Compare six dedicated VIOX industrial AC contactor platforms—from 6 A miniature DIN-rail units to 800 A heavy-duty motor contactors, wide-voltage AC/DC electronic coils, and 4-pole resistive switching.

6–800 A AC-34–450 kW at 380/400 V AC
AC & Electronic CoilsFixed AC 24–400 V · Wide AC/DC 24–240 V
2P / 3P / 4PIEC/EN 60947-4-1 · OEM Direct
VIOX AC contactor series collection on a white studio background

VIOX AC Contactor Series (6 Models)

Six dedicated industrial AC contactor platforms covering 6 A through 800 A AC-3 duty—select a model to inspect full specifications.

VIOX CJX2s Standard AC Contactor
Standardní průmyslové

CJX2s

VIOX CJX2s Standard AC Contactor

AC-3 Rating
9–110 A
Power / Duty
4–55 kW (380/400 V)
Poláci
3P
Control Coil
AC 50/60 Hz (24–400 V)
VIOX CJX2s AC stykač pro vysoké proudy
Heavy Duty

CJX2s vysokoproudé

VIOX CJX2s AC stykač pro vysoké proudy

AC-3 Rating
120–800 A
Power / Duty
55–450 kW (380/400 V)
Poláci
3P
Control Coil
AC / DC control coil
Stykač VIOX CJX2s-W s elektronickou cívkou AC
Electronic Coil

CJX2s-W

Stykač VIOX CJX2s-W s elektronickou cívkou AC

AC-3 Rating
9–95 A
Power / Duty
4–45 kW (380/400 V)
Poláci
3P
Control Coil
AC/DC 24 V, 48 V, 100–240 V
Čtyřpólový AC stykač VIOX CJX2s-4P
4-Pole AC-1 / AC-3

CJX2s-4P

Čtyřpólový AC stykač VIOX CJX2s-4P

AC-3 Rating
9–95 A (Ui 690 V)
Power / Duty
Resistive / 4P switching
Poláci
4P (04: 4NO · 08: 2NO+2NC)
Control Coil
AC 50/60 Hz
Miniaturní stykač AC VIOX CJX2s-M
Miniaturní

CJX2s-M

Miniaturní stykač AC VIOX CJX2s-M

AC-3 Rating
6–16 A
Power / Duty
2.2–7.5 kW (380/400 V)
Poláci
3P / 4P
Control Coil
AC coil, DC coil & pin-type
Kompaktní AC stykač VIOX KCC6-M
Compact OEM

KCC6-M

Kompaktní AC stykač VIOX KCC6-M

AC-3 Rating
9–38 A
Power / Duty
4–18.5 kW (380/400 V)
Poláci
2P / 3P
Control Coil
AC 50/60 Hz

Compare all six VIOX AC contactor series

Side-by-side comparison of published IEC 60947-4-1 AC-3 current ratings, motor power, pole options, and coil architectures.

Faktor výběru CJX2s CJX2s vysokoproudé CJX2s-W CJX2s-4P CJX2s-M KCC6-M
AC-3 current (380/400 V) 9–110 A120–800 A9–95 A9–95 A (Ui 690 V)6–16 A9–38 A
Motor power / duty 4–55 kW (380/400 V)55–450 kW (380/400 V)4–45 kW (380/400 V)Resistive / 4P switching2.2–7.5 kW (380/400 V)4–18.5 kW (380/400 V)
Poláci 3P3P3P4P (04: 4NO · 08: 2NO+2NC)3P / 4P2P / 3P
Řídicí cívka AC 50/60 Hz (24–400 V)AC / DC control coilAC/DC 24 V, 48 V, 100–240 VAC 50/60 HzAC coil, DC coil & pin-typeAC 50/60 Hz
Mounting / housing 35 mm DIN-rail or screwPanel base screw mount35 mm DIN-rail or screw35 mm DIN-rail or screwCompact DIN-rail / PCB pinCompact DIN-rail · IP40
Pomocné kontakty 1NO / 1NC / 1NO+1NC2NO + 2NC built-in1NO / 1NC / 1NO+1NCAdd-on front/side blocks1NO or 1NC built-in1NO or 1NC
Datasheet & SKU View CJX2s →View CJX2s High-Current →View CJX2s-W →View CJX2s-4P →View CJX2s-M →View KCC6-M →

Why Standard AC Contactors Fail in Real Panels — And How VIOX Engineers Around It

Field callbacks on motor control panels rarely stem from bench specs. They happen under locked-rotor inrush, sagging grid voltage, and uncoordinated fault energy.

01Contact Weld

Contact Welding & Single-Phasing

Undersized contacts weld under 6×In motor inrush or burn out one phase, causing destructive motor single-phasing.

