The VIOX VM6AL Series is a specialized thermomagnetic molded case circuit breaker (MCCB) designed for critical continuous-service circuits—such as fire pumps, smoke-extraction fans, hospital feeders, and emergency lighting—where nuisance thermal tripping under temporary overload is unacceptable. Covering 5 frame sizes from 160 A to 800 A (16 A–800 A rated current, 3P/4P, AC 400 V), VM6AL issues a dedicated overload alarm signal without opening the main circuit while maintaining full instantaneous magnetic short-circuit protection up to 85 kA Icu / 65 kA Ics per IEC/EN 60947-2 (Class A).
Funkce
- Dedicated overload-alarm-without-trip mechanism keeps critical fire-safety and emergency loads energized during temporary overloads.
- 5 industrial frames: VM6AL-160, VM6AL-250, VM6AL-400, VM6AL-630, and VM6AL-800 (16 A–800 A).
- Short-circuit breaking tiers C, S, M, H reaching 50 kA Icu/Ics (160–630 A) and 85 kA Icu / 65 kA Ics (800 A) at AC 400 V.
- High insulation rating (Ui 1000 V) and impulse withstand voltage (Uimp 8 kV) per IEC/EN 60947-2.
- Supports 3P and 4P (Neutral Types A, B, C, D) plus motor-protection usage code 2 up to 630 A.
- Compatible with DC3/DC6 electric motor operators, rotary handles, plug-in/draw-out bases, and internal accessory codes 00–78.
Modely
| Frame Series | Rated Current In (A) | Breaking Tiers | Poláci | Max Icu / Ics (400 V AC) |
|---|---|---|---|---|
| VM6AL-160 | 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 140, 160 A | C, S, M, H | 3P, 4P | 50 kA / 50 kA |
| VM6AL-250 | 100, 125, 140, 160, 180, 200, 225, 250 A | C, S, M, H | 3P, 4P | 50 kA / 50 kA |
| VM6AL-400 | 250, 315, 320, 350, 400 A | M, H | 3P, 4P | 50 kA / 50 kA |
| VM6AL-630 | 400, 500, 630 A | M, H | 3P, 4P | 50 kA / 50 kA |
| VM6AL-800 | 630, 700, 800 A | M, H | 3P, 4P | 85 kA / 65 kA |
Specifikace
Electrical & Breaking Capacity (AC 400 V)
| Model & Tier | Ue / Ui / Uimp | Ics (400 V) | Icu (400 V) | kategorie použití |
|---|---|---|---|---|
| VM6AL-160 C / S / M / H | 400 V / 1000 V / 8 kV | 3 / 5 / 10 / 50 kA | 5 / 8 / 20 / 50 kA | Třída A |
| VM6AL-250 C / S / M / H | 400 V / 1000 V / 8 kV | 3 / 5 / 10 / 50 kA | 5 / 8 / 20 / 50 kA | Třída A |
| VM6AL-400 M / H | 400 V / 1000 V / 8 kV | 36 / 50 kA | 50 / 50 kA | Třída A |
| VM6AL-630 M / H | 400 V / 1000 V / 8 kV | 36 / 50 kA | 50 / 50 kA | Třída A |
| VM6AL-800 M / H | 400 V / 1000 V / 8 kV | 50 / 65 kA | 65 / 85 kA | Třída A |
Outline Dimensions (mm)
| Rám | Poláci | Width W (mm) | Length L (mm) | Height Cover / Handle (mm) |
|---|---|---|---|---|
| VM6AL-160 | 3P / 4P | 90 / 120 | 155 | 68–82 / 94–108 |
| VM6AL-250 | 3P / 4P | 105 / 140 | 165 | 68–88 / 96–116 |
| VM6AL-400 | 3P / 4P | 140 / 184 | 257 | 103 / 152 |
| VM6AL-630 | 3P / 4P | 140 / 184 | 257 | 103 / 152 |
| VM6AL-800 | 3P / 4P | 210 / 280 | 275.5 | 103 / 152 |
External Accessories Compatibility
| Příslušenství | Supported Frames & Poles |
|---|---|
| Electric Motor Operation | 3P, 4P |
| Manual Rotary Handle (ZY1/ZF1/ZY2/ZF2/Z3) | 3P, 4P |
| Extension Copper Bar (P) | 3P, 4P |
| Mechanické blokování | 3P, 4P (up to 800 A) |
