VIOX ECB Series Cost-Control & Utility Molded Case Circuit Breaker (160A–1600A)

VIOX ECB Series 3-Pole Cost-Control Molded Case Circuit Breaker (160 A–1600 A, AC 230/400 V, Ui 1000 V, Uimp 8 kV, Class B, up to 100 kA Icu / 85 kA Ics) is built for Middle East and utility metering enclosures with integrated cost-control switching, heavy-duty terminal posts, padlocking, and protective covers.

Frame Range
160–1600 A (6 Frames · 3P)
Max Breaking (400V)
Up to 100 kA Icu / 85 kA Ics
Utility Hardware
Terminal Posts · Padlock · Cover
Category & Ui
Class B · Ui 1000 V / Uimp 8 kV

Обзор

The VIOX ECB Series is a heavy-duty 3-pole cost-control molded case circuit breaker tailored for utility metering enclosures, commercial prepaid distribution, and Middle East grid specifications. Covering 6 frames from 160 A to 1600 A (16 A–1600 A, AC 230/400 V, Ui 1000 V, Uimp 8 kV, Class B), ECB integrates cost-control disconnect functionality, extended terminal posts, tamper-evident padlocking, and protective terminal covers—with breaking capacity reaching 100 kA Icu / 85 kA Ics on ECB-1600.

Характеристики

  • Engineered for utility metering and Middle East distribution board requirements.
  • 6 three-pole frames: ECB-160, 250, 400/630, 800, 1250, and 1600 A (16 A–1600 A).
  • High breaking capacity: 100% Ics = Icu (20–40 kA) from 160 A to 1250 A, and 100 kA Icu / 85 kA Ics on ECB-1600 at AC 400 V.
  • Integrated cost-control switching, extended terminal posts, padlocking provision, and protective terminal covers.
  • Utilization Category Class B with Ui = 1000 V and Uimp = 8 kV per IEC/EN 60947-2.
  • Up to 10,000 mechanical cycles (with maintenance) on 160–250 A frames.

Модели

МодельRated Current In (A)ПолюсаIcu / Ics (400 V)Dimensions W×L×H (mm)
ECB-16016–160 A3P20 кА / 20 кА155 × 90 × 117
ECB-250100–250 A3P20 кА / 20 кА208 × 105 × 115
ECB-400/630250–400 A · 400–630 A3P20 кА / 20 кА337 × 168 × 155
ECB-800500–800 A3P40 kA / 40 kA418 × 238 × 168
ECB-12501000–1250 A3P40 kA / 40 kA418 × 238 × 168
ECB-16001250–1600 A3P100 kA / 85 kA210 × 340 × 229

Технические характеристики

Electrical & Endurance Data (3P, AC 230/400 V)

МодельIcu / Ics (230 V)Icu / Ics (400 V)Электрическая жизньMech. Life (Maint-Free / w/ Maint)
ECB-16025 / 25 kA20 / 20 kA1,0007,000 / 10,000
ECB-25025 / 25 kA20 / 20 kA1,0007,000 / 10,000
ECB-400/63025 / 25 kA20 / 20 kA1,0004,000 / 7,000
ECB-80065 / 65 kA40 / 40 kA5002,500 / 5,000
ECB-125065 / 65 kA40 / 40 kA5002,500 / 3,500
ECB-160075 / 65 kA100 / 85 kA5002,500 / 3,500

Руководство по выбору

Код позицииЗначениеCatalog Value or Options
ECBСерия3P Cost-control & utility molded case circuit breaker
160–1600Номинальный ток корпуса160, 250, 400/630, 800, 1250, 1600 A
3PПолюсаThree-pole utility configuration with terminal posts & protective cover

1. Meet Utility Specs

Specify ECB for Middle East and regional utility enclosures requiring terminal posts and padlockable covers.

2. Verify 100% Ics = Icu

160–1250 A frames offer Ics = 100% Icu; ECB-1600 scales to 100 kA Icu / 85 kA Ics.

3. Integrate Cost Control

Connect smart-meter disconnect signals for remote utility billing enforcement.

4. Check Enclosure Cutout

Review exact W × L × H dimensions including protective terminal covers.

Установка

  • Secure the included protective terminal covers and utility seal/padlock after cable termination.
  • Verify torque on extended terminal posts before energizing high-current 800–1600 A feeders.
  • Explore the complete VIOX MCCB portfolio for standard IEC 60947-2 panels.

ЧАСТО ЗАДАВАЕМЫЕ ВОПРОСЫ

What makes ECB different from standard VM6 MCCBs?

ECB is purpose-built for utility and Middle East metering enclosures, adding integrated cost-control disconnect functionality, extended terminal posts, padlocking provisions, and protective terminal covers.

What current range does ECB cover?

Six 3-pole frames from 160 A to 1600 A covering rated currents from 16 A through 1600 A.

What is the breaking capacity of ECB at 400 V AC?

20 kA Icu/Ics on 160–630 A, 40 kA Icu/Ics on 800–1250 A, and 100 kA Icu / 85 kA Ics on ECB-1600.

Are protective terminal covers and locks included?

Yes. ECB is designed with terminal posts, lock provision, and protective covers for tamper-resistant utility installations.

What utilization category is ECB?

Utilization Category Class B with Ui = 1000 V and Uimp = 8 kV.

Can VIOX supply ECB with custom utility markings?

Yes. VIOX supports OEM/utility specification markings and export documentation.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Нужен расчет стоимости продукции?
Давайте создавать вместе.

Отправьте нам модель изделия, технические характеристики, количество и требования OEM. Наша команда рассмотрит вашу заявку и ответит в течение одного рабочего дня.

Запрос Цитировать