VIOX VSP-10C AC Type 3 Terminal Fine Surge Protection Device (18mm 2P, Uoc 10kV)

The VIOX VSP-10C is a compact 18 mm 2-pole AC Type 3 (Class III) fine surge protection device engineered for point-of-use protection of PLCs, CNC controllers, medical instruments, smart home hubs, and LED drivers. Rated Uoc 10 kV with Up 1.5 kV clamping, MOV+GDT leakage-free topology, and remote alarm contacts.

سلسلة VIOX
VSP-10C
الجهد المقنن
AC 385V (Un 220/230V)
Surge Rating
Uoc 10 kV (T3) · Up 1.5 kV
قياسي
IEC 61643-11 · Type 3 · TUV / CE

نظرة عامة

The VIOX VSP-10C is a compact 18 mm 2-pole AC Type 3 (Class III) fine surge protection device engineered for point-of-use protection of PLCs, CNC controllers, medical instruments, smart home hubs, and LED drivers. Rated Uoc 10 kV with Up 1.5 kV clamping, MOV+GDT leakage-free topology, and remote alarm contacts.

الميزات

  • IEC 61643-11 Type 3 (T3) terminal protection rated Uoc 10 kV with Up 1.5 kV fine residual clamping.
  • Single-module 18 mm width protects both Live and Neutral (2P) with zero earth leakage (MOV + GDT series).
  • High Uc 385 V AC tolerance withstands temporary utility overvoltages without nuisance tripping.
  • Includes built-in thermal disconnector and optional 11/12/14 remote alarm signaling.

المواصفات

VSP-10C Electrical & Mechanical Specifications

المعلمةالمواصفات
SPD ClassificationType 3 (Class III) Fine Protection · IEC 61643-11
Max Continuous Operating Voltage (Uc)385 V AC (Nominal Un 220/230 V AC)
Combination Wave Open-Circuit Voltage (Uoc)10 kV
مستوى حماية الجهد (Up)1.5 kV · Response Time: ≤100 ns
Leakage Current & IsccrIpe: NONE · Protective Elements: High-Energy MOV + GDT
Dimensions & Terminals18 × 90 × 67 mm (2P) · 4–16 mm² (2.0 N·m) · 35 mm DIN rail
الشهاداتTUV, CE, CB, UKCA, RoHS

VSP-10C Available Poles & Dimensions

القطبينDimensions (W × H × D)
2P (L + N + PE)18 × 90 × 67 mm (1-Module)

الأبعاد والتركيب

VIOX VSP-10C AC Type 3 Terminal Fine Surge Protection Device (18mm 2P, Uoc 10kV) Dimensional Drawing (mm)
VSP-10C Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Install as close as possible (<5 m cable distance) to sensitive terminal equipment such as PLC racks, server power supplies, or industrial HMI panels.
  • Always install downstream of an upstream Type 1 or Type 2 SPD (e.g., VIOX VSP-40).
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

الأسئلة الشائعة

When is a Type 3 SPD (VSP-10C) needed if I already have a Type 2 SPD?

When sensitive electronic loads sit more than 10 meters downstream of the main Type 2 SPD, cable inductance can cause surge voltage oscillations up to 2× Up. Installing VSP-10C directly at the equipment panel clamps residuals safely to 1.5 kV.

هل تحتاج إلى عرض سعر للمنتج؟
لنبنيها معاً.

أرسل لنا طراز المنتج، والتقييمات الفنية، والكمية، ومتطلبات الشركة المصنعة للمعدات الأصلية (OEM). سيقوم فريقنا بمراجعة طلبك والرد في غضون يوم عمل واحد.

طلب عرض أسعار