VIOX ELECTRIC
Ngôn ngữ

VIOX VSP-60 / VSP-80 / VSP-100 / VSP-160 High-Capacity AC Type 2 SPD (60–160kA)

The VIOX VSP-60, VSP-80, VSP-100, and VSP-160 series deliver heavy-duty AC Type 2 surge protection from Imax 60 kA up to 160 kA (8/20 μs) for main industrial switchboards, exposed overhead-line feeders, and high-keraunic commercial installations. Built with high-energy MOV stacks, <25 ns response, and optional remote signaling across 385 V and 440 V AC networks.

Dòng VIOX
VSP-60 / VSP-80 / VSP-100 / VSP-160
Điện áp định mức
AC 385V / 440V
Surge Rating
In 30–100 kA · Imax 60–160 kA
Chuẩn
IEC 61643-11 · TUV / CE / CB

Tổng quan

The VIOX VSP-60, VSP-80, VSP-100, and VSP-160 series deliver heavy-duty AC Type 2 surge protection from Imax 60 kA up to 160 kA (8/20 μs) for main industrial switchboards, exposed overhead-line feeders, and high-keraunic commercial installations. Built with high-energy MOV stacks, <25 ns response, and optional remote signaling across 385 V and 440 V AC networks.

Đặc trưng

  • Four heavy-duty Type 2 discharge tiers: VSP-60 (In 30 / Imax 60 kA), VSP-80 (40/80 kA), VSP-100 (60/100 kA), and VSP-160 (100/160 kA).
  • Rated for Uc 385 V and 440 V AC to handle harsh industrial mains and transformer secondary fluctuations.
  • Fast <25 ns clamping with Up ≤2.2–3.0 kV and built-in thermal disconnection mechanism.
  • Supports 1P, 1+NPE, 2P, 3P, 4P, and 3+NPE wiring across TN-S, TN-C, and TT power systems.
  • Coordinated with VIOX VSP-SSD80 and VSP-SSD160 dedicated SPD backup disconnectors.

Thông số kỹ thuật

VSP-60 / VSP-80 / VSP-100 / VSP-160 Electrical & Mechanical Specifications

Tham sốĐặc điểm kỹ thuật
SPD ClassificationType 2 (Class II) Heavy-Duty · IEC 61643-11 / EN 61643-11
Max Continuous Operating Voltage (Uc)385 V / 440 V AC
Nominal Discharge Current (In, 8/20 μs)VSP-60: 30 kA · VSP-80: 40 kA · VSP-100: 60 kA · VSP-160: 100 kA
Max Discharge Current (Imax, 8/20 μs)VSP-60: 60 kA · VSP-80: 80 kA · VSP-100: 100 kA · VSP-160: 160 kA
Mức bảo vệ điện áp (Up)VSP-60: ≤2.2/2.5 kV · VSP-80/100/160: ≤2.5/3.0 kV
Response Time (tA)<25 ns
Recommended Backup SCBVSP-SSD80 (for 60–80 kA) · VSP-SSD160 (for 100–160 kA)
Conductor Cross-SectionLine ≥10–16 mm² · Earth ≥16 mm² · Terminals 6–25 mm² (2.5 N·m)
Housing & EnvironmentPBT / PA UL94 V-0 · IP20 · -40°C to +70°C · 35 mm DIN rail
Chứng nhậnTUV, CE, CB, UKCA, RoHS

VSP-60 / VSP-80 / VSP-100 / VSP-160 Available Poles & Dimensions

Model Tier1P1+NPE / 2P3P4P / 3+NPE
VSP-60 / VSP-8018 × 90 × 67 mm36 × 90 × 67 mm54 × 90 × 67 mm72 × 90 × 67 mm
VSP-100 / VSP-16036 × 90 × 68 mm72 × 90 × 68 mm108 × 90 × 68 mm144 × 90 × 68 mm

Kích thước & Lắp đặt

VIOX VSP-60 / VSP-80 / VSP-100 / VSP-160 High-Capacity AC Type 2 SPD (60–160kA) Dimensional Drawing (mm)
VSP-60 / VSP-80 / VSP-100 / VSP-160 Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Pair VSP-80 with VIOX VSP-SSD80 and VSP-100/160 with VIOX VSP-SSD160 so backup breakers never nuisance-trip during 80–160 kA surge events.
  • Use ≥16 mm² copper earth bonding cable directly to the main equipotential bonding bar.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

Câu hỏi thường gặp

When should I specify 80–160kA Type 2 instead of standard 40kA?

Use VSP-60 through VSP-160 at main distribution boards fed by overhead lines or in tropical/high-lightning-density regions where repeated high-energy induced surges quickly exhaust 40 kA cartridges.

Cần báo giá sản phẩm?
Hãy cùng chúng tôi thực hiện dự án này.

Gửi cho chúng tôi mã sản phẩm, các định mức kỹ thuật, số lượng và yêu cầu OEM. Đội ngũ của chúng tôi sẽ xem xét ứng dụng của bạn và phản hồi trong vòng một ngày làm việc.

Yêu cầu báo giá