Stykače na střídavý proud (IEC 60947-4-1)
Compare six dedicated VIOX industrial AC contactor platforms—from 6 A miniature DIN-rail units to 800 A heavy-duty motor contactors, wide-voltage AC/DC electronic coils, and 4-pole resistive switching.
VIOX AC Contactor Series (6 Models)
Six dedicated industrial AC contactor platforms covering 6 A through 800 A AC-3 duty—select a model to inspect full specifications.
CJX2s
VIOX CJX2s Standard AC Contactor
- AC-3 Rating
- 9–110 A
- Power / Duty
- 4–55 kW (380/400 V)
- Poláci
- 3P
- Control Coil
- AC 50/60 Hz (24–400 V)
CJX2s vysokoproudé
VIOX CJX2s AC stykač pro vysoké proudy
- AC-3 Rating
- 120–800 A
- Power / Duty
- 55–450 kW (380/400 V)
- Poláci
- 3P
- Control Coil
- AC / DC control coil
CJX2s-W
Stykač VIOX CJX2s-W s elektronickou cívkou AC
- AC-3 Rating
- 9–95 A
- Power / Duty
- 4–45 kW (380/400 V)
- Poláci
- 3P
- Control Coil
- AC/DC 24 V, 48 V, 100–240 V
CJX2s-4P
Čtyřpólový AC stykač VIOX CJX2s-4P
- AC-3 Rating
- 9–95 A (Ui 690 V)
- Power / Duty
- Resistive / 4P switching
- Poláci
- 4P (04: 4NO · 08: 2NO+2NC)
- Control Coil
- AC 50/60 Hz
CJX2s-M
Miniaturní stykač AC VIOX CJX2s-M
- AC-3 Rating
- 6–16 A
- Power / Duty
- 2.2–7.5 kW (380/400 V)
- Poláci
- 3P / 4P
- Control Coil
- AC coil, DC coil & pin-type
KCC6-M
Kompaktní AC stykač VIOX KCC6-M
- AC-3 Rating
- 9–38 A
- Power / Duty
- 4–18.5 kW (380/400 V)
- Poláci
- 2P / 3P
- Control Coil
- AC 50/60 Hz
Compare all six VIOX AC contactor series
Side-by-side comparison of published IEC 60947-4-1 AC-3 current ratings, motor power, pole options, and coil architectures.
| Faktor výběru | CJX2s | CJX2s vysokoproudé | CJX2s-W | CJX2s-4P | CJX2s-M | KCC6-M |
|---|---|---|---|---|---|---|
| AC-3 current (380/400 V) | 9–110 A | 120–800 A | 9–95 A | 9–95 A (Ui 690 V) | 6–16 A | 9–38 A |
| Motor power / duty | 4–55 kW (380/400 V) | 55–450 kW (380/400 V) | 4–45 kW (380/400 V) | Resistive / 4P switching | 2.2–7.5 kW (380/400 V) | 4–18.5 kW (380/400 V) |
| Poláci | 3P | 3P | 3P | 4P (04: 4NO · 08: 2NO+2NC) | 3P / 4P | 2P / 3P |
| Řídicí cívka | AC 50/60 Hz (24–400 V) | AC / DC control coil | AC/DC 24 V, 48 V, 100–240 V | AC 50/60 Hz | AC coil, DC coil & pin-type | AC 50/60 Hz |
| Mounting / housing | 35 mm DIN-rail or screw | Panel base screw mount | 35 mm DIN-rail or screw | 35 mm DIN-rail or screw | Compact DIN-rail / PCB pin | Compact DIN-rail · IP40 |
| Pomocné kontakty | 1NO / 1NC / 1NO+1NC | 2NO + 2NC built-in | 1NO / 1NC / 1NO+1NC | Add-on front/side blocks | 1NO or 1NC built-in | 1NO or 1NC |
| Datasheet & SKU | View CJX2s → | View CJX2s High-Current → | View CJX2s-W → | View CJX2s-4P → | View CJX2s-M → | View KCC6-M → |
Why Standard AC Contactors Fail in Real Panels — And How VIOX Engineers Around It
Field callbacks on motor control panels rarely stem from bench specs. They happen under locked-rotor inrush, sagging grid voltage, and uncoordinated fault energy.
Contact Welding & Single-Phasing
Undersized contacts weld under 6×In motor inrush or burn out one phase, causing destructive motor single-phasing.
Coil Burnout on Unstable Grids
Voltage drops below 85% Us prevent AC armatures from sealing, spiking holding current until coil insulation burns.
PLC Resets at Coil Turn-Off
Inductive coil de-energization injects high-voltage back-EMF spikes onto control buses, resetting PLCs and pitting relay outputs.
