VIOX ELECTRIC
Jazyk

VIOX VM7 Series New Energy High-Voltage AC MCCB (800V / 1000V / 1140V, 320A–630A)

VIOX VM7 Series New Energy High-Voltage AC MCCB (VM7-320 and VM7-630, 3P, 16 A–630 A) is engineered for AC 380/415 V, 690 V, 800 V, 1000 V, and 1140 V networks (Ui 1200 V, Uimp 12 kV, Ics = 100% Icu up to 50 kA at 800 V and 20 kA at 1140 V) in solar PV inverter AC combiners, wind power, mining, and metallurgy.

Rated Voltage Ue
AC 800 V / 1000 V / 1140 V
Frame & Current
VM7-320 / VM7-630 (16–630 A)
Breaking (Ics=Icu)
50 kA @800V · 30 kA @1000V · 20 kA @1140V
Insulation & Life
Ui 1200 V · Uimp 12 kV · 15,000 Mech

Přehled

Modern utility-scale solar string inverters (800 V AC output), wind power converters, and mining/metallurgy power networks require molded case circuit breakers rated well above standard 400 V/690 V switchgear. The VIOX VM7 Series (VM7-320 and VM7-630, 3P, 16 A–630 A) is engineered specifically for AC 800 V, AC 1000 V, and AC 1140 V service with Ui = 1200 V, Uimp = 12 kV, 3500 V dielectric withstand, 100% Ics = Icu breaking performance, and modular snap-in internal accessories for rapid field replacement.

Funkce

  • Wide high-voltage AC ratings: 380/415 V, 690 V, 800 V, 1000 V, and 1140 V AC (50/60 Hz).
  • 100% service breaking capacity (Ics = Icu): 100 kA @400V, 65 kA @690V, 50 kA @800V, 30 kA @1000V, and 20 kA @1140V (H tier).
  • Reinforced insulation: Ui = 1200 V, Uimp = 12 kV, 1-minute power-frequency withstand = 3500 V.
  • Two compact 3P frames: VM7-320 (16–320 A, 120×200×103 mm) and VM7-630 (225–630 A, 158×325×177 mm).
  • High endurance: 15,000 mechanical operations, 50 mm arc distance, instantaneous release 10×In or 15×In.
  • Modular internal accessories (codes 00–78) for fast, tool-light field replacement.

Modely

ModelRated Current In (A)PoláciRated Voltage Ue (AC)Dimensions W×L×H (mm)
VM7-32016, 20, 25, 32, 40, 50, 63, 75, 80, 100, 125, 140, 160, 180, 200, 225, 250, 320 A3P380/415 · 690 · 800 · 1000 · 1140 V120 × 200 × 103
VM7-630225, 250, 320, 350, 400, 500, 630 A3P380/415 · 690 · 800 · 1000 · 1140 V158 × 325 × 177

Specifikace

High-Voltage Breaking Capacity (Icu = Ics)

Breaking TierAC 380/415 VAC 690 VAC 800 VAC 1000 VAC 1140 V
H Tier (Icu = Ics)100 kA65 kA50 kA30 kA20 kA
M Tier (Icu = Ics)—60 kA50 kA20 kA12 kA
Electrical Life (Cycles)15,0003,0001,0001,0001,000

Insulation & Mechanical Specifications

ParametrSpecifikace
Jmenovité izolační napětí (Ui)1200 V
Jmenovité impulzní výdržné napětí (Uimp)12 kV
Power-frequency withstand voltage (1 min)3500 V
Mechanická životnost15,000 cycles
Arcing distance50 mm
Instantaneous release10×In or 15×In
Reference ambient temperature40 °C

Průvodce výběrem

Pozice kóduVýznamCatalog Value or Options
VM7SériovéNew energy high-voltage AC MCCB (up to AC 1140 V)
320 / 630Jmenovitý proud rámuVM7-320 (16–320 A) or VM7-630 (225–630 A)
M / HBreaking tierM (up to 50 kA @800V) or H (50 kA @800V / 30 kA @1000V / 20 kA @1140V)
3PPoláci3-Pole high-voltage AC configuration
00–78Internal accessory code00 None · 08 Alarm · 10 Shunt · 18 Shunt+Alarm · 20/27 Aux · 28/29 Aux+Alarm · 30 UVT · 38 UVT+Alarm · 40/41/48 Shunt+Aux · 50 Shunt+UVT · 60–69 Multi-Aux · 70–78 UVT+Aux (DC 24/110/220 V, AC 230/400 V)

1. Match Inverter AC Bus

Use VM7 on 800 V AC utility solar inverter AC combiner boxes where 690 V MCCBs are under-rated.

2. Verify 100% Ics = Icu

Both M and H tiers deliver Ics = 100% Icu across 690–1140 V AC for reliable post-fault re-energization.

3. Check Arc Clearance

Maintain the specified 50 mm arc distance above the breaker inside compact outdoor skid enclosures.

4. Pair with DC Protection

Combine VM7 on the AC side with VM7DC 1500 V DC on the PV array side.

Instalace

  • Verify 50 mm arc-zone clearance and phase barriers when installing in 800–1140 V AC cabinets.
  • Confirm ambient derating if outdoor solar combiner cabinets exceed the 40 °C reference temperature.
  • Modular internal accessories (shunt, UVT, aux, alarm) snap into dedicated left/right pockets.
  • Prozkoumejte VIOX Solární energie a skladování energie a Slučovač Box solutions.

ČASTO KLADENÉ DOTAZY

Why do 1500 V DC solar plants need an 800 V AC MCCB like VM7?

Utility-scale 1500 V DC string inverters output 800 V AC to step-up transformers. Standard 400 V/690 V MCCBs lack the insulation (Ui 1200 V) and high-voltage arc-quenching capacity required at 800 V AC.

What is the breaking capacity of VM7 at 800 V, 1000 V, and 1140 V AC?

In the H tier, VM7 achieves Icu = Ics = 50 kA at 800 V AC, 30 kA at 1000 V AC, and 20 kA at 1140 V AC.

Where else is VM7 used besides solar PV?

VM7 is widely specified in wind turbine nacelles/towers, underground coal and metal mining (1140 V AC), and metallurgical heavy industrial drives.

What are the physical dimensions of VM7-320 and VM7-630?

VM7-320 measures 120 × 200 × 103 mm; VM7-630 measures 158 × 325 × 177 mm (W × L × H).

What instantaneous trip options are available?

VM7 offers 10×In or 15×In instantaneous magnetic release settings to coordinate with inverter or motor inrush.

Does VM7 support shunt trip and auxiliary contacts?

Yes. VM7 features modular internal accessory pockets supporting codes 00–78 (alarm, shunt, UVT, auxiliary contacts) for rapid field replacement.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Potřebujete cenovou nabídku produktu?
Pojďme to vybudovat společně.

Zašlete nám model produktu, technické parametry, množství a požadavky OEM. Náš tým vaši žádost posoudí a odpoví do jednoho pracovního dne.

Požádat o cenovou Nabídku