VIOX EngineeringMatch verified IEC 60947-4-1 AC-3 ratings from 6 A to 800 A across CJX2s and KCC6-M.
02Coil Chatter

Coil Burnout on Unstable Grids

Voltage drops below 85% Us prevent AC armatures from sealing, spiking holding current until coil insulation burns.

VIOX EngineeringSpecifikujte CJX2s-W electronic coils (AC/DC 24 V, 48 V, 100–240 V) for silent, sag-immune hold.
03EMI Spike

PLC Resets at Coil Turn-Off

Inductive coil de-energization injects high-voltage back-EMF spikes onto control buses, resetting PLCs and pitting relay outputs.

VIOX EngineeringPair coils with RC/varistor suppressors per our suppressor sizing guide.
04Koordinace

Short-Circuit Let-Through Damage

Uncoordinated upstream breakers let excessive I²t fault energy weld or rupture contactor chambers during bolted faults.

VIOX EngineeringOvěřte Type 1 vs Type 2 coordination with matched upstream MPCB nebo MCCB.

IEC 60947-4-1 Utilization Category & Motor Power (kW) Sizing Guide

Unlike circuit breakers sized only by steady-state current, AC contactors must be matched to switching duty (AC-1, AC-3, AC-4), locked-rotor inrush, and coil stability at 380/400 V AC.

IEC 60947-4-1 AC-1, AC-3, and AC-4 utilization and motor kW sizing table for VIOX AC contactors
Duty / Motor Power Band (400 V) IEC Utilization Switching Stress Recommended VIOX Series Key Engineering Check
Small Motors (2.2–7.5 kW · 6–16 A) AC-3 Make 6×In · Break 1×In CJX2s-M Miniature Compact DIN-rail or PCB pin mount; AC/DC coil
OEM Machinery & HVAC (4–18.5 kW · 9–38 A) AC-3 Frequent compressor starts KCC6-M Compact 2P / 3P · IP40 housing for tight OEM panels
Standard Industrial Motors (4–55 kW · 9–110 A) AC-3 Make 6×In · Break 1×In CJX2s Standard Pair with nadproudové relé nebo MPCB
Heavy Industrial Drives (55–450 kW · 120–800 A) AC-3 High arc energy & busbar heat CJX2s vysokoproudé Built-in 2NO+2NC aux; verify Type 2 upstream MCCB
Unstable Grids & PLC Cabinets (4–45 kW · 9–95 A) AC-3 / AC-1 Voltage dips & cabinet heat CJX2s-W Electronic Coil AC/DC 24 V, 48 V, 100–240 V; zero coil chatter
Resistive Heating, Lighting & Neutral Switching AC-1 1×In continuous (cos φ ≥ 0.95) CJX2s-4P Four-Pole Select 04 (4NO) or 08 (2NO+2NC); Ui 690 V
Inching, Plugging & Frequent Reversing AC-4 Make 6×In · Break 6×In CJX2s (Derated 1–2 Frames) Add mechanical interlock + RC coil suppressor

How VIOX AC Contactors Compare Across IEC 60947-4-1 Tiers

Objective engineering benchmark across current span, wide-voltage electronic coil availability, pole architecture, and factory-direct B2B supply.

VIOX AC contactor benchmark against global Tier-1 and entry-tier lines
Evaluation Parameter Global Tier-1 Industrial Lines Entry-Tier Commodity Lines VIOX CJX2s / CJX2s-W / KCC6-M
Dodržování norem IEC/EN 60947-4-1 Basic AC-3 only IEC/EN 60947-4-1 (Full 6–800 A)
AC-3 Current & Power Span 6–800 A (up to 450 kW) Typically stops at 95 A 6–800 A (up to 450 kW at 400 V)
Wide-Voltage Electronic Coils Premium price tier Fixed AC coils only CJX2s-W: AC/DC 24 V, 48 V, 100–240 V
Specialty Configurations Mini, 3P, 4P, compact Standard 3P only Mini (M), 3P, 4P (04/08), Compact (KCC6-M)
OEM & Distributor Supply Fixed brand; long high-amp lead times Inconsistent silver-alloy & coil QA Factory-direct pricing + private-label OEM

Direct Factory Contactor Line

VIOX supplies all six IEC 60947-4-1 AC contactor platforms (6–800 A) directly from factory production—verified for coil pick-up and drop-out margins, silver-alloy contact endurance, dielectric strength, and private-label OEM laser marking across distributor and panel-builder programs.

AC Contactor Quotation Variables — What Moves Unit Pricing

Key technical and commercial drivers behind factory-direct AC contactor quotes. See also how to read a contactor model number.

Quotation variables for VIOX AC contactors
Quotation Variable Standard Spec Range Pricing & Lead-Time Impact
Frame Size & AC-3 Rating 6–16 A (Mini) · 9–110 A (Std) · 120–800 A (High-Current) Drives silver-alloy contact mass, arc chute size, and copper busbar weight
Coil Technology Standard AC 24–400 V vs CJX2s-W Electronic AC/DC 24–240 V Wide-voltage electronic coils reduce total SKU count across export markets
Pole & Auxiliary Count 2P / 3P / 4P (04 or 08) + built-in 1NO/1NC or 2NO+2NC Standard 3P 230 V coils carry fastest factory stock dispatch
Branding & Consolidation VIOX stock or OEM laser marking + custom inner boxes Consolidate with MCB, proudových chráničů (RCBO)a MCCB in one shipment

Sourcing Mixed-Amperage or OEM Private-Label AC Contactors?

Send your contactor current list, coil voltages, and pole counts—our factory team will return matched pricing, lead times, and evaluation samples.

Request AC Contactor Quote →

AC Contactor Selection & Procurement Questions

Direct answers on AC-1/AC-3/AC-4 sizing, CJX2s-W wide-voltage electronic coils, Type 1/Type 2 coordination, and OEM factory supply.

Využití What is the difference between AC-1, AC-3, and AC-4 ratings when sizing an AC contactor?

Under IEC 60947-4-1, AC-1 applies to non-inductive or slightly inductive resistive loads (heaters, lighting, distribution feeders) where switching current equals rated current. AC-3 governs standard squirrel-cage motor starting (6×In inrush) and switching off while running.

AC-4 covers severe inching, plugging, and frequent reversing where the contactor breaks full locked-rotor current (6×In). Always size motor contactors by AC-3 kW/A rating—and derate substantially for AC-4 duty to prevent contact welding.

Coil Selection When should I choose a CJX2s-W electronic-coil contactor instead of a standard laminated AC coil?

Specify VIOX CJX2s-W (9–95 A, AC/DC 24 V, 48 V, or 100–240 V wide-voltage electronic coils) on sites with unstable supply voltage, generator-backed panels, or high-density PLC cabinets where low coil holding power and hum-free operation matter.

Electronic coils eliminate coil chattering during voltage dips and allow one universal AC/DC coil SKU to replace multiple fixed-voltage inventory items across 50/60 Hz markets.

Series Comparison How do CJX2s, CJX2s High-Current, CJX2s-4P, CJX2s-M, and KCC6-M differ?

CJX2s (9–110 A, 4–55 kW) is the core 3P motor contactor; CJX2s High-Current scales to 120–800 A (55–450 kW) with built-in 2NO+2NC auxiliaries. CJX2s-4P (9–95 A, Ui 690 V) provides 4NO (04) or 2NO+2NC (08) main poles for resistive and neutral switching.

CJX2s-M (6–16 A, 3P/4P) serves tight DIN-rail or PCB/pin-type layouts, while KCC6-M (9–38 A, 2P/3P, IP40 housing) targets compact HVAC and OEM machinery panels.

Koordinace How do Type 1 and Type 2 short-circuit coordination work for AC contactors?

Under IEC 60947-4-1, Type 1 coordination permits contactor damage during a short circuit provided there is no external hazard, requiring replacement before restart. Type 2 coordination ensures the contactor remains operable after fault clearance with only minor, easily separable contact tacking.

Achieving Type 2 coordination depends on matching the VIOX AC contactor with a properly rated upstream MPCB, MCCB, or gG/aM fuse verified for the panel prospective short-circuit current.

Coil Protection Why should PLC-driven AC contactors include RC or varistor surge suppressors?

When an inductive AC contactor coil is de-energized, the collapsing magnetic field generates high-voltage switching transients that can reset nearby PLCs, trigger false sensor readings, or erode relay output contacts.

Mounting a dedicated RC or varistor surge suppressor across the coil terminals clamps these transients at the source and extends control-circuit service life.

OEM / B2B Supply Can VIOX supply OEM or private-label AC contactors with mixed coil voltages?

Yes. VIOX supports panel builders, OEM machinery manufacturers, and electrical wholesalers with factory-direct CJX2s and KCC6-M supply across mixed amperage and coil-voltage schedules, laser-marked private labeling, and IEC 60947-4-1 documentation.

Send your motor kW/A schedule, coil voltage, and pole configuration for matched factory pricing and lead times.

Potřebujete správný stykač AC?
Pojďme si to společně potvrdit.

Send your AC-3 motor kW/A rating, coil voltage, pole configuration, quantity, and target market. VIOX engineers will match the right CJX2s or KCC6-M series.

Request AC Contactor Quote