| Plug-in Front / Back Panel (Z2Q/Z2H/Z3Q/Z3H) | 3P, 4P (up to 800 A) |
| Draw-out Back-Panel (DR) | 400 / 630 / 800 A (3P only) |
Průvodce výběrem
| Pozice kódu | Význam | Catalog Value or Options |
|---|---|---|
| VM6AL | Sériové | Thermomagnetic MCCB with overload alarm without trip |
| 160–800 | Frame current (Inm) | 160, 250, 400, 630, 800 A |
| C / S / M / H | Breaking tier | C/S/M/H on 160–250 A; M/H on 400–800 A (M conventional) |
| Operace | Drive mechanism | Direct (blank), P1 (DC3), P2 (DC6), ZY1/ZF1/ZY2/ZF2/Z3 rotary handles |
| 3 / 4 | Poláci | 3P or 4P (Neutral options A, B, C, D) |
| 00–78 | Internal accessory code | 00 None · 08 Alarm · 10 Shunt · 18 Shunt+Alarm · 20/27 Aux · 28/29 Aux+Alarm · 30 UVT · 38 UVT+Alarm · 40/41/48 Shunt+Aux · 50 Shunt+UVT · 60–69 Multi-Aux · 70–78 UVT+Aux (DC 24/110/220 V, AC 230/400 V) |
1. Verify Fire-Code Duty
Use VM6AL on fire pumps, smoke extractors, and critical feeders requiring overload alarm without thermal disconnect.
2. Match Frame & Icu
Size from 160 A to 800 A and verify AC 400 V prospective fault current against C/S/M/H tiers up to 85 kA.
3. Wire Alarm Signal
Connect the overload alarm output to BMS or fire-control panels for immediate operator notification.
4. Select Mounting & Drive
Configure fixed, plug-in, draw-out (400–800 A 3P), rotary handle, or DC3/DC6 electric operator.
Instalace
- Confirm alarm contact wiring to the building management or fire-alarm monitoring panel during commissioning.
- Verify prospective short-circuit fault level at 400 V AC matches the selected C, S, M, or H breaking tier.
- Default internal accessory lead length is 500 mm (undervoltage release uses terminal blocks).
- Prozkoumejte celou řady VIOX MCCB or pair with VIOX ATS for emergency fire-pump transfer.
ČASTO KLADENÉ DOTAZY
How does VM6AL behave during an overload vs a short circuit?
Under overload conditions, VM6AL triggers an alarm contact without tripping the main breaker so critical fire or emergency equipment keeps running. Under a short circuit, the magnetic release trips immediately up to 85 kA Icu.
Which applications require an overload-alarm-without-trip MCCB?
Fire-fighting water pumps, smoke-exhaust fans, emergency elevators, hospital life-safety feeders, and continuous industrial process lines where unplanned shutdown poses higher risk than temporary overload.
What frame sizes and breaking capacities are available in VM6AL?
VM6AL covers five frames: 160 A, 250 A, 400 A, 630 A (up to 50 kA Icu/Ics), and 800 A (up to 85 kA Icu / 65 kA Ics at 400 V AC).
Is VM6AL available in 4-pole configurations?
Yes. All five VM6AL frames are available in 3P and 4P with Neutral Types A, B, C, and D.
Can VM6AL accept electric motor operators and rotary handles?
Yes. All frames support DC3/DC6 electric operating mechanisms (DC 24/110/220 V, AC 230/400 V), extended rotary handles, and plug-in bases; 400–800 A 3P also supports draw-out bases.
Does VM6AL support motor-protection duty?
Yes. Specify usage code 2 for motor-protection applications up to 630 A (700–800 A is power distribution only).