VIOX ELECTRIC
Dil

VIOX VSP-10C AC Type 3 Terminal Fine Surge Protection Device (18mm 2P, Uoc 10kV)

The VIOX VSP-10C is a compact 18 mm 2-pole AC Type 3 (Class III) fine surge protection device engineered for point-of-use protection of PLCs, CNC controllers, medical instruments, smart home hubs, and LED drivers. Rated Uoc 10 kV with Up 1.5 kV clamping, MOV+GDT leakage-free topology, and remote alarm contacts.

VIOX Serisi
VSP-10C
Anma gerilimi
AC 385V (Un 220/230V)
Surge Rating
Uoc 10 kV (T3) · Up 1.5 kV
Standart
IEC 61643-11 · Type 3 · TUV / CE

Genel Bakış

The VIOX VSP-10C is a compact 18 mm 2-pole AC Type 3 (Class III) fine surge protection device engineered for point-of-use protection of PLCs, CNC controllers, medical instruments, smart home hubs, and LED drivers. Rated Uoc 10 kV with Up 1.5 kV clamping, MOV+GDT leakage-free topology, and remote alarm contacts.

Özellikler

  • IEC 61643-11 Type 3 (T3) terminal protection rated Uoc 10 kV with Up 1.5 kV fine residual clamping.
  • Single-module 18 mm width protects both Live and Neutral (2P) with zero earth leakage (MOV + GDT series).
  • High Uc 385 V AC tolerance withstands temporary utility overvoltages without nuisance tripping.
  • Includes built-in thermal disconnector and optional 11/12/14 remote alarm signaling.

Teknik Özellikler

VSP-10C Electrical & Mechanical Specifications

ParametreŞartname
SPD ClassificationType 3 (Class III) Fine Protection · IEC 61643-11
Max Continuous Operating Voltage (Uc)385 V AC (Nominal Un 220/230 V AC)
Combination Wave Open-Circuit Voltage (Uoc)10 kV
Gerilim Koruma Seviyesi (Up)1.5 kV · Response Time: ≤100 ns
Leakage Current & IsccrIpe: NONE · Protective Elements: High-Energy MOV + GDT
Dimensions & Terminals18 × 90 × 67 mm (2P) · 4–16 mm² (2.0 N·m) · 35 mm DIN rail
SertifikalarTUV, CE, CB, UKCA, RoHS

VSP-10C Available Poles & Dimensions

KutuplarDimensions (W × H × D)
2P (L + N + PE)18 × 90 × 67 mm (1-Module)

Boyutlar ve Kurulum

VIOX VSP-10C AC Type 3 Terminal Fine Surge Protection Device (18mm 2P, Uoc 10kV) Dimensional Drawing (mm)
VSP-10C Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Install as close as possible (<5 m cable distance) to sensitive terminal equipment such as PLC racks, server power supplies, or industrial HMI panels.
  • Always install downstream of an upstream Type 1 or Type 2 SPD (e.g., VIOX VSP-40).
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

SSS

When is a Type 3 SPD (VSP-10C) needed if I already have a Type 2 SPD?

When sensitive electronic loads sit more than 10 meters downstream of the main Type 2 SPD, cable inductance can cause surge voltage oscillations up to 2× Up. Installing VSP-10C directly at the equipment panel clamps residuals safely to 1.5 kV.

Ürün Teklifi mi İstiyorsunuz?
Birlikte İnşa Edelim.

Bize ürün modelini, teknik değerleri, miktarı ve OEM gereksinimlerini gönderin. Ekibimiz başvurunuzu inceleyecek ve bir iş günü içinde yanıt verecektir.