balancing over existing AC power lines.

What is the transfer speed of VM7E-ZB?

8–10 ms via an electronic permanent-magnet actuator.

What are the dimensions of VM7E-ZB?

190 × 140 × 124 mm across all three ratings (125 A, 160 A, and 250 A).

Does VM7E-ZB include earth-leakage and auto-reclosing?

Yes. It includes AC-type residual-current protection and 20–60 s automatic reclosing.

How many switching operations is VM7E-ZB rated for?

≥50,000 cycles (up to 100,000 mechanical endurance).

What is the breaking capacity of VM7E-ZB?

20 kA Icu / 10 kA Ics with 3 kA/0.3s short-time withstand current.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Besoin d'un devis produit ?
Construisons-le ensemble.

Envoyez-nous le modèle du produit, les caractéristiques techniques, la quantité et les exigences OEM. Notre équipe examinera votre demande et vous répondra dans un délai d'un jour ouvré.

Demander un Devis