Short-Circuit Let-Through Damage
Uncoordinated upstream breakers let excessive I²t fault energy weld or rupture contactor chambers during bolted faults.
IEC 60947-4-1 Utilization Category & Motor Power (kW) Sizing Guide
Unlike circuit breakers sized only by steady-state current, AC contactors must be matched to switching duty (AC-1, AC-3, AC-4), locked-rotor inrush, and coil stability at 380/400 V AC.
| Duty / Motor Power Band (400 V) | IEC Utilization | Switching Stress | Recommended VIOX Series | Key Engineering Check |
|---|---|---|---|---|
| Small Motors (2.2–7.5 kW · 6–16 A) | AC-3 | Make 6×In · Break 1×In | CJX2s-M Miniature | Compact DIN-rail or PCB pin mount; AC/DC coil |
| OEM Machinery & HVAC (4–18.5 kW · 9–38 A) | AC-3 | Frequent compressor starts | KCC6-M Compact | 2P / 3P · IP40 housing for tight OEM panels |
| Standard Industrial Motors (4–55 kW · 9–110 A) | AC-3 | Make 6×In · Break 1×In | CJX2s Standard | Pair with nadproudové relé nebo MPCB |
| Heavy Industrial Drives (55–450 kW · 120–800 A) | AC-3 | High arc energy & busbar heat | CJX2s vysokoproudé | Built-in 2NO+2NC aux; verify Type 2 upstream MCCB |
| Unstable Grids & PLC Cabinets (4–45 kW · 9–95 A) | AC-3 / AC-1 | Voltage dips & cabinet heat | CJX2s-W Electronic Coil | AC/DC 24 V, 48 V, 100–240 V; zero coil chatter |
| Resistive Heating, Lighting & Neutral Switching | AC-1 | 1×In continuous (cos φ ≥ 0.95) | CJX2s-4P Four-Pole | Select 04 (4NO) or 08 (2NO+2NC); Ui 690 V |
| Inching, Plugging & Frequent Reversing | AC-4 | Make 6×In · Break 6×In | CJX2s (Derated 1–2 Frames) | Add mechanical interlock + RC coil suppressor |
How VIOX AC Contactors Compare Across IEC 60947-4-1 Tiers
Objective engineering benchmark across current span, wide-voltage electronic coil availability, pole architecture, and factory-direct B2B supply.
| Evaluation Parameter | Global Tier-1 Industrial Lines | Entry-Tier Commodity Lines | VIOX CJX2s / CJX2s-W / KCC6-M |
|---|---|---|---|
| Dodržování norem | IEC/EN 60947-4-1 | Basic AC-3 only | IEC/EN 60947-4-1 (Full 6–800 A) |
| AC-3 Current & Power Span | 6–800 A (up to 450 kW) | Typically stops at 95 A | 6–800 A (up to 450 kW at 400 V) |
| Wide-Voltage Electronic Coils | Premium price tier | Fixed AC coils only | CJX2s-W: AC/DC 24 V, 48 V, 100–240 V |
| Specialty Configurations | Mini, 3P, 4P, compact | Standard 3P only | Mini (M), 3P, 4P (04/08), Compact (KCC6-M) |
| OEM & Distributor Supply | Fixed brand; long high-amp lead times | Inconsistent silver-alloy & coil QA | Factory-direct pricing + private-label OEM |
Direct Factory Contactor Line
VIOX supplies all six IEC 60947-4-1 AC contactor platforms (6–800 A) directly from factory production—verified for coil pick-up and drop-out margins, silver-alloy contact endurance, dielectric strength, and private-label OEM laser marking across distributor and panel-builder programs.
AC Contactor Quotation Variables — What Moves Unit Pricing
Key technical and commercial drivers behind factory-direct AC contactor quotes. See also how to read a contactor model number.
| Quotation Variable | Standard Spec Range | Pricing & Lead-Time Impact |
|---|---|---|
| Frame Size & AC-3 Rating | 6–16 A (Mini) · 9–110 A (Std) · 120–800 A (High-Current) | Drives silver-alloy contact mass, arc chute size, and copper busbar weight |
| Coil Technology | Standard AC 24–400 V vs CJX2s-W Electronic AC/DC 24–240 V | Wide-voltage electronic coils reduce total SKU count across export markets |
| Pole & Auxiliary Count | 2P / 3P / 4P (04 or 08) + built-in 1NO/1NC or 2NO+2NC | Standard 3P 230 V coils carry fastest factory stock dispatch |
| Branding & Consolidation | VIOX stock or OEM laser marking + custom inner boxes | Consolidate with MCB, proudových chráničů (RCBO)a MCCB in one shipment |
Sourcing Mixed-Amperage or OEM Private-Label AC Contactors?
Send your contactor current list, coil voltages, and pole counts—our factory team will return matched pricing, lead times, and evaluation samples.
AC contactor knowledge center
Engineering guides written for panel builders, maintenance technicians, and B2B procurement teams.
How to Read a Contactor Model Number: AC-3 Rating, Auxiliary Suffix & Coil Codes
Read guide →Type 1 vs Type 2 Coordination: Protecting AC Contactors Under Short Circuit
Read guide →Can a Contactor Cause Single-Phasing? Symptoms, Checks & Motor Protection
Read guide →How to Wire an AC Contactor: Power, Coil & Auxiliary Contacts
Read guide →How to Select the Right Surge Suppressor for AC Contactors
Read guide →Definite Purpose vs IEC AC Contactors: FLA/LRA Ratings Explained
Read guide →AC Contactor Selection & Procurement Questions
Direct answers on AC-1/AC-3/AC-4 sizing, CJX2s-W wide-voltage electronic coils, Type 1/Type 2 coordination, and OEM factory supply.
Využití What is the difference between AC-1, AC-3, and AC-4 ratings when sizing an AC contactor?
Under IEC 60947-4-1, AC-1 applies to non-inductive or slightly inductive resistive loads (heaters, lighting, distribution feeders) where switching current equals rated current. AC-3 governs standard squirrel-cage motor starting (6×In inrush) and switching off while running.
AC-4 covers severe inching, plugging, and frequent reversing where the contactor breaks full locked-rotor current (6×In). Always size motor contactors by AC-3 kW/A rating—and derate substantially for AC-4 duty to prevent contact welding.
Coil Selection When should I choose a CJX2s-W electronic-coil contactor instead of a standard laminated AC coil?
Specify VIOX CJX2s-W (9–95 A, AC/DC 24 V, 48 V, or 100–240 V wide-voltage electronic coils) on sites with unstable supply voltage, generator-backed panels, or high-density PLC cabinets where low coil holding power and hum-free operation matter.
Electronic coils eliminate coil chattering during voltage dips and allow one universal AC/DC coil SKU to replace multiple fixed-voltage inventory items across 50/60 Hz markets.
Series Comparison How do CJX2s, CJX2s High-Current, CJX2s-4P, CJX2s-M, and KCC6-M differ?
CJX2s (9–110 A, 4–55 kW) is the core 3P motor contactor; CJX2s High-Current scales to 120–800 A (55–450 kW) with built-in 2NO+2NC auxiliaries. CJX2s-4P (9–95 A, Ui 690 V) provides 4NO (04) or 2NO+2NC (08) main poles for resistive and neutral switching.
CJX2s-M (6–16 A, 3P/4P) serves tight DIN-rail or PCB/pin-type layouts, while KCC6-M (9–38 A, 2P/3P, IP40 housing) targets compact HVAC and OEM machinery panels.
Koordinace How do Type 1 and Type 2 short-circuit coordination work for AC contactors?
Under IEC 60947-4-1, Type 1 coordination permits contactor damage during a short circuit provided there is no external hazard, requiring replacement before restart. Type 2 coordination ensures the contactor remains operable after fault clearance with only minor, easily separable contact tacking.
Achieving Type 2 coordination depends on matching the VIOX AC contactor with a properly rated upstream MPCB, MCCB, or gG/aM fuse verified for the panel prospective short-circuit current.
Coil Protection Why should PLC-driven AC contactors include RC or varistor surge suppressors?
When an inductive AC contactor coil is de-energized, the collapsing magnetic field generates high-voltage switching transients that can reset nearby PLCs, trigger false sensor readings, or erode relay output contacts.
Mounting a dedicated RC or varistor surge suppressor across the coil terminals clamps these transients at the source and extends control-circuit service life.
OEM / B2B Supply Can VIOX supply OEM or private-label AC contactors with mixed coil voltages?
Yes. VIOX supports panel builders, OEM machinery manufacturers, and electrical wholesalers with factory-direct CJX2s and KCC6-M supply across mixed amperage and coil-voltage schedules, laser-marked private labeling, and IEC 60947-4-1 documentation.
Send your motor kW/A schedule, coil voltage, and pole configuration for matched factory pricing and lead times.
Potřebujete správný stykač AC?
Pojďme si to společně potvrdit.
Send your AC-3 motor kW/A rating, coil voltage, pole configuration, quantity, and target market. VIOX engineers will match the right CJX2s or KCC6-M series.
Request AC Contactor